1 von 3

Bently Nevada 135785-01 3500/93 Display Unit, Non Backlighted

Bently Nevada 135785-01 3500/93 Display Unit, Non Backlighted

Nur noch 6 Artikel auf Lager verfügbar
  • Hersteller: Bently Nevada

  • Produkt-Nr.: 135785-01

  • Herkunftsland:Vereinigte Staaten

  • Produkttyp: Display Unit

  • Strichcode: 8537101190

  • Zahlung: T/T, Western Union

  • Gewicht: 2100g

  • Abmessungen: 412.8 mm x 203.2 mm x 31.2 mm (W x H x D)

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

The Bently Nevada 135785-01 is a non-backlighted display unit designed for providing local or remote visual indication of 3500 Machinery Protection System data residing in the rack. The 135785-01 collects system information via a high-speed internal network, including System Event Lists, Alarm Event Lists, and channel, monitor, relay module, Keyphasor module, or tachometer module data. It utilizes a reflective 640 x 200 dots FSTN dot matrix LCD display without a backlight, requiring ambient white light for visual operation. The unit interfaces with the 3500/93 Display Interface Module (DIM) over an RS422 hardware interface supporting Bently Nevada proprietary protocol and Modbus protocol.

Features

  • Reflective 640 x 200 dots FSTN dot matrix LCD screen displays data in graphical and text formats without backlighting.
  • Provides dedicated visual indication via Unit OK LED, Rack OK LED, Rack Alert LED, Rack Danger LED, New Alarm LED, and 8 individual channel OK, Alert, and Danger status LEDs.
  • Communicates with the Display Interface Module via RS422 hardware interface with 1 second typical channel update rate.
  • Supports Bently Nevada proprietary protocol and Modbus protocol based on AEG PI-MBUS-300 Rev. E Reference Manual.
  • Maximum power consumption of 5.6 watts.

Applications

  • Local or remote visual monitoring of 3500 Machinery Protection System parameters.
  • System Event List and Alarm Event List viewing in API 670 machinery protection systems.
  • Visual alarm and channel status indication across 3500 rack installations.

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Model Part Number 135785-01
Display Type Reflective 640 x 200 Dots FSTN Dot Matrix LCD (Non-backlighted)
Display Visibility Requires ambient white light; best under indirect sunlight; acceptable under normal office lighting
Power Consumption 5.6 watt maximum
Communication Interface RS422 Interface
Communication Protocols Bently Nevada proprietary protocol; Modbus protocol (AEG PI-MBUS-300 Rev. E based)
Channel Update Rate 1 second, typical
Operating Temperature -20 degC to 65 degC (-4 degF to 149 degF)
Storage Temperature -30 degC to 80 degC (-22 degF to 176 degF)
Operating Humidity 95%, noncondensing
Dimensions (Height x Width x Depth) 203.2 mm x 412.8 mm x 31.2 mm (8.00 in x 16.25 in x 1.23 in)
Weight 2.1 kg (4.6 lb.)

Installation Guidelines

  • Ensure adequate ambient white light or indirect sunlight is present in the mounting area for acceptable LCD visibility.
  • Connect the unit to the Display Interface Module using the designated cable connection (PVC or Teflon options).
  • When implementing cable distances greater than 100 feet (up to 4000 feet), utilize an External Power Supply and Cable Adapter.

Compliance and Certifications

Standard / Approval Details
EMC Directives EN50081-2 (EN 55011 Class A), EN50082-2 (EN 61000-4-2, ENV 50140, ENV 50141, EN 61000-4-4, EN 61000-4-5, EN 61000-4-8, EN 61000-4-11, ENV 50204)
Low Voltage Directives EN 61010-1 Safety Requirements
Hazardous Area Approvals CSA/NRTL/C: Class I, Division 2, Groups A through D
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 135785-01 3500/93 Display Unit, Non Backlighted

What display screen technology is used on the unit?

The device features a non-backlighted reflective 640 x 200 dots FSTN dot matrix LCD requiring ambient white light for visibility.

What is the maximum power consumption of this module?

The non-backlighted display unit operates with a maximum power consumption of 5.6 watts.

Which communication protocols are supported for system data transfer?

The device uses an RS422 hardware interface supporting Bently Nevada proprietary protocol and Modbus protocol.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage per DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir beliefern über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden von Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails sehen Sie bitte unsere offiziellen Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Color pattern
Grauweiß
Country of origin
Vereinigte Staaten

Kürzlich angesehene Produkte

Technisches Wissen

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Modernisierung der Bailey INFI 90 Symphony-HMIs unter OpenVMS Alpha

Ein praxisnaher Leitfaden zum Ersetzen veralteter Bailey-Symphony-Bedienerstationen mit OpenVMS Alpha. Er vergleicht die Alpha-Emulation, die Migration von OpenVMS auf x86, die Umstellung auf OPC und...

Warum Wartungsdaten für die industrielle Zuverlässigkeit unerlässlich sind

Wartungsdaten verknüpfen Arbeitsaufträge, Sensorsignale, Anlagenhistorie, Kosten und das Wissen der Techniker. Richtig eingesetzt verbessern sie die Planung, Zuverlässigkeit, vorausschauende Wartung,...

Elektrische Aktuatoren als Ersatz für Fluidtechniksysteme: Ein praxisnaher Leitfaden zur industriellen Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Aktuatoren, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung verändern, indem sie herkömmliche pneumatische und hydraulische...

Mathematische Operationen mit OpenPLC für Anwendungen in der industriellen Automatisierung

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...