1 от 1

Mitsubishi Electric FR-A820-22K-1 FR-A800 Inverter

Mitsubishi Electric FR-A820-22K-1 FR-A800 Inverter

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-A820-22K-1

  • Country of origin:Съединени щати

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 15000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

Managing heavy-duty motor control within demanding industrial environments is the primary role of the Mitsubishi Electric FR-A820-22K-1 variable frequency drive. Operating on a 200V class three-phase input, this premium FR-A800 Series inverter delivers an ND (Normal Duty) rated capacity of 22 kW, making it suitable for high-torque applications. Equipped with an FM-type monitor terminal and integrated RS-485 serial communication, the unit enables real-time drive diagnostics and integration into centralized control networks. Its robust mechanical housing is built to withstand rigorous factory conditions while optimizing thermal dissipation.

Features

  • Advanced Vector Control: Supports Real Sensorless Vector Control (RSV) and full closed-loop vector control for induction and permanent magnet (PM) motors.
  • Dual Network Capability: Built-in RS-485 communication protocols with easy expansion paths to CC-Link, Profibus-DP, DeviceNet, and EtherCAT.
  • Excellent Torque Performance: Delivers high starting torque (200% at 0.5 Hz under Real Sensorless Vector Control).
  • Integrated PLC Functionality: Allows custom logic programming directly within the drive to reduce external controller requirements.
  • Long-Life Design: Built with high-specification capacitors and cooling fans rated for a 10-year design life.

Applications

  • Heavy-duty material handling systems and industrial cranes.
  • High-capacity fans, blowers, and industrial ventilation systems.
  • Positive displacement pumps and wastewater processing equipment.
  • Extruders, mixers, and processing machinery in chemical and plastics plants.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Mitsubishi Electric
Model Number FR-A820-22K-1
Series FR-A800 Series
Voltage Class 3-Phase 200V Class (200V to 240V AC, 50Hz/60Hz)
Rated Capacity (ND) 22 kW
Communication Interface RS-485 / FM Type terminal configuration
Enclosure Rating Open type (IP00)
Cooling Method Forced air cooling
Operating Temperature -10 degC to 50 degC (non-freezing)
Actual Net Weight 15.0 kg
Shipping Weight (Calculated) 20.0 kg

Connections and Interfaces

Terminal / Port Functional Assignment
R/L1, S/L2, T/L3 Three-phase AC power input terminals
U, V, W Three-phase AC motor output terminals
FM Pulse train/analog monitor output terminal
SD Common terminal for control circuits and RS-485 isolation
TXD+/RXD+ RS-485 differential communication channels

Empirical Engineering Insights

Alternative Models & Compatibility

When migrating legacy systems from the older FR-A720-22K series to the FR-A820-22K-1, ensure you map the terminal configurations accurately. While the mounting dimensions are highly compatible, parameter structures differ. Use FR Configurator2 software to perform a automated parameter conversion. Pay careful attention to the FM terminal output settings; the standard FM pulse frequency scaling may require adjustments to match your existing analog panel meters.

Application Pitfalls & Engineering Notes

Under continuous high-load applications, this 15 kg inverter generates considerable thermal dissipation. Enclosure design must accommodate at least 150W of continuous heat output from the drive’s internal heat sink. Maintain a minimum clearance of 10 cm above and below the drive. For enclosed panel installations, we recommend routing the heatsink portion through the back of the panel (external mounting) to preserve the interior thermal budget of the control cabinet.

Commissioning & Wiring Tips

To eliminate electromagnetic interference (EMI) on the RS-485 communication bus, always utilize shielded twisted-pair (STP) cabling. Connect the shield braid strictly to the physical ground terminal at the drive end only. Avoid routing control circuit wiring in the same conduit or parallel cable tray as the main R/L1-S/L2-T/L3 input lines. Always maintain a minimum separation distance of 30 cm between high-power supply cables and low-voltage control signals.

Installation Guidelines

CRITICAL WARNING: Ensure all main AC power lines feeding the system are fully de-energized and locked out before attempting any physical wiring. Wait a minimum of 10 minutes after power-off to allow the internal DC bus capacitors to discharge fully. Verify that the "CHARGE" LED on the front faceplate is completely extinguished and measure DC bus voltage across terminals P/+ and N/- to confirm it is below 20V DC before starting work.
1

Mount the inverter vertically on a non-flammable backplate (such as steel or concrete) using the specified M8 mounting bolts torqued to 4.0 N-m.

2

Connect the physical protective earth (PE) ground conductor to the dedicated grounding terminal prior to connecting any primary input lines.

3

Wire the main three-phase power input to terminals R/L1, S/L2, and T/L3. Ensure proper phase rotation matches your control sequence.

4

Connect the motor leads to terminal outputs U, V, and W. Do not connect power lines to these terminals as this will cause catastrophic drive failure.

What does the -1 suffix in the model code FR-A820-22K-1 specify?

The -1 suffix indicates the FM-type control terminal specification, which uses terminal FM for pulse train and analog outputs along with RS-485 communication protocols.

What is the recommended discharge waiting time before servicing this drive?

Always wait at least 10 minutes after disconnecting the mains power and verify that the physical charge lamp on the drive's display has completely turned off.

Does this VFD support closed-loop vector control?

Yes, closed-loop vector control is fully supported when the drive is configured with an optional encoder feedback card such as the FR-A8AP plugin module.

Can this unit run on a single-phase 200V input supply?

No, this standard 22 kW model is rated for a continuous three-phase 200V to 240V AC input. Running it on single-phase supply is not recommended and will lead to an undervoltage trip under load.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Country of origin
Съединени щати

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...