The Yokogawa AAT141-S00 is a 16-channel isolated thermocouple and millivolt input module designed for FIO systems within CENTUM VP field control stations. It functions as a signal converter by inputting field temperature and voltage signals into internal data for the Field Control Station (FCS). The AAT141-S00 module receives signals from thermocouple types J, K, E, B, R, S, T, and N, as well as mV voltage spans ranging from -100 to 150 mV and -20 to 80 mV. It supports dual-redundant configuration and connects externally via a pressure clamp terminal block.

Features

  • 16 isolated input channels for thermocouple and mV signals.
  • Software-selectable TC/mV input types individually configured for CH1 to CH16.
  • Dual-redundant configuration capability.
  • Dedicated pressure clamp terminal external connection interface.
  • Software-configurable burnout detection (UP/DOWN/Not available) for all channels.

Applications

  • Process temperature monitoring using thermocouples.
  • Millivolt analog input signal interfacing in CENTUM VP FIO DCS environments.
  • High-reliability industrial control systems requiring isolated I/O modules.

Ordering Information

Model Suffix Codes Option Codes Description
AAT141     TC/mV Input Module (16-channel, Isolated)
Suffix -S   Standard type
  0   With no explosion protection
  0   Basic type

Technical Specifications

Category Item Specification
Basic Specifications Manufacturer Yokogawa
  Model AAT141-S00
  Number of Input Channels 16, isolated
Input Specifications Input Signal

TC: JIS C1602:1995, IEC584:1995 Type J, K, E, B, R, S, T, N


 

mV: -100 to 150 mV, -20 to 80 mV

  Switching Input Signals TC/mV can be set individually for CH1 to CH16
  Allowable Input Voltage +/-5 V
  Input Resistance (Power ON/OFF) 2 MOhm or larger
Performance Accuracy

+/-30 uV (TC)


 

+/-80 uV for span (-100 to 150 mV)


 

+/-30 uV for span (-20 to 80 mV)

  Reference Junction Compensation Accuracy Within +/-1 degC (varies depending on installation and ambient temperature)
  Allowable Total Resistance 1000 Ohm or less (signal source plus wiring)
  Effect of Signal Source Resistance +/-20 uV per 1000 Ohm (+/-40 uV in dual-redundant configuration)
  Temperature Drift

+/-80 uV/10 degC (-100 to 150 mV input)


 

+/-30 uV/10 degC (TC/-20 to 80 mV input)

  Data Update Period 1 s
  Burn-out Detection All channels can be set together (Not available/available UP/DOWN), Detection time: 60 s
Electrical & Insulation Withstanding Voltage Between input and system: 1500 V AC, for 1 minute
  Maximum Current Consumption 450 mA (5 V DC)
Physical Specifications Weight 0.2 kg
  External Connection Pressure clamp terminal

Installation Guidelines

  • Use a non-ground type thermocouple (TC) because the device is an isolated type module; using ground type TC on multiple channels causes temperature errors due to multi-point ground.
  • Ensure proper installation onto supported ESB, Optical ESB, or ER bus node units.
  • Maintain matching wiring resistance for signal cables to ensure measurement accuracy.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Yokogawa AAT141-S00 CENTUM VP TC/mV Input Module (16-channel, Isolated)

What input signal types are supported by the module?

The module supports thermocouple types J, K, E, B, R, S, T, and N, as well as mV voltage inputs ranging from -100 to 150 mV and -20 to 80 mV.

Why must non-ground type thermocouples be used with this module?

Because the module is an isolated type, using a ground type thermocouple across multiple channels causes temperature measurement errors due to multi-point grounding.

What is the maximum current consumption for the device?

The maximum current consumption is 450 mA at 5 V DC.

الشحن السريع العالمي

  • التوصيل العادي: من 4 إلى 6 أيام عمل عبر DHL وFedEx وUPS.
  • الشحن السريع: شحن في نفس اليوم للطلبات المتوفرة في المخزون والمقدمة قبل الساعة 2:00 ظهرًا (بتوقيت GMT+8).
  • تغطية عالمية: نخدم أكثر من 150 دولة، بما في ذلك التوصيل السريع إلى السعودية والإمارات.

الإرجاع والضمان

  • ضمان لمدة 30 يومًا: يتم قبول الإرجاع للمنتجات المتوفرة في المخزون في عبوتها الأصلية المختومة من المصنع.
  • ضمان لمدة 12 شهرًا: كل مكون صناعي مدعوم بضماننا الفني المهني.

يتم معالجة الطلبات وتسليمها من الاثنين إلى الجمعة (باستثناء العطلات الرسمية).


للاطلاع على الأهلية الكاملة، ورسوم إعادة التخزين، وتفاصيل الإرجاع الدولي، يرجى مراجعة موقعنا الرسمي سياسة الاسترداد والإرجاع .

TECHNICAL SPECIFICATIONS

Country of origin
اليابان

المنتجات التي تم عرضها مؤخرًا

المعرفة التقنية

تحديث واجهات المستخدم البشرية لنظام Bailey INFI 90 Symphony العاملة على OpenVMS Alpha

دليل عملي لاستبدال محطات تشغيل Bailey Symphony القديمة التي تعمل على OpenVMS Alpha. يقارن بين محاكاة Alpha، والترحيل إلى OpenVMS على x86، وإعادة بناء النظام الأساسي باستخدام OPC، والتحديث المرحلي...

لماذا تُعدّ بيانات الصيانة ضرورية للموثوقية الصناعية

تربط بيانات الصيانة بين أوامر العمل وإشارات المستشعرات وسجل الأصول والتكاليف ومعرفة الفنيين. وعند استخدامها بشكل جيد، فإنها تحسّن التخطيط والموثوقية والصيانة التنبؤية والتحكم في قطع الغيار وقرارات...

مشغلات كهربائية مصممة لتحل محل أنظمة القدرة بالموائع: دليل عملي للأتمتة الصناعية

تشرح هذه المقالة كيف تُحدث المشغلات الكهربائية المتكاملة، مثل سلسلة e-Actuator من SMC، تحولًا في التحكم بالحركة الصناعية من خلال استبدال الأنظمة الهوائية والهيدروليكية التقليدية. وتسلّط الضوء على...

العمليات الحسابية باستخدام OpenPLC لتطبيقات الأتمتة الصناعية

تشرح هذه المقالة كيفية إجراء أنظمة PLC للعمليات الرياضية الأساسية مثل الجمع والطرح والضرب والقسمة وحساب باقي القسمة والأسّ ضمن الأتمتة الصناعية. وتوضح كيفية تحويل كتل الوظائف هذه لإشارات المستشعر...

المنطق البولياني المتقدم مع برمجة وحدات التحكم المنطقية القابلة للبرمجة (PLC) باستخدام مخططات الكتل الوظيفية (FBD): تطبيقات صناعية عملية تتجاوز المنطق الأساسي

تشرح المقالة العديد من وظائف المنطق البولياني المتقدمة المستخدمة في برمجة وحدات التحكم المنطقية القابلة للبرمجة (PLC)، بما يتجاوز عمليات AND وOR وNOT الأساسية. كما توضح كيفية تطبيق أدوات مثل جداول...

المنطق البولياني في برمجة وحدات التحكم المنطقية القابلة للبرمجة: فهم البوابات المنطقية في مخططات الكتل الوظيفية (FBD)

المنطق البولياني هو أساس كل برنامج من برامج المتحكم المنطقي القابل للبرمجة (PLC). فمن أنظمة التحكم البسيطة في الآلات إلى أنظمة الأتمتة الصناعية المعقدة، تحدد البوابات المنطقية كيفية استجابة المتحكمات...