Mitsubishi Electric FR-A840-55K-1 FR-A800 Series Variable Frequency Drive

Mitsubishi Electric FR-A840-55K-1 FR-A800 Series Variable Frequency Drive

فقط 10 قلم کالا در انبار باقی مانده است
  • تولیدکننده: Mitsubishi Electric

  • شماره محصول: FR-A840-55K-1

  • کشور سازنده:ایالات متحده آمریکا

  • نوع محصول: Variable Frequency Drives

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 44000g

  • ابعاد: 550 mm x 435 mm x 250 mm

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Optimizing heavy-duty industrial machinery performance, the Mitsubishi Electric FR-A840-55K-1 is a premium three-phase vector control variable frequency drive engineered for high-torque applications up to 55 kW. This high-performance FR-A800 series inverter features an integrated FM pulse terminal for precise monitoring and supports advanced Real Sensorless Vector Control (RSVC) to achieve exceptional speed and torque accuracy. Designed to integrate seamlessly into complex factory automation architectures, the unit provides reliable power conversion, extensive communications support, and robust energy-saving features to maximize process uptime.

Features

  • Advanced Real Sensorless Vector Control and PM sensorless vector control for unmatched motor shaft performance.
  • Built-in FM pulse train terminal providing high-resolution analog output configurations for system monitoring.
  • Integrated multi-port external communication interfaces supporting RS-485, RS-422, and RS-232 protocols.
  • Multi-rating flexibility to adapt to both Normal Duty (ND) and Light Duty (LD) operational demands.
  • Compliance with global functional safety standards including safety stop functions to minimize risk in manual intervention areas.

Applications

  • High-capacity material handling systems including cranes, hoists, and continuous conveyors.
  • Industrial fan systems, heavy-duty blowers, and municipal water supply pumping systems.
  • Continuous manufacturing machinery such as extruders, mixers, and winding systems.
  • Automated machine tool spindles and deep-well oil recovery pumping applications.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Reference FR-A840-55K-1
Series FR-A800
Applicable Motor Capacity 55 kW
Input Voltage Class Three-Phase 400 V
Output Rated Voltage Three-phase 380 to 500 V
Output Rated Current 110 A
Output Capacity 84 kVA
External Communications RS-232 / RS-422 / RS-485
Output Terminal Type FM Term (Pulse Train Output)
Approvals & Standards CE, UL, cUL, RoHS compliant
Dimensions (H x W x D) 550 mm x 435 mm x 250 mm
Product Weight 44 kg

Connections and Interfaces

Terminal Designation Functional Assignment
R/L1, S/L2, T/L3 Three-Phase AC Power Input Connection
U, V, W Three-Phase AC Output to Motor
FM Pulse Train Output Terminal for Monitoring
SD / SE Contact Input / Sensor Common Ground Terminals
RJ-45 Connector PU / RS-485 Communication Port

Alternative Models & Compatibility

The FR-A840-55K-1 serves as a direct functional replacement for legacy FR-A740-55K series drives. When replacing an older A700 series unit, parameter configurations can be transferred using Mitsubishi FR Configurator2 software. Note that although physical cabinet footprints are highly aligned, cooling fan clearances and terminal block configurations should be verified prior to structural integration.

Application Pitfalls & Engineering Notes

To maintain optimal thermal performance under continuous duty in enclosed control cabinets, do not exceed an ambient temperature of 50 Celsius without applying appropriate derating guidelines. When running this unit with high carrier frequencies to eliminate motor audible noise, ensure that the output current rating is adjusted downward according to the manufacturer derating curves to avoid thermal over-current trips (E.THT / E.OC1).

Commissioning & Wiring Tips

For installations utilizing control cable runs longer than 30 meters to the FM pulse terminal, use shielded twisted-pair (STP) cabling. Ensure that the cable shield is grounded strictly at the drive-end ground point (PE terminal) to prevent industrial high-frequency noise from inducing signal distortion or false logic transitions. Always separate control signal wiring from high-power 400 V AC inputs and motor output cabling by a minimum clearance of 30 cm.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical inputs before initiating installation or service on this equipment. High-voltage capacitors retain a lethal residual charge. Wait a minimum of 10 minutes after main power disconnection and measure the DC link voltage across terminals P/+ and N/- to verify it is below 45 V DC before touching terminal blocks or internal wiring.

1

Mount the drive vertically inside a dust-free, vibration-isolated cabinet. Ensure there is at least 100 mm of clearance above and below the drive housing for unhindered convective cooling airflow.

2

Connect the mains power input lines to terminals R/L1, S/L2, and T/L3, and connect the motor power cables to terminals U, V, and W. Tighten all terminal screws to the manufacturer-specified torque limits using a calibrated torque wrench.

3

Route control and pulse output signal lines through separate conduits to avoid electromagnetic interference. Ground the motor frame directly to the drive ground terminal, and ground the drive housing to the central protective ground bar of the facility.

Loading product navigation…

What does the FM terminal designation indicate on the FR-A840-55K-1?

The FM term suffix indicates the drive is equipped with a pulse train monitoring output. It delivers a fast, continuous pulse train signal representing variables such as motor speed, output frequency, or current.

Can I run this 55 kW drive with a standard single-phase power supply?

No, this unit is designed exclusively for three-phase 380 V to 500 V AC power grids. Attempting to power it on a single-phase supply will trigger low-voltage phase-loss faults and damage internal rectifiers.

Is the FR-A840-55K-1 backward compatible with the older FR-A740 series?

Yes, it functions as a modern replacement. Parameter conversion and migration can be handled using the FR Configurator2 application, though minor panel-mount dimensional clearances should be cross-referenced.

How long must I wait after powering off before safe wiring can begin?

You must wait at least 10 minutes to allow the high-capacity internal DC bus capacitors to discharge safely below 45 V DC. Always verify using a multi-meter at the P/+ and N/- terminals before servicing.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ایالات متحده آمریکا

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیالات: آموزش عملی

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...