1 von 3

Bently Nevada 140482-01 3500/42M Prox/Velom I/O Module with External Terminations

Bently Nevada 140482-01 3500/42M Prox/Velom I/O Module with External Terminations

Nur noch 4 Artikel auf Lager verfügbar
  • Hersteller: Bently Nevada

  • Produkt-Nr.: 140482-01

  • Herkunftsland:Vereinigte Staaten

  • Produkttyp: I/O Modules

  • Strichcode: 8537101190

  • Zahlung: T/T, Western Union

  • Gewicht: 200g

  • Abmessungen: 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

The Bently Nevada 140482-01 is a Prox/Velom I/O module with external terminations designed for signal interfacing between transducers and the 3500/42M Proximitor Seismic Monitor or 3500/72M Recip Rod Position Monitor. The module routes input signals from Proximitor, accelerometer, Velomitor, or HTVS transducers located in the field through the rear slot of a 3500 system rack directly into the main monitor board. It conditions incoming signals and delivers power supply outputs while maintaining signal integrity for 4-channel vibration and position monitoring operations.

Features

  • Accepts inputs from Proximitor, accelerometer, Velomitor, or HTVS transducers
  • External termination interface design for off-rack field wiring connection
  • Supports multi-channel signal routing to the 3500/42M and 3500/72M monitor main boards
  • Occupies 1 full-height rear slot in the 3500 system rack

Applications

  • Machinery protection and condition monitoring
  • Hydro-turbines, gas turbines, and steam turbines
  • Reciprocating compressor rod position and drop monitoring
  • Industrial pumps, fans, and motor assemblies

Ordering Information

Part / Option Description
140482-01 Prox/Velom I/O Module with External Terminations
125808-08 Proximitor / Velomitor External Termination Block (Euro Style Connectors)
128015-08 Proximitor / Velomitor External Termination Block (Terminal Strip Connectors)
129525-AAAA-BB 3500 Transducer XDCR signal to External Termination Block Cable
00561941 3500/42M Prox/Velom I/O Module 10-pin connector shunt

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada (a Baker Hughes Company)
Model 140482-01
Module Type Prox/Velom I/O Module with External Terminations
Compatible Transducers Prox/Accel, Velomitor, HTVS
Supply Parameters (Prox/Accel) U = 23.9 V, I = 45.5 mA, P = 1.09 W
Supply Parameters (Velomitor) U = 23.9 V, I = 45.5 mA, P = 1.09 W
Rack Space Requirement 1 full-height rear slot
Operating Temperature -30 degC to +65 degC (-22 degF to +150 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Humidity 95%, noncondensing
Dimensions (H x W x D) 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Weight 0.20 kg (0.44 lb)

Installation Guidelines

  • Install the module into 1 full-height rear slot corresponding to the associated front monitor module in the 3500 rack.
  • Connect the external termination block to the rear module using the designated 129525 external termination cable.
  • Ensure proper field wiring connection on the external termination block with supported transducer types.
  • Do not attempt to use external termination blocks with internal termination I/O modules.

Compliance and Certifications

Category Standard / Certification
EMC EN 61000-6-2, EN 61000-6-4 (Directive 2014/30/EU)
Electrical Safety EN 61010-1 (Directive 2014/35/EU)
RoHS Directive 2011/65/EU; China RoHS EFUP 15 years (SJ/T 11364-2024)
Hazardous Area (cNRTLus) Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D (T4 @ Ta= -20 degC to +65 degC)
Hazardous Area (ATEX/IECEx) II 3 G Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 @ Ta= -20 degC to +65 degC)
Maritime ABS-Marine and Offshore Applications; DNV GL Rules for Classification
Loading product navigation…

Where is the I/O module installed in the 3500 system rack?

The module installs in 1 full-height rear slot directly behind the matching monitor module.

Which transducer types can connect to this external termination module?

The device accepts Proximitor, accelerometer, Velomitor, and HTVS transducer inputs.

What cable is used to connect the module to the external termination block?

The module connects via the 129525 transducer signal to external termination block cable.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage per DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir beliefern über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden von Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails sehen Sie bitte unsere offiziellen Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Color pattern
Silber
Country of origin
Vereinigte Staaten

Kürzlich angesehene Produkte

Technisches Wissen

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Modernisierung der Bailey INFI 90 Symphony-HMIs unter OpenVMS Alpha

Ein praxisnaher Leitfaden zum Ersetzen veralteter Bailey-Symphony-Bedienerstationen mit OpenVMS Alpha. Er vergleicht die Alpha-Emulation, die Migration von OpenVMS auf x86, die Umstellung auf OPC und...

Warum Wartungsdaten für die industrielle Zuverlässigkeit unerlässlich sind

Wartungsdaten verknüpfen Arbeitsaufträge, Sensorsignale, Anlagenhistorie, Kosten und das Wissen der Techniker. Richtig eingesetzt verbessern sie die Planung, Zuverlässigkeit, vorausschauende Wartung,...

Elektrische Aktuatoren als Ersatz für Fluidtechniksysteme: Ein praxisnaher Leitfaden zur industriellen Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Aktuatoren, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung verändern, indem sie herkömmliche pneumatische und hydraulische...

Mathematische Operationen mit OpenPLC für Anwendungen in der industriellen Automatisierung

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...