1 von 1

Bently Nevada 3500/15-04-04-CN 3500 Series Power Supply Module

Bently Nevada 3500/15-04-04-CN 3500 Series Power Supply Module

Nur noch 4 Artikel auf Lager verfügbar
  • Hersteller: Bently Nevada

  • Produkt-Nr.: 3500/15-04-04-CN

  • Herkunftsland:Vereinigte Staaten

  • Produkttyp: Machinery Protection System Power Supplies

  • Zahlung: T/T, Western Union

  • Gewicht: 320g

  • Abmessungen: 32.0 cm x 15.0 cm x 21.0 cm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

To ensure continuous, uninterrupted monitoring within the critical 3500 Machinery Protection System, the Bently Nevada 3500/15-04-04-CN provides redundant, highly stable power distribution to all rack-installed modules. This half-height module is configured with dual low-voltage DC inputs to accept power from independent sources, minimizing the risk of a single-point failure in high-availability industrial monitoring setups. By utilizing high-frequency filtering and precise voltage regulation, it safeguards sensitive internal measurement cards from external electrical transients and voltage drops common in heavy industrial facilities.

Key Features

  • Dual Low-Voltage DC Input: Configured with option code 04 for both top and bottom slots, accepting input voltages from 20 to 30 Vdc.
  • Redundancy Support: Allows installation of two power supplies within the same 3500 rack to ensure zero-downtime operations if a single supply fails.
  • Internal Diagnostics: Continuously monitors output levels and communicates status backplane health directly to the Rack Interface Module (RIM).
  • Active Surge Protection: Built-in transient voltage surge suppression (TVSS) prevents power grid anomalies from damaging down-stream components.
  • CN Regional Approvals: Certified for specific regional compliance, facilitating straightforward commissioning in governed industrial zones.

Applications

  • Power Generation: Ensures high-reliability machinery protection for steam, gas, and hydro turbines.
  • Oil and Gas Processing: Delivers critical protection system power in petrochemical facilities, offshore platforms, and refinery control rooms.
  • Heavy Manufacturing: Protects large-scale air compressors, high-power cooling pumps, and industrial fans.
  • Water Treatment: Powers monitor systems in municipal pumping stations and high-volume wastewater plants.

Technical Specifications

Parameter Value / Specification
Manufacturer Bently Nevada (Baker Hughes)
Part Number 3500/15-04-04-CN
Series 3500 Machinery Protection System
Module Type Half-Height Power Supply Module
Power Supply Type (Top Slot) 04 = Low Voltage DC (20 to 30 Vdc)
Power Supply Type (Bottom Slot) 04 = Low Voltage DC (20 to 30 Vdc)
Rated Input Voltage Range 20 to 30 Vdc
Agency Approval Option CN = Country-specific regional approvals
Country of Origin United States (USA)
Net Module Weight 1.39 kg (3.06 lbs)
Shipping Weight (Calculated) 3.00 kg (6.61 lbs)
Package Dimensions (Calculated) 32.0 cm x 15.0 cm x 21.0 cm

Empirical Engineering Insights

Alternative Models & Compatibility

The 3500/15-04-04-CN is designed specifically for integration with the standard 3500 series chassis. It cannot be mixed with high-voltage AC modules on the same input terminal configuration. Ensure your backplane jumpers are verified for DC distribution when performing migrations from older AC-based legacy 3500/15 systems.

Application Pitfalls & Engineering Notes

In enclosed field panels where ambient operating temperatures exceed 50 degC, running redundant power supplies generates localized hot spots. We advise maintaining a minimum 1U ventilation clearance directly above the rack or installing internal chassis fan assemblies to prevent thermal overload and minimize wear on the supply’s electrolytic smoothing capacitors.

Commissioning & Wiring Tips

Always use high-purity, multi-strand 14 AWG copper wire to handle the high current demands at the lower end of the 20 Vdc threshold. Prior to energizing, ensure the instrument earth and rack chassis grounds are securely bonded at a single point to prevent ground loops that could introduce high-frequency noise to adjacent machinery vibration cards.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Ensure all primary low-voltage power feed breakers are fully de-energized, locked out, and tagged out (LOTO) prior to terminal block connection or removal. Failure to secure source power can result in terminal arcing, system backplane damage, and personnel injury.

1

Slide the half-height module carefully into the designated left-hand power slots of the 3500 rack chassis until it seats firmly into the backplane connectors.

2

Hand-tighten the integrated retaining thumb screws on the front panel to secure the module mechanically against vibration.

3

Connect the external 24 Vdc feed conductors to the appropriate terminals on the input terminal block at the rear of the rack, taking strict care to maintain correct polarity (+/-).

4

Energize the feed circuit breaker and confirm that the front panel OK LED is illuminated green, indicating correct voltage output.

Loading product navigation…

What does the 3500/15-04-04-CN input voltage options signify?

The '04-04' options designate that both the top and bottom slot power configurations are set for low-voltage DC input, accepting a range from 20 to 30 Vdc.

Can this power supply handle fully redundant input feeds?

Yes. When two 3500/15 power supplies are installed in the same 3500 rack, the lower supply can power the rack if the upper supply fails, or vice versa, supporting dual independent sources.

Does the CN suffix affect physical installation or compatibility?

No. The CN suffix indicates country-specific agency approval options (such as regional industrial certifications) and does not modify the dimensions, inputs, or operational backplane interface.

What is the recommended wire sizing for the low-voltage DC connections?

It is recommended to use at least 14 AWG copper wire to avoid excessive voltage drops between the source and the 3500 rack terminals under high-load conditions.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Vereinigte Staaten

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...