Mitsubishi Electric FR-A740-0.4K-CHT FR-A700 Series Variable Frequency Drive

Mitsubishi Electric FR-A740-0.4K-CHT FR-A700 Series Variable Frequency Drive

فقط 10 قلم کالا در انبار باقی مانده است
  • تولیدکننده: Mitsubishi Electric

  • شماره محصول: FR-A740-0.4K-CHT

  • کشور سازنده:ایالات متحده آمریکا

  • نوع محصول: Variable Frequency Drives

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 5500g

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Engineered to provide high-performance speed and torque regulation for three-phase induction motors, the Mitsubishi Electric FR-A740-0.4K-CHT variable frequency drive delivers precise dynamic response in low-power industrial environments. This 0.4 kW inverter belongs to the robust FR-A700 Series, incorporating advanced sensorless vector control technology and localized power optimization. The "CHT" suffix indicates optimized firmware calibration and localized system parameters designed for standard regional grids, facilitating trouble-free integration into modern machinery setups.

Features

  • Advanced Real Sensorless Vector Control (RSV) delivers high starting torque and precise speed control without requiring an encoder.
  • Built-in miniature PLC functionality allows execution of basic localized control logic, reducing overhead on master controllers.
  • Dual overload capacity ratings (LD and ND) allow cost-effective matching to specific system torque profiles.
  • Integrated long-life components including cooling fans and capacitors rated for extended deployment lifespans.
  • Flexible networking compatibility through dedicated plug-in option cards for CC-Link, Profibus-DP, and DeviceNet.

Applications

  • Precision materials handling systems and localized belt conveyors requiring smooth starting torque.
  • Industrial ventilation systems, blowers, and low-horsepower centrifugal pump setups.
  • Machine tool positioning axes, automated packaging equipment, and packaging line indexers.
  • Zonal chemical dosing pumps and dynamic automated mixing apparatuses.

Technical Specifications

Manufacturer Mitsubishi Electric
Model Number FR-A740-0.4K-CHT
Series FR-A700 Series
Input Voltage Class Three-phase 400 V Class (380 to 480 V AC, 50/60 Hz)
Applicable Motor Capacity 0.4 kW (approx. 0.5 HP)
Output Frequency Range 0.2 to 400 Hz
Control Algorithms V/F Control, Real Sensorless Vector Control, Closed-loop Vector Control (with option card)
Enclosure Class IP20 (Open Type)
Operating Temperature -10 to +50 degC (non-freezing)
Shipping Weight (Calculated) 5.5 kg (12.13 lbs)
Country of Origin Japan / China (Regional OEM Facility)

Connections and Interfaces

Terminal Block Label Function Assignment
R/L1, S/L2, T/L3 Three-phase main AC power input (380-480V)
U, V, W Three-phase variable AC output to the motor terminals
P/+, PR Dedicated connections for dynamic external braking resistor
STF, STR Forward and Reverse digital start signal lines
SD Common terminal ground for external control and sink inputs
RJ45 Serial Port RS-485 Modbus RTU interface / Parameter unit physical connection

Empirical Engineering Insights

Alternative Models & Compatibility

The "CHT" variant shares identical dimensions and core power circuitry with standard FR-A740 European or North American models. However, users should note that the default system parameters (such as nominal line frequency defaults and basic digital input logic configuration) are preset to 50Hz and sink logic. If integrating this module as a direct spare part in a system running a non-CHT model, run a full parameter dump comparison via FR Configurator software to ensure matching control configurations.

Application Pitfalls & Engineering Notes

Because of the low-mass heat sink on 0.4 kW models, thermal management is heavily dependent on ambient cabinet airflows. When mounting multiple drives side-by-side, ensure a horizontal spacing of at least 10mm if operating at continuous nominal load. Do not adjust the PWM carrier frequency (Parameter 72) above 12.5 kHz in confined cabinets exceeding 40 degC without implementing a continuous forced-air cooling strategy, as the unit will preemptively trigger a thermal overload (E.THT) fault.

Commissioning & Wiring Tips

To minimize electromagnetic interference (EMI) issues characteristic of PWM frequency outputs, run a shielded four-core motor cable from terminals U, V, and W to the motor, terminating the screen on both ends using high-surface-contact EMC clamps. Never route sensitive low-voltage analog command lines (e.g., 4-20mA speed references) in parallel with main AC supply line or motor line conduits; keep a separation of at least 100mm.

Installation Guidelines

CRITICAL WARNING

Before performing any physical connection or control wiring, isolate the AC power supply. Internal capacitors retain hazardous high-voltage DC charges for several minutes after incoming power is cut. Confirm that the internal charge indicator lamp is completely unlit, and verify with a reliable multimeter that the voltage across DC terminals P/+ and N/- has dropped below 20V DC before starting terminal termination.

1

Mount the drive in a vertical orientation onto a flat, vibration-free panel using standard M4 screws, maintaining at least 50mm clear spacing above and below the unit.

2

Connect the incoming three-phase supply power to mains terminals R/L1, S/L2, and T/L3. Connect the chassis ground to the dedicated Earth connection terminal.

3

Connect the motor power cable leads to the U, V, and W terminals. Verify that no power factor correction capacitors or phase-advance devices are connected to the output path.

4

Turn on the incoming AC supply. Configure the primary parameters (Pr. 1 to Pr. 3 for basic speed limits, and Pr. 9 for motor electronic thermal relay protection) relative to your motor nameplate before initiating motor rotation.

Loading product navigation…

What does the CHT suffix represent on the FR-A740-0.4K-CHT?

The CHT suffix designates firmware customized with standard 50Hz electrical grid parameter defaults and simplified Chinese terminal identification setups, while maintaining the exact physical and electrical capabilities of standard FR-A740 units.

Can this drive run closed-loop vector control with feedback?

Yes. While standard operations are sensorless vector or V/F control, installing an optional encoder feedback card (such as the FR-A7AP) enables full closed-loop vector control on this model.

How should I mitigate high leakage currents on this 400V inverter?

Install a dedicated line noise filter, keep motor cables as short as possible, ground the drive frame securely, and if necessary, reduce the carrier frequency (Pr. 72) to minimize leakage current generation.

What is the physical frame size and cooling design of this model?

This 0.4 kW inverter is built within a highly compact IP20 physical frame size and utilizes specialized thermal convective cooling. Ensure appropriate spacing clearances inside the enclosure for proper heat dissipation.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ایالات متحده آمریکا

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...