1 از 1

Omron H5CX-A11-N H5CX Series Digital Multifunction Timer

Omron H5CX-A11-N H5CX Series Digital Multifunction Timer

فقط 4 قلم کالا در انبار باقی مانده است
  • تولیدکننده: Omron

  • شماره محصول: H5CX-A11-N

  • کشور سازنده:ژاپن

  • نوع محصول: Digital Timers

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 1000g

  • ابعاد: 110 x 60 x 60 mm

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Designed for precise temporal control in complex industrial automation architectures, the Omron H5CX-A11-N is an ultra-compact, 11-pin socket-mount digital multifunction timer operating on a wide 100 to 240 VAC supply voltage. This highly reliable control component integrates advanced digital timing functions with a clear, dual-color display interface, enabling seamless setup and immediate operational feedback directly on the plant floor. Engineered for longevity and performance, the H5CX-A11-N supports multiple timing modes and input configurations to easily adapt to standard electrical panels and machinery control circuits.

Key Features

  • Dual-Color Display: Highly legible PV (Present Value) display in 12 mm red characters, complemented by a 6 mm green SV (Set Value) display for instantaneous status verification.
  • Versatile Operation Modes: Supports key timing configurations including ON-delay, OFF-delay, Repeat Cycle, and Signal ON/OFF-delay to match complex automation logic.
  • Flexible Mounting: Equipped with an 11-pin round socket connector, facilitating rapid DIN-rail chassis mounting or flush panel integration.
  • Input Compatibility: Accepts both NPN (no-voltage) and PNP (voltage) external inputs for flexible sensor and controller integration.
  • Robust Memory Protection: Internal EEPROM backup retains vital user configurations and program parameters during unexpected power losses.

Applications

  • Packaging Equipment: Managing seal jaw timing, bag sealing cycles, and sorting conveyor intervals.
  • Thermal Process Units: Regulating precise heating, curing, and dwell times in industrial ovens and dryers.
  • Fluid & Pump Management: Managing alternate-pump cycling and automated backwash flush intervals in water systems.
  • Machine Tool Lubrication: Driving cyclic lubrication solenoids to protect high-speed bearing housings.

Technical Specifications

Parameter Value / Specification
Manufacturer Omron Industrial Automation
Model Code H5CX-A11-N
Operating Voltage 100 to 240 VAC, 50/60 Hz
Allowable Voltage Range 85% to 110% of rated supply voltage
Power Consumption Approx. 9.4 VA (at 240 VAC)
Control Output SPDT Contact Output: 5 A at 250 VAC / 30 VDC (resistive load)
External Input Types Signal, Reset, and Gate Inputs
Input Logic Options No-voltage input (NPN contact/transistor) / Voltage input (PNP)
Character Height Present Value (PV): 12 mm (Red); Set Value (SV): 6 mm (Green)
Case Dimensions 48 x 48 x 84.1 mm (1/16 DIN)
Ambient Operating Temp -10 to 55 degC (with no icing or condensation)
Storage Temperature -25 to 65 degC (with no icing or condensation)
Shipping Weight (Calculated) 0.30 kg
Package Dimensions (Calculated) 110 x 60 x 60 mm

Connections and Interfaces

The device utilizes a standard 11-pin round socket configuration for all electrical interfacing. Secure proper matching connections using the pinout matrix below:

Terminal Pin No. Function Assignment
Pin 1 External Input Common (0 V reference)
Pin 2 Power Supply Terminal (Neutral / L2)
Pin 3 Signal Input (Timer Start)
Pin 4 Reset Input
Pin 5 Gate Input (Timer Pause)
Pin 8 Control Output - NC (Normally Closed Contact)
Pin 9 Control Output - NO (Normally Open Contact)
Pin 10 Power Supply Terminal (Line / L1)
Pin 11 Control Output - COM (Common Contact)
Pins 6, 7 No Internal Connection (Do not wire)

Alternative Models & Compatibility

The modern H5CX-A11-N directly succeeds older non-N legacy models (e.g., H5CX-A11). This updated model features enhanced display brightness and updated firmware parameter structures. When migrating to the "N" designated unit, verify parameter configurations through the front-key system as factory default settings may vary slightly from obsolete revisions. Physical form-factor, 11-pin terminal block mapping, and mounting footprints remain strictly backward-compatible.

Application Pitfalls & Engineering Notes

Avoid routing signal inputs (Pins 1, 3, 4, 5) inside the same conduit run as heavy power lines or AC motor leads to prevent electromagnetic interference. Standard high-frequency spikes can bypass the input filter and trigger ghost starts or unexpected resets. If mounting in unventilated electrical panels alongside high-current components (like motor drives or solid-state relays), ensure local ambient temperatures do not continuously exceed the 55 degC operational threshold.

Commissioning & Wiring Tips

Before powering up the system, determine if the external control device operates on open-collector NPN or source PNP logic. The internal input selector must be correctly set via the operational keys to align with this logic. Misaligned configuration may prevent the timer from recognizing signal input pulses. When utilizing the Reset function, ensure a minimum contact pulse width of 1 ms or 20 ms is selected based on key-bounce filtration requirements in the internal parameter menu.

Installation Guidelines

CRITICAL WARNING: Verify that all AC power feeds to the panel are physically isolated, locked out, and tagged out prior to making or modifying socket wiring. Failure to do so can result in fatal electrical shock, terminal short circuits, and destruction of internal logic boards.
1
Install the compatible 11-pin socket (e.g., Omron PF113A-E) onto standard 35 mm DIN rail or panel surface cutout using verified mounting accessories.
2
Terminate power conductors (100 to 240 VAC) securely to Pin 2 and Pin 10 of the base socket, matching proper line/neutral polarization.
3
Wire sensor, reset, or logic contact inputs to Pins 1, 3, 4, and 5 using high-quality shielded signal cable with clean cable termination sleeves.
4
Insert the physical digital timer housing firmly into the socket, ensuring the alignment key in the center of the pin group seats fully without bending the connection contacts. Engage any securing clips if operating in high-vibration applications.
Loading product navigation…

What is the primary difference between the newer -N model and older H5CX-A11 models?

The H5CX-A11-N features a brighter dual-color PV/SV display, improved programming firmware options, and revised front-key layouts, while maintaining complete backward electrical and socket footprint compatibility.

Does this timer require external programming software?

No, the timer parameters and operational modes are configured directly on the device using the integrated front-panel push buttons and operational keys.

How do I switch the input control logic from NPN to PNP?

Input logic is selectable through the advanced programming parameter mode. Adjust the input mode parameter to switch internal pull-up and input trigger behaviors between NPN (no-voltage) and PNP (voltage) logic.

Does this unit retain its elapsed timing configuration during power cuts?

Yes, configuration parameters and elapsed time states are saved securely within the internal EEPROM, designed to handle up to 100,000 rewrites.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ژاپن

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...