Beckhoff IP5009-B318 Fieldbus Box SSI Sensor Interface

Beckhoff IP5009-B318 Fieldbus Box SSI Sensor Interface

فقط 10 قلم کالا در انبار باقی مانده است
  • تولیدکننده: BECKHOFF

  • شماره محصول: IP5009-B318

  • کشور سازنده:آلمان

  • نوع محصول: Fieldbus Box Modules

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 500g

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Decentralized acquisition of high-frequency sensor data is directly enabled by the Beckhoff IP5009-B318, an IP67-rated PROFIBUS DP Fieldbus Box designed for harsh operating environments. This module interfaces absolute encoders or displacement sensors utilizing the SSI (Synchronous Serial Interface) protocol, transferring data directly to the higher-level master controller via PROFIBUS DP. With integrated B-coded M12 connections acting as a built-in T-connector, the module allows for direct bus line looping without requiring external active junctions. Configuration and parameters can be easily adjusted using the KS2000 software tool or directly via controller-driven DP-V1 acyclic slot communication.

Features

  • PROFIBUS DP Compatibility: Complete support for baud rates up to 12 Mbaud with integrated automatic speed detection.
  • Rugged Enclosure Design: Full IP65, IP66, and IP67 protection ratings, eliminating the need for protective control cabinets in the field.
  • Integrated Loop-Through: M12 male and female B-coded interfaces enable simple daisy-chaining of the fieldbus line.
  • Flexible Configuration: Supports DP-V1 communication extensions for dynamic, runtime parameter adjustments.
  • Reliable Power Distribution: Standardized M8 connectors for control voltage and downstream load distribution.

Applications

  • Decentralized SSI absolute encoder feedback in packaging and material handling systems.
  • High-accuracy position sensing on outdoor linear axes and heavy machinery.
  • Automotive assembly lines requiring direct, field-mounted sensor integration.
  • Wind turbine pitch control systems and waste-water treatment plants.

Technical Specifications

Parameter Value
Manufacturer Beckhoff
Model Number IP5009-B318
Fieldbus Protocol PROFIBUS DP (with DP-V1 support)
Data Transfer Rates Up to 12 Mbaud (automatic detection)
Fieldbus Interface 1 x M12 socket (5-pin), 1 x M12 plug (5-pin), B-coded
Control Voltage Supply 24 V DC (-15% / +20%)
Current Consumption (Box Supply) 85 mA + sensor load (max. 0.5 A)
Power Feed / Downstream 1 x M8 male socket (4-pin) / 1 x M8 female socket (4-pin)
Isolation (Control / Fieldbus) None (electrical isolation is determined by sensor configuration)
Cycle Time Approx. 0.5 ms (for typical network of 10 boxes with 32-bit I/O each)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
Approvals CE, UL
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Interface Connection Pin Number Signal Assignment
PROFIBUS DP M12 (B-coded) Pin 1 VP (+5 V DC for active termination)
Pin 2 RxD/TxD-N (A-line, Green)
Pin 3 DGND (Data Ground)
Pin 4 RxD/TxD-P (B-line, Red)
Pin 5 Shield
Power M8 (Feed Connection) Pin 1 +24 V DC control voltage (Us)
Pin 2 +24 V DC load voltage (Up)
Pin 3 GND (Us)
Pin 4 GND (Up)

Alternative Models & Compatibility

The IP5009-B318 replaces several legacy non-coupled configurations by bringing SSI decoding down to the machine level. Ensure your GSD file is updated to include the exact module parameters to prevent cyclic data exchange errors with older master systems. For setups utilizing the EtherCAT network topology rather than PROFIBUS, the EP5001-0002 serves as the native EtherCAT fieldbus equivalent.

Application Pitfalls & Engineering Notes

When daisy-chaining multiple boxes via the M8 power distribution interfaces, calculate the total voltage drop. The cumulative control current (Us) should not exceed 4 A across a single segment to prevent high thermal stress on the internal bus rails. Since control voltage and fieldbus communications do not share electrical isolation inside the module, run all system fieldbus lines in separated, shielded trays to prevent EMI-induced communication dropouts.

Commissioning & Wiring Tips

For optimal performance, use a terminating resistor if the IP5009-B318 acts as the physical last node in the PROFIBUS segment. Standard active termination can be accomplished using an M12 B-coded terminator connected to the downstream socket interface. Ensure the SSI sensor cable is shielded and connected directly to the designated housing shield collar to maintain signal integrity during dynamic motor acceleration cycles.

Installation Guidelines

CRITICAL SAFETY WARNING

Isolate all electrical power sources before initiating installation, removal, or wiring processes. Verify that both control and load voltages (Us and Up) are fully de-energized. Failure to strictly follow these safety steps can cause immediate physical danger or catastrophic failures to connected high-precision SSI sensors.

1

Mount the Fieldbus Box on a flat, vibration-free surface using two M4 mounting screws.

2

Securely torque the M12 B-coded PROFIBUS cable connectors to prevent moisture and dust ingress.

3

Wire the M8 power supply connection, ensuring polarity matches for both control (Us) and load (Up) segments.

4

Verify connection status and baud rate sync via the diagnostic LEDs prior to running system processes.

Loading product navigation…

What configuration tools are needed to set up the IP5009-B318?

Configuration can be achieved directly via the Beckhoff KS2000 software tool, or acyclically from your primary controller using DP-V1 PROFIBUS parameters.

Does this Fieldbus Box include integrated line termination?

No, it features a loop-through M12 B-coded connection. If placed at the end of the PROFIBUS line, an external M12 terminating resistor plug must be installed.

What is the maximum current limit for connected sensors?

The total sensor supply current is limited to a maximum of 0.5 A, in addition to the base box supply current of 85 mA.

Are the control voltage and fieldbus lines isolated from one another?

No. The IP5009-B318 does not feature electrical isolation between the control voltage input and the fieldbus communication circuit. Adequate field shielding is highly recommended.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
آلمان

محصولات مشاهده‌شده اخیر

دانش فنی

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...