1 von 1

BECKHOFF ER2349-0021 EtherCAT Box 16-Channel Digital I/O Module

BECKHOFF ER2349-0021 EtherCAT Box 16-Channel Digital I/O Module

Nur noch 10 Artikel auf Lager verfügbar
  • Hersteller: BECKHOFF

  • Produkt-Nr.: ER2349-0021

  • Herkunftsland:Deutschland

  • Produkttyp: EtherCAT I/O Modules

  • Zahlung: T/T, Western Union

  • Gewicht: 450g

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

Decentralized field installation without a control cabinet is streamlined with the ER2349-0021 EtherCAT Box. This robust, IP67-rated module handles up to 16 digital signals, each of which is independently configurable as either an input or an output. Operating on the high-performance EtherCAT protocol, it interfaces directly with field sensors and actuators via compact M8 screw-type connection sockets. Its versatile design is optimized for space-constrained industrial setups requiring reliable, high-density I/O routing directly in harsh environments.

Features

  • 16 digital channels, freely configurable as inputs or outputs to match dynamic field requirements.
  • EtherCAT high-speed fieldbus communication with integrated M8 shielded, screw-type interfaces.
  • Robust housing with IP65, IP66, and IP67 protection ratings conforming to EN 60529, suitable for wet, dusty, or wet-cleaning environments.
  • Individual short-circuit protection on each channel to safeguard connected sensors and actuators.
  • Integrated 500 V electrical isolation between the fieldbus logic and load supply.

Applications

  • Automotive manufacturing assembly lines and robotic work cells.
  • Packaging, sorting, and material handling systems requiring decentralized, on-machine IP67 modules.
  • Special-purpose machine building and heavy-duty process automation configurations.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model ER2349-0021
Protocol EtherCAT
Bus Interface 2 x M8 socket, shielded, screw type
Specification Standards EN 61131-2, type 1/3
Number of Channels 16 digital inputs or outputs, configurable
Input/Output Connections M8 x 1, 3-pin, a-coded
Input Filter Time 10 us
"0" Signal Voltage -3 to +5 V
"1" Signal Voltage 11 to 30 V, 6 mA input current (EN 61131-2, type 3)
Sensor Supply From load supply voltage, max. 0.5 A, short-circuit proof in total
Load Type Ohmic, inductive, lamp load
Rated Load Voltage 24 V DC (-15% / +20%)
Max. Output Current 0.5 A per channel, individually short-circuit proof, sum 4 A
Switching Times Typical TON: 60 us, typical TOFF: 300 us
Short-Circuit Current Typical 1.5 A
Auxiliary Power Current Typical 20 mA + load
Current Consumption from US 130 mA
Power Supply Connection Feed: 1 x M8 male socket, 4-pin; Downstream connection: 1 x M8 female socket, 4-pin
Electrical Isolation 500 V
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Weight Approx. 450 g

Connections and Interfaces

Connection Interface Specification / Type
EtherCAT Bus 2 x M8 socket, shielded, screw-type connection
Digital Inputs/Outputs 16 x M8 x 1, 3-pin, a-coded
Power Feed 1 x M8 male socket, 4-pin
Downstream Power 1 x M8 female socket, 4-pin

Installation Guidelines

Ensure the ER2349-0021 EtherCAT Box is securely mounted to a flat surface using the integrated screw mounting holes. Tighten all M8 connection cables to their specified torque ratings to preserve the unit's IP65/66/67 physical protection barrier. Route control network cabling and high-power electrical drive lines in separate paths to minimize electromagnetic interference. Ground the bus system via the integrated earthing connection point.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

Are the digital channels on the ER2349-0021 inputs or outputs?

The 16 digital channels on the ER2349-0021 are freely configurable, allowing each individual channel to be configured as either a digital input or a digital output.

What is the physical protection rating of the ER2349-0021?

It features an IP65/66/67 rating conforming to EN 60529, making it highly resistant to dust, water jets, and temporary immersion, suitable for direct machine mounting without a control cabinet.

What physical connector types does the module use for communication and power?

The EtherCAT bus utilizes 2 x M8 shielded screw-type sockets, the digital I/O uses M8 3-pin a-coded connections, and the power feed/downstream interfaces use 4-pin M8 sockets.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe als Ersatz für Flüssigkeiten: Praktisches Tutorial

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...