1 از 1

Honeywell LCNP4E 51405098-100 LCN PCI Express Module

Honeywell LCNP4E 51405098-100 LCN PCI Express Module

فقط 4 قلم کالا در انبار باقی مانده است
  • تولیدکننده: Honeywell

  • شماره محصول: LCNP4E / 51405098-100

  • کشور سازنده:ایالات متحده آمریکا

  • نوع محصول: LCN Interface Cards

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 2000g

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

The Honeywell 51405098-100 (commonly designated as the LCNP4E) is a specialized Local Control Network interface board engineered for integration within legacy Honeywell TDC 3000 and Honeywell Experion PKS distributed control systems (DCS). Functioning as a high-performance coprocessor card, this module installs into a standard PCI Express (PCIe) slot of a host workstation or server. It provides the essential physical and protocol link required for the host operating system to communicate deterministically with the Honeywell coaxial Local Control Network (LCN).

By offloading low-level network protocol stacks and critical transmission timing from the host computer's primary CPU, the LCNP4E Card Module ensures highly reliable, real-time data exchange for operator interfaces, alarm management, historical data archiving, and engineering configuration tools. Its hardware design is specifically optimized to maintain stable throughput under high-density industrial communication demands.

Features

  • PCI Express Interface: Utilizes standard PCIe bus connectivity for broad compatibility with modern industrial PCs and server motherboards.
  • On-Board Coprocessor: Dedicates localized hardware resources to handle LCN communication protocols, minimizing host CPU overhead.
  • Dual-Redundant Ports: Equipped with dual coaxial connections to seamlessly interface with redundant (A and B) Local Control Network physical topologies.
  • Diagnostic Indicators: Features onboard LED status lights for rapid troubleshooting of link activity, board health, and communication faults.
  • System Compatibility: Engineered for direct integration with Honeywell Experion and classic TDC 3000 system architectures.

Applications

  • Honeywell TDC 3000 Operator Station upgrades.
  • Experion PKS LCN connection node interfaces.
  • Process control network legacy-to-modern PC migrations.
  • Power generation, chemical processing, and oil refining DCS environments.

Technical Specifications

Manufacturer Honeywell
Part Number / Model LCNP4E / 51405098-100
Interface Slot Type PCI Express (PCIe)
Network Compatibility Honeywell Local Control Network (LCN)
Physical Connector Type Dual Coaxial BNC Connections
Shipping Weight 2.0 kg

Connections and Interfaces

Connector / Indicator Function Description
LCN Port A Connection point for the primary LCN coaxial network segment.
LCN Port B Connection point for the redundant LCN coaxial network segment.
LED Status Indicators Real-time visual feedback for communication transmit/receive and hardware status.

Installation Guidelines

  • Static Protection: Use a grounded ESD wrist strap and anti-static mat when handling the card to prevent damage to sensitive CMOS components.
  • Power Sequencing: Always shut down the host industrial PC and disconnect the main AC power supply before inserting or removing the module.
  • Slot Alignment: Align the module card-edge carefully with the targeted PCIe slot and apply even downward pressure until fully seated. Secure the mounting bracket screw to the chassis frame.
  • Cable Integrity: Use properly specified coaxial cables and BNC terminators to connect to the LCN network to avoid signal reflection and communication packet losses.
Loading product navigation…

What is the function of the Honeywell LCNP4E card module?

The LCNP4E (51405098-100) is a PCI Express co-processor card that interfaces a standard host PC or workstation with the legacy Honeywell Local Control Network (LCN) in TDC 3000 and Experion systems.

Does the 51405098-100 module support redundant network cables?

Yes, it is equipped with dual coaxial BNC connectors to interface with redundant LCN cable segments (A and B) for high availability.

Which system environments are compatible with this card?

It is designed for use in PC-based systems connected to Honeywell TDC 3000 systems and Experion PKS DCS environments that require physical LCN access.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ایالات متحده آمریکا

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...