Description

Designed for decentralized industrial automation environments, the Beckhoff IP2301-B310 is a rugged, field-mountable I/O module operating on the PROFIBUS DP network protocol. This unit features a combined configuration of four digital inputs and four digital outputs, allowing for local integration of sensors and actuators directly on processing machinery. By eliminating the necessity for protective control cabinets, this Fieldbus Box optimizes installation footprints and significantly reduces field-wiring complexity.

The module communicates at high speeds with automatic baud rate detection up to 12 Mbaud, ensuring deterministic performance within time-critical automation systems. It features M8 interfaces for robust signal distribution and an M12 B-coded connection for secure PROFIBUS network coupling.

Features

  • Four 24 V DC digital inputs with integrated 3.0 ms input filtering.
  • Four 24 V DC digital outputs rated at 0.5 A per channel, suitable for resistive, inductive, and lamp loads.
  • Automatic baud rate detection up to 12 Mbaud for seamless integration into PROFIBUS DP networks.
  • Individually short-circuit proof outputs with transient protection.
  • Rugged polyamide housing (PA6) offering IP65, IP66, and IP67 protection classes.
  • Direct machine mounting with integrated dual-point fixing slots.

Applications

  • Automotive assembly and conveyor systems.
  • Packaging, sorting, and material handling lines.
  • Decentralized machine tool control.
  • Food and beverage processing plants requiring washdown-rated components.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Part Number / Model IP2301-B310
Product Type Fieldbus Box Digital I/O Module
Fieldbus System PROFIBUS DP
Baud Rates 9.6 kbaud to 12 Mbaud (automatic detection)
Number of Channels 4 digital inputs + 4 digital outputs
Input Filter Time 3.0 ms
"0" Signal Voltage -3 to +5 V
"1" Signal Voltage 11 to 30 V, 6 mA input current (EN 61131-2, type 2)
Output Current 0.5 A per channel (short-circuit proof)
Control Voltage 24 V DC (-15% / +20%)
Power Supply Connections Feed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)
Bus Connection Interface 1 x M12 socket, 5-pin, B-coded
Dimensions (W x H x D) 30 mm x 175 mm x 26.5 mm
Housing Material PA6 (polyamide)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Class IP65/66/67 (conforms to EN 60529)
Weight 2.0 kg (including typical packaging)

Connections and Interfaces

Interface Connection Connector Type Function / Assignment
Digital Inputs & Outputs M8 screw-type Channel connection for 4 sensors and 4 actuators
PROFIBUS DP Interface M12 socket, 5-pin, B-coded Primary bus communication network link
Power Supply Input M8 male, 4-pin 24 V DC control and load power input feed
Power Supply Output M8 female, 4-pin 24 V DC downstream power feed to subsequent modules

Installation Guidelines

  • Mount the module vertically or horizontally on flat machinery surfaces using two 3.5 mm mounting holes designed for M3 fasteners.
  • To maintain the IP65/66/67 ingress protection rating, ensure all unused M8 and M12 ports are sealed with approved protective caps.
  • Route communication cables separately from high-voltage AC lines to prevent electromagnetic interference.
  • Verify that the cumulative current draw of the sensor supply and outputs does not exceed the module's specified power connection limits.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What is the ingress protection rating of the Beckhoff IP2301-B310?

The module is rated at IP65, IP66, and IP67 under standard EN 60529, meaning it is dust-tight and highly resistant to water jets and immersion, allowing cabinet-free machine mounting.

Does the IP2301-B310 support automatic baud rate detection?

Yes, it automatically detects transmission speeds on the PROFIBUS DP network up to 12 Mbaud.

What is the maximum current capacity per output channel?

Each of the 4 digital outputs can supply up to 0.5 A, and every channel is individually protected against short circuits.

What connection types are used for the sensors and actuators?

The digital inputs and outputs on the IP2301-B310 utilize rugged, screw-type M8 connections.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...