1 از 1

BECKHOFF IL2302-B518 Fieldbus Box CANopen Coupler Box

BECKHOFF IL2302-B518 Fieldbus Box CANopen Coupler Box

فقط 10 قلم کالا در انبار باقی مانده است
  • تولیدکننده: BECKHOFF

  • شماره محصول: IL2302-B518

  • کشور سازنده:آلمان

  • نوع محصول: Coupler Boxes

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 500g

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Designed to interface decentralized I/O signals directly in the field, the IL2302-B518 serves as a robust CANopen coupler box within the Beckhoff Fieldbus Box system. This module provides direct connection of IP-Link extension modules to a CANopen network, offering a highly efficient solution for distributing digital and analog signals without requiring a protective control cabinet.

The IL2302-B518 coordinates the transfer of decentralized process data from up to 120 extension modules to the higher-level controller. By integrating the fieldbus interface, power supply connections, and IP-Link communication into a single compact housing, this module minimizes installation complexity and space requirements in demanding industrial environments.

Features

  • Supports connection of up to 120 IP-Link extension modules.
  • Handles a maximum of 128 bytes of input data and 128 bytes of output data.
  • Integrated T-connector for seamless CANopen network routing.
  • Automatic detection of data transfer rates from 10 kbaud up to 1 Mbaud.
  • Comprehensive CANopen feature support including Node Guarding, Life Guarding, and Emergency Objects.
  • Configurable via the KS2000 software tool or through standard Service Data Objects (SDOs).

Applications

  • Heavy industrial machinery and manufacturing lines.
  • Material handling and conveyor systems.
  • Packaging and food processing equipment.
  • Decentralized control installations in washdown or high-dust zones.

Technical Specifications

ManufacturerPart Number / ModelProduct TypeProtocolNumber of Extension ModulesDigital Signal CapacityAnalog Signal CapacityNumber of PDOsData Transfer RatesPower Supply VoltageBox Supply CurrentElectrical IsolationProtection RatingOperating TemperatureStorage TemperatureVibration/Shock ResistanceEMC Immunity/Emission
BECKHOFF
IL2302-B518
CANopen Coupler Box
CANopen
Max. 120 (max. 128 byte input / 128 byte output)
Max. 960 inputs and 960 outputs
Max. 60 inputs and 60 outputs
16 send and 16 receive process data objects
10 kbaud to 1 Mbaud (automatic detection)
24 V DC (-15% / +20%)
45 mA + sensor current consumption (max. 0.5 A)
500 V (Control voltage / fieldbus)
IP65, IP66, IP67 (conforms to EN 60529)
0 to +55 degC
-25 to +85 degC
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Bus Interface (Input)Bus Interface (Output)Power FeedPower Downstream
Interface Type Connector Description Function
1 x M12 plug, 5-pin CANopen incoming bus connection
1 x M12 socket, 5-pin CANopen outgoing bus connection (integrated T-connector)
1 x M8 male socket, 4-pin Control voltage and sensor power feed
1 x M8 female socket, 4-pin Power distribution to downstream modules

Installation Guidelines

  • Ensure the unit is securely mounted to a flat surface using the integrated mounting holes.
  • To maintain the IP67 protection rating, all unused M8 and M12 connection ports must be sealed with appropriate protective caps.
  • Verify that the control voltage is stable at 24 V DC before powering the network.
  • Keep bus cables isolated from high-voltage AC cables to minimize electromagnetic interference.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What is the maximum number of extension modules the Beckhoff IL2302-B518 can support?

The IL2302-B518 coupler box can support up to 120 extension modules with a maximum of 128 bytes of input data and 128 bytes of output data.

Does this coupler box require a separate T-connector for the CANopen network?

No, the IL2302-B518 features an integrated T-connector with one M12 plug and one M12 socket, allowing direct network daisy-chaining.

What is the environmental protection rating of the IL2302-B518?

The module is rated IP65, IP66, and IP67, making it suitable for direct installation in harsh field environments without a control cabinet.

Does the module support automatic baud rate selection?

Yes, it features automatic detection of data transfer rates ranging from 10 kbaud up to 1 Mbaud.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
آلمان

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...