Engineered for high-density space conservation in control cabinets, the BECKHOFF KL1889 is a High-Density (HD) Bus Terminal featuring sixteen digital inputs in a compact 12 mm housing width. Operating with negative switching (sink) logic, this module incorporates 1-wire connection technology, allowing direct connection of sensors and signals to the process image without excessive terminal blocks. Designed for seamless integration into K-bus networks, the KL1889 enables efficient signal acquisition in restricted spaces while simplifying wiring and minimizing hardware requirements.

Features

  • Provides 16 digital inputs within a compact 12 mm mechanical footprint.
  • Utilizes negative switching (sink) logic configuration.
  • Employs 1-wire connection technology with direct plug-in connection for solid conductors.
  • Tool-free termination for solid conductors; simple spring actuation by screwdriver for stranded wires and ferrules.
  • Integrated hardware input filter (typ. 3.0 ms) to suppress line bounce and noise.
  • Complete 500 V galvanic isolation between the internal K-bus and the field potential.
  • Address-free configuration for immediate plug-and-play installation within the Bus Coupler process image.

Applications

  • Space-constrained decentralized control systems and distribution cabinets.
  • Automated assembly systems, packaging machinery, and material handling lines.
  • Sensor signal concentration in industrial process automation.
  • General manufacturing and PLC I/O expansion environments.

Technical Specifications

Manufacturer BECKHOFF
Part Number/Model KL1889
Connection Technology 1-wire
Specification Negative switching (sink)
Number of Inputs 16
Nominal Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage 18 to 30 V
"1" Signal Voltage 0 to 7 V
Input Filter typ. 3.0 ms
Input Current typ. 3 mA
Current Consumption (K-bus) typ. 20 mA
Current Consumption (Power Contacts) typ. 4 mA + load
Electrical Isolation 500 V (K-bus to field potential)
Bit Width in Process Image 16 inputs
Conductor Connection (Solid) Direct plug-in technique (0.08 to 1.5 mm²)
Conductor Connection (Stranded) Spring actuation by screwdriver (0.25 to 1.5 mm²)
Conductor Connection (Ferrule) Spring actuation by screwdriver (0.14 to 0.75 mm²)
Weight approx. 55 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP20

Connections and Interfaces

Connection Type Conductor Type Cross-section Range
Direct Plug-In Solid Wire 0.08 to 1.5 mm²
Screwdriver Spring Actuation Stranded Wire 0.25 to 1.5 mm²
Screwdriver Spring Actuation Ferrule 0.14 to 0.75 mm²

Installation Guidelines

  • Ensure the system power supply is completely disconnected before mounting or removing the terminal.
  • Mount the module onto a standard 35 mm DIN rail (EN 60715) with vertical or horizontal mounting orientation as required.
  • Ensure the side locking mechanism of the bus terminal engages correctly with adjacent terminals to secure reliable K-bus and power contact transmission.
  • Utilize appropriate shielding and grounding procedures for sensor lines to prevent electromagnetic interference from distorting input signals.

Compliance and Certifications

  • CE
  • UL
  • Ex
  • GL
Loading product navigation…

What is the signal logic used by the BECKHOFF KL1889?

The KL1889 uses negative switching (sink) logic with 16 digital inputs.

What type of connection technology does the KL1889 support?

The module utilizes 1-wire connection technology, allowing direct conductor routing for digital signals with minimal wiring overhead.

Does the KL1889 require software addressing during setup?

No, the KL1889 is address-free and does not require software configuration; it integrates automatically into the K-bus process image.

What are the allowed conductor types and sizes for connection?

It supports solid wire (0.08 to 1.5 mm²), stranded wire (0.25 to 1.5 mm²), and ferrules (0.14 to 0.75 mm²).

What is the IP rating of the KL1889 housing?

The KL1889 has an IP20 protection class and must be installed within an appropriate control cabinet or enclosure.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...