Optimized for high-speed, high-density thermal monitoring, the Omron NX-TS3204 is a 4-point temperature input unit designed for direct integration within NX-series PLC backplanes and distributed I/O couplers. This unit provides dedicated interface circuitry for resistance thermometers (RTDs), allowing precise calibration and temperature feedback across demanding industrial automation systems. Featuring channel-to-channel isolation and a robust, high-resolution ADC architecture, it protects vulnerable signal loops from high common-mode voltages and electrical noise common in heavy industrial facilities.

Features

  • 4 Independent Channels: Connects up to four RTD sensors to a single space-saving slice module.
  • Multi-Sensor Support: Built-in compatibility with three-wire Pt100 and Pt1000 resistance thermometers.
  • High-Speed Processing: Extremely fast input conversion time of 60 ms per unit ensures real-time thermal loop response.
  • Ultra-High Resolution: Achieves a maximum tracking resolution of 0.001 degC for critical process variables.
  • Full Electrical Isolation: Double-isolated architecture utilizing internal transformers and digital isolators between the inputs, the NX bus, and neighboring channels.
  • Toolless Termination: Features Omron push-in screwless clamping terminals for secure and vibration-resistant wiring.

Applications

  • Dynamic heat-sealing control in high-speed packaging machinery.
  • Multi-zone temperature tracking in plastic extrusion and molding profiles.
  • Precise thermal environment monitoring in climate test chambers and cleanrooms.
  • Critical pasteurization and thermal processing control in food and beverage production.

Technical Specifications Table

Parameter Specification Value
Manufacturer Omron
Model Code NX-TS3204
Module Type Temperature Input Unit (Resistance Thermometer)
Number of Inputs 4 channels
Compatible Sensors Pt100 (3-wire), Pt1000 (3-wire)
Conversion Time 60 ms / Unit
Measurement Resolution 0.001 degC max.
Input Detection Current Approx. 0.25 mA
Conductor Resistance Effect 0.06 degC/Ohm max. (Maximum allowable resistance: 20 Ohm)
I/O Refreshing Method Free-Run refreshing
Isolation Method Transformer (Power), Digital Isolator (Signal) between inputs and NX bus, plus channel-to-channel
Dielectric Strength 510 VAC for 1 minute between isolated circuits (leakage current 5 mA max)
NX Unit Power Consumption 1.45 W max. (CPU/CCU link); 1.05 W max. (Communications Coupler)
Physical Dimensions 24 mm (W) x 100 mm (H) x 71 mm (D)
Weight 0.13 kg (Net)

Empirical Engineering Insights

Alternative Models & Compatibility

The NX-TS3204 slice integrates into both local Sysmac NX1P2 / NX102 controller structures and remote I/O nodes via EtherCAT (NX-ECC) or EtherNet/IP (NX-EIC) couplers. Unlike 2-point temperature units (such as the NX-TS2204), this 4-point design utilizes high-density 16-point push-in connectors in double rows, allowing tight DIN-rail spacing but requiring carefully planned routing for the incoming sensor cables.

Application Pitfalls & Engineering Notes

To maintain the native high accuracy of 0.001 degC, engineers must avoid asymmetric wiring resistances. While 3-wire RTDs compensate for equal line resistance, mismatched conductor resistances between the A and B/B' legs directly generate measurement offsets. Keep individual lead-wire resistances strictly below 20 Ohms, and route the signal lines away from large variable frequency drives (VFDs) and high-current motor control circuits to prevent EMI-induced drift.

Commissioning & Wiring Tips

This module relies on a warm-up period of 30 minutes before system calibration routines are initiated. When connecting solid wires or stranded wires with ferrules, simply push the wire directly into the terminal without opening the clamp with a tool. When commissioning through Sysmac Studio, ensure the input filter parameters and the target sensor type (Pt100 or Pt1000) are explicitly defined in the Unit Operation Settings, as mismatched configurations will generate erratic temperature values or fault indicators.

Installation Guidelines

CRITICAL WARNING: Completely de-energize the entire control panel, including the NX-series CPU and auxiliary external power sources, before mounting, removing, or wiring the module. Working on live systems may destroy internal sensitive digital isolators or trigger unexpected controller system errors.
1

Align the NX-TS3204 unit slide-guides with the adjacent module or bus coupler on the 35mm DIN rail.

2

Firmly slide the module until the integrated locking mechanism engages with the DIN rail with an audible click.

3

Strip the temperature sensor cables to 8-10 mm or crimp them with suitable ferrules, then insert them directly into the front-facing screwless terminal block.

4

Double-check that the field shield ground is properly clamped to the functional ground strip below the DIN rail line.

Loading product navigation…

Which temperature sensors are compatible with the NX-TS3204 module?

The module natively supports Pt100 and Pt1000 three-wire resistance thermometers (RTDs).

What is the update rate and measurement resolution of this input unit?

It features a fast conversion time of 60 ms per unit with an ultra-precise temperature resolution limit of 0.001 degC.

Does the unit require an external I/O power supply?

No, it features a no-supply design and consumes current exclusively from the NX Unit power supply lines on the backplane bus.

How are the sensor channels isolated from electrical interference?

The module uses transformer isolation for power lines and digital isolators for signal paths. This isolation exists both between the inputs and the NX bus, and individually between each input channel.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ژاپن

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...