1 von 6

ABB FPBA-01 ACS Series PROFIBUS DP Adapter Module

ABB FPBA-01 ACS Series PROFIBUS DP Adapter Module

Nur noch 4 Artikel auf Lager verfügbar
  • Hersteller: ABB

  • Produkt-Nr.: FPBA-01

  • Herkunftsland:Schweden

  • Produkttyp: PROFIBUS Adapter Modules

  • Strichcode: 85044095

  • Zahlung: T/T, Western Union

  • Gewicht: 100g

  • Abmessungen: 7.60 cm x 7.60 cm x 2.50 cm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Anzahl
Vollständige Details anzeigen

Description

Establishing high-performance cyclic and acyclic data exchange between industrial control networks and variable speed drives, the ABB FPBA-01 PROFIBUS DP communication adapter module provides seamless integration into distributed control architectures. This interface module slides directly into the drive slot, enabling standard PROFIdrive or ABB Drives communication profiles to command, monitor, and configure parameters on compatible frequency converters. Operating with 16-bit word lengths, it ensures reliable signal transmission under demanding electromagnetic conditions typical of industrial plant floors.

Key Technical Features

  • Multi-Protocol Support: Full compliance with both PROFIBUS DP-V0 and DP-V1 standards, allowing cyclic process data exchange and acyclic parameter configuration.
  • Adaptive Baud Rate Detection: Automatically locks onto network speeds ranging from 9.6 kbit/s up to 12 Mbit/s, eliminating manual transmission rate configurations.
  • Versatile Control Profiles: Native support for the standard PROFIdrive profile as well as the proprietary ABB Drives profile for system flexibility.
  • Direct Slot Integration: Compact physical form factor designed to mount inside the drive housing, receiving internal control power directly from the host drive.

Industrial Applications

  • Continuous Process Environments: Connecting variable speed pump and fan drives in water/wastewater facilities to centralized PLCs.
  • Automated Material Handling: Synchronization of conveyor speed controllers in packaging and logistics distribution lines.
  • Machinery Manufacturing: High-density multi-axis machinery configurations using ACS355 drive blocks controlled via a centralized Siemens master controller.

Technical Specifications Table

Parameter Specification Value / Limit
Manufacturer ABB
Model Identifier FPBA-01
Internal Part Code 68469325
Host Drive Compatibility ACS355, ACS350, ACS850, ACQ810, ACS880, ACS580 Series
Communication Protocol PROFIBUS DP-V0 and DP-V1
Baud Rate Range 9.6 kbit/s to 12 Mbit/s (Auto-detecting)
Connection Interface 9-pin D-sub (female) connector
Current Consumption Max 80 mA at 24 VDC (supplied from host drive)
Commodity Code 85044095
Dimensions 7.60 cm x 7.60 cm x 2.50 cm
Net Weight 0.10 kg

Connections and Pin Assignments

The fieldbus physical layer utilizes a 9-pin Sub-D female block configured as follows:

Pin Number Signal Name Description
1 SHLD Chassis and Cable Shield Connection
3 RxD/TxD-P (B-Line) Positive Data Transmission (Red Wire)
5 DGND Data Ground (Reference potential)
6 VP +5 VDC Power supply for termination resistors
8 RxD/TxD-N (A-Line) Negative Data Transmission (Green Wire)

Empirical Engineering Insights

Alternative Models & Compatibility

The FPBA-01 acts as a universal communication adapter for multiple series of ABB drives. However, some legacy ACS350 drives require a dedicated firmware revision level to map DP-V1 acyclic blocks correctly. Check parameter group 51 (Fieldbus Parameter Group) after hardware discovery to confirm that the driver version is recognized by the VFD main board.

Application Pitfalls & Engineering Notes

A common cause of bus faults during system startups is the lack of proper network termination on physical line ends. If the FPBA-01 sits at the physical end of the PROFIBUS segment, a SUB-D connector containing integrated termination switches must be used, and the switch must be toggled to 'ON'. Ensure that this termination connector receives power from Pin 6 (+5V) and Pin 5 (DGND) on the FPBA-01 module.

Commissioning & Wiring Tips

When compiling the master PLC database, ensure the correct GSD configuration file is loaded (typically ABB_090F.GSD). After altering parameter values in Group 51, a parameter refresh is mandatory. Trigger Parameter 51.27 (FBA PAR REFRESH) or perform a complete drive power cycle to commit the node address changes to active memory.

Installation Guidelines

CRITICAL SAFETY WARNING

Ensure the host drive is fully de-energized. Wait a minimum of 5 minutes after switching off the main incoming power supply to allow the DC bus capacitors to discharge completely. Use a calibrated multimeter to confirm zero voltage at the drive terminals before inserting or removing the communication card.

1
Align the male multi-pin header on the rear of the FPBA-01 adapter with the corresponding interface option slot on the host drive control panel area.
2
Carefully press the module in place until the retaining plastic tabs engage with the drive frame to secure physical placement.
3
Tighten the integrated mounting/grounding screw to establish reliable chassis grounding and prevent vibration-induced disconnections.
4
Insert the standard 9-pin Sub-D PROFIBUS connector and secure it using the thumb screws. Route the fieldbus cable far from high-power phase wiring.
Loading product navigation…

Can the FPBA-01 module be hot-swapped while the host drive is powered?

No. Removing or inserting the module while control power is applied to the drive can permanently damage the internal interfaces of both the drive and the adapter module.

How is the PROFIBUS node address assigned for this module?

The node address is set using Group 51 parameters (specifically parameter 51.02) via the drive's control panel or drive commissioning software. Address configurations from 1 to 125 are supported.

Does the FPBA-01 require an external 24V power supply to work?

No. The module is directly powered through the drive’s internal slot connection, drawing a maximum of 80 mA of internal power.

What is the differences between DP-V0 and DP-V1 operation on the FPBA-01?

DP-V0 supports cyclic data exchange, such as control words, status words, and speed references. DP-V1 compatibility adds acyclic read/write commands, enabling advanced parameter modification directly from the PLC.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage per DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) eingehen.
  • Weltweite Abdeckung: Wir beliefern über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden von Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabebedingungen lesen Sie bitte unsere offiziellen Rückerstattungs- & Rückgaberecht .

TECHNICAL SPECIFICATIONS

Country of origin
Schweden

Kürzlich angesehene Produkte

Technisches Wissen

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Die boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...

Factory I/O: Ein modernes PLC-Simulationswerkzeug für die Ausbildung in der Industrieautomatisierung

Factory I/O revolutioniert die SPS-Ausbildung, indem es immersive 3D-Industriesimulationen für Studenten, Ingenieure und Wartungsteams bereitstellt. Die Plattform überbrückt die Lücke zwischen...