1 of 1

Siemens SIMOVERT MASTERDRIVES du/dt Filter 6SE7016-2FB87-1FD0-Z

Siemens SIMOVERT MASTERDRIVES du/dt Filter 6SE7016-2FB87-1FD0-Z

Only 6 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6SE7016-2FB87-1FD0-Z

  • Country of origin:Germany

  • Product Type: Filters

  • Barcode: 85044095

  • Payment: T/T, Western Union

  • Weight: 20g

  • Dimensions: 48.30cm x 40.60cm x 35.60cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The 6SE7016-2FB87-1FD0-Z is a du/dt filter from the SIMOVERT MASTERDRIVES series, manufactured by Siemens. This filter is designed to mitigate the steep voltage rise times (du/dt) generated by Pulse Width Modulation (PWM) in variable frequency drives. By limiting these voltage spikes, the filter protects motor insulation and cable systems from premature degradation, extending the lifespan of the drive-motor assembly in demanding industrial applications. Rated for both 380-460V AC (at 6.1A) and 500-575V AC (at 6.2A) systems, this robust component is a critical solution for maintaining process reliability.

Features

  • Voltage Spike Suppression: Effectively reduces the du/dt rate to protect motor windings and insulation.
  • Dual-Voltage Capability: Suitable for 380-460V AC and 500-575V AC three-phase power systems.
  • Masterdrives Compatibility: Specifically engineered for integration within the Siemens SIMOVERT MASTERDRIVES ecosystem.
  • Industrial Robustness: Designed to withstand the rigors of heavy-duty manufacturing environments.

Technical Specifications

Attribute Specification
Manufacturer Siemens
Product Range SIMOVERT MASTERDRIVES
Model 6SE7016-2FB87-1FD0-Z
Product Type du/dt Filter
Rated Current (380-460V) 6.1A
Rated Current (500-575V) 6.2A
Weight 20.00kg
Dimensions 48.30 x 40.60 x 35.60 cm
Commodity Code 85044095
PLM Product Phase Obsolete

Installation Guidelines

  • Ventilation: Due to the power dissipated by the filter, ensure it is installed in an enclosure with adequate forced-air ventilation.
  • Proximity: Install the filter as close to the drive output as possible to minimize the impact of cable length on voltage reflections.
  • Grounding: Secure a solid, low-impedance connection between the filter chassis and the system ground plate to ensure effective EMI shielding.
  • Cable Selection: Use shielded power cables between the filter and the motor to minimize radiated electromagnetic noise.
  • Safety: Because this is an obsolete unit, ensure all mounting brackets and electrical terminals are inspected for integrity before integration, and always perform installation with the power locked out.

What is the function of a du/dt filter in a drive system?

A du/dt filter reduces the steepness of voltage rise times from a PWM drive, protecting motor insulation and reducing cable stress.

What voltage ranges is this filter compatible with?

It is rated for three-phase systems of 380-460V AC and 500-575V AC.

Is this product still in active production?

No, the 6SE7016-2FB87-1FD0-Z is currently classified as obsolete.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Maye Güc Sistemlərini Əvəz Etmək Üçün Dizayn Edilmiş Elektrik Aktuatorları: Praktik Sənaye Avtomatlaşdırma Bələdçisi

Bu məqalə SMC-nin e-Actuator seriyası kimi inteqrasiya olunmuş elektrik aktuatorlarının ənənəvi pnevmatik və hidravlik sistemləri əvəz etməklə sənaye hərəkət nəzarətini necə dəyişdirdiyini izah edir....

Sənaye Avtomatlaşdırma Tətbiqləri üçün OpenPLC ilə Riyazi Əməliyyatlar

Bu məqalə PLC sistemlərinin sənaye avtomatlaşdırmasında toplama, çıxma, vurma, bölmə, modulo və qüvvətə qaldırma kimi əsas riyazi əməliyyatları necə yerinə yetirdiyini izah edir. Məqalədə bu...

FBD PLC Proqramlaşdırmada Təkmil Boolean Məntiqi: Əsas Məntiqdən Kənar Praktiki Sənaye Tətbiqləri

Məqalə, PLC proqramlaşdırmada əsas AND, OR və NOT əməliyyatlarından kənar istifadə olunan bir neçə inkişaf etmiş Boolean məntiq funksiyalarını izah edir. O, Həqiqət cədvəlləri, çoxlayıcılar, impuls...

PLC Proqramlaşdırmada Boolean Məntiqi: FBD Məntiq Qapılarını Anlamaq

Boolean məntiqi hər bir PLC proqramının əsasını təşkil edir. Sadə maşın idarəetmələrindən mürəkkəb sənaye avtomatlaşdırma sistemlərinə qədər, məntiq qapıları nəzarətçilərin dəyişən girişlərə və...