1 از 1

Beckhoff IP2401-B520 Fieldbus Box DeviceNet Module

Beckhoff IP2401-B520 Fieldbus Box DeviceNet Module

فقط 10 قلم کالا در انبار باقی مانده است
  • تولیدکننده: BECKHOFF

  • شماره محصول: IP2401-B520

  • کشور سازنده:آلمان

  • نوع محصول: Fieldbus Box Modules

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 500g

  • ابعاد: 2 x 2 x 0.25 mm

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

For processing decentralized I/O signals directly on machinery, the Beckhoff IP2401-B520 Fieldbus Box serves as a ruggedized DeviceNet interface module. This IP67-rated unit bypasses the need for protective control cabinets by mounting directly within harsh processing environments. It features automated transmission rate configuration and direct integration with DeviceNet networks via industrial M12 cabling. The device manages internal logic execution and signal routing, enabling efficient, low-latency control architecture in distributed automation systems.

Features

  • Automatic Baud Rate Detection: Automatically synchronizes with the network master at speeds up to 500 kbaud.
  • Direct Machine Mounting: High protection rating (IP65/66/67) allows installation outside of standard control enclosures.
  • Standardized M12 Fieldbus Interface: Features a 5-pin, A-coded M12 connection for reliable signal delivery.
  • Flexible Configuration: Parameterization is fully supported via KS2000 configuration software or directly through controller-level explicit messaging.
  • Optimized Power Routing: Utilizes standard M8 connections with a feed-through downstream design to minimize cabling runs across machinery.

Applications

  • Decentralized conveyor systems and automated material handling lines.
  • Food processing and packaging machinery requiring high-pressure washdown resilience.
  • Automotive assembly lines utilizing distributed DeviceNet fieldbus topologies.
  • Machine tool control systems with localized pneumatic or digital sensor clusters.

Technical Specifications

Manufacturer Beckhoff
Model Identifier IP2401-B520
Fieldbus Interface 1 x M12 plug, 5-pin
Data Transfer Rates Automatic detection up to 500 kbaud
Transmission Medium Shielded copper cable, with power supply, typ. 2 x 2 x 0.25 mm²
Control Supply Voltage 24 V DC (-15 % / +20 %)
Power Supply Connections Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin
Box Current Consumption 45 mA + sensor current load (maximum 0.5 A)
Electrical Isolation 500 V (Control voltage to fieldbus logic)
Station Distances Up to 500 m (125 kbaud) / 250 m (250 kbaud) / 100 m (500 kbaud)
Communication Types Bit strobe, polling, cyclic, change of state (COS)
IP Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Standards & Standards Compliance EN 60068-2-6 (Vibration) / EN 60068-2-27 (Shock)
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals CE, UL
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Connection Type Connector Specification Assignment & Purpose
DeviceNet Bus M12 plug, 5-pin, A-coded Standard DeviceNet transceiver interface (Shield, V+, V-, CAN_H, CAN_L)
Power Input (Feed) M8 male, 4-pin 24 V DC control voltage input and system power supply
Power Output (Downstream) M8 female, 4-pin Daisy-chain connection to downstream Fieldbus Box modules

Empirical Engineering Insights

Alternative Models & Compatibility

When replacing legacy Beckhoff IP-series boxes, verify the exact DeviceNet master configuration files (.EDS). The IP2401-B520 has built-in baud rate auto-negotiation, but static master settings may require hardcoded speed adjustments via your controller software if automatic detection fails to lock during initial handshake cycles.

Application Pitfalls & Engineering Notes

While the module features IP67 ingress protection, ensure that all unused M12 and M8 ports are sealed with industrial-grade protective caps. Condensation buildup inside open sockets will compromise the internal 500 V electrical isolation between control logic and the physical network transceiver layer, leading to intermittent fieldbus fault codes.

Commissioning & Wiring Tips

Always wire a dedicated 121-ohm terminating resistor across the CAN_H and CAN_L pins at both physical ends of your DeviceNet segment. If run over long distances (exceeding 100 meters), do not run the bus cables adjacent to high-voltage variable frequency drive (VFD) output cables to avoid noise coupling, despite the EN 61000-6-2 industrial immunity certification.

Installation Guidelines

CRITICAL WARNING

Before beginning installation, mount replacement, or wiring reconfiguration, verify all 24 V DC control and external load voltages feeding the module are completely de-energized. Failure to isolate power prior to plugging or unplugging M8 and M12 industrial connections can result in pin arcing, contact oxidation, or transceiver degradation.

1

Mount the Fieldbus Box to a flat, vibration-damped surface using M4 screws. Ensure the mounting position permits visual inspection of status LEDs.

2

Connect the DeviceNet communication cable to the 5-pin M12 connector. Tighten the connector hand-tight to ensure an IP67 seal; do not use pliers.

3

Route the 24 V DC control power source into the M8 input plug. If routing power to multiple boxes in a chain, link the M8 output receptacle to the next module's input.

4

Verify DeviceNet node addressing through your configuration software and commission the network to test automatic baud rate detection.

Loading product navigation…

What is the maximum transmission distance for this DeviceNet box?

The maximum network distance depends on the transmission speed: up to 500 meters at 125 kbaud, 250 meters at 250 kbaud, and 100 meters at 500 kbaud.

How is the node address configured on this module?

The node address and baud rate can be configured using the KS2000 software interface or directly via the system controller using explicit messaging.

What cable specifications are recommended for the fieldbus connection?

A shielded copper cable with integral power supply is required, typically structured as 2 x 2 x 0.25 square millimeters.

Does the control voltage have electrical isolation from the fieldbus network?

Yes, the module provides 500 V electrical isolation between the 24 V DC control voltage and the fieldbus communication circuitry.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
آلمان

محصولات مشاهده‌شده اخیر

دانش فنی

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...