1 از 1

ProSoft MVI94-MCM MVI94 Modbus Master/Slave Communication Module

ProSoft MVI94-MCM MVI94 Modbus Master/Slave Communication Module

فقط 10 قلم(های) کالا در انبار باقی مانده است
  • تولیدکننده: ProSoft

  • شماره محصول: MVI94-MCM

  • کشور سازنده:ایالات متحده آمریکا

  • نوع محصول: Modbus Communication Modules

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 2000g

  • ابعاد: 9.4 cm x 9.4 cm x 6.9 cm

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Integrating serial Modbus connectivity directly into Allen-Bradley 1794 FLEX I/O systems is efficiently achieved using the MVI94-MCM communication module. Designed to function as a bridge between the Modbus protocol and the Rockwell Automation backplane, this module enables a host processor to interface seamlessly with field telemetry devices, SCADA systems, instruments, and PLC-based networks. The MVI94-MCM operates as either a Modbus Master or a Modbus Slave, offering versatile network configuration options for complex industrial systems.

The module occupies a single slot in the 1794 backplane and provides a reliable communication link using serial communication. It features optical isolation to protect sensitive control equipment from electrical noise and ground loop hazards. System configuration and maintenance are simplified through a dedicated, hardware-handshaking serial port, while application communications are handled via a jumper-selectable secondary port.

Features

  • FLEX I/O Compatibility: Installs directly into any standard Allen-Bradley 1794 backplane slot.
  • Dual-Port Architecture: Provides a dedicated serial configuration port (PRT1) and a multi-protocol serial application port (PRT2).
  • Protocol Versatility: Configurable as a Modbus Master or Modbus Slave device.
  • Robust Isolation: Application serial port includes 500V optical isolation from the backplane to prevent electrical noise propagation.
  • Physical Interface Selectivity: Jumper-selectable configurations on the application port support RS-232, RS-422, and RS-485 communication standards.
  • Diagnostic Diagnostics: LEDs display module status, backplane transfer, application status, and active serial port communication activity.

Applications

  • SCADA and telemetry interface integration in oil and gas pipelines.
  • Power distribution monitoring and electrical substation automation.
  • Water and wastewater remote terminal unit (RTU) coordination.
  • Inter-system PLC and DCS networking in chemical processing facilities.

Technical Specifications

Manufacturer ProSoft Technology
Part Number / Model MVI94-MCM
Series MVI94
Product Type Modbus Master/Slave Communication Module
Form Factor Single Slot 1794 Backplane compatible (any slot)
Backplane Current Load 20 mA @ 5 VDC
External Power Supply 12 to 24 VDC (340 to 170 mA)
Operating Temperature 0 to 55 degC (32 to 131 degF)
Storage Temperature -40 to 85 degC (-40 to 185 degF)
Relative Humidity 5% to 95% (without condensation)
Module Dimensions (H x W x D) 9.4 cm x 9.4 cm x 6.9 cm
Shipping Weight 2.0 kg

Connections and Interfaces

Port Designation Physical Connector Type Supported Protocols / Hardware Standards Isolation
PRT1 (Configuration Port) Mini-DIN RS-232 with Hardware Handshaking None
PRT2 (Application Port) Mini-DIN RS-232, RS-422, or RS-485 (Jumper Selectable) 500V optical isolation from backplane

Installation Guidelines

  • Terminal Base Mounting: Mount the module securely onto a compatible 1794 terminal base unit before applying power to the backplane.
  • Jumper Settings: Ensure the hardware jumper settings on the module side panel are configured correctly for the desired physical interface (RS-232, RS-422, or RS-485) prior to mounting and commissioning.
  • External Power Supply Wiring: Connect a clean 12 to 24 VDC external power source to the designated terminal base connections to power the transceiver circuits.
  • Grounding: For optimal optical isolation performance and noise reduction, ensure the terminal base and cabinet housing are properly connected to a low-impedance earth ground.
Loading product navigation…

What control platform is the ProSoft MVI94-MCM designed for?

The ProSoft MVI94-MCM is designed specifically for the Rockwell Automation 1794 FLEX I/O platform, mounting into a single backplane slot.

What are the power requirements for the MVI94-MCM module?

The module requires a 20 mA backplane current at 5 VDC, in addition to an external 12 to 24 VDC power supply drawing between 340 mA and 170 mA.

Does the application port on the module support RS-485?

Yes, the application port (PRT2) supports RS-232, RS-422, and RS-485 physical communication interfaces via jumper selection.

What is the level of isolation provided on the application port?

The application serial port (PRT2) features 500V optical isolation from the backplane to prevent noise and ground loops.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه (به جز تعطیلات رسمی) پردازش و تحویل داده می‌شوند.


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً صفحه رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ایالات متحده آمریکا

محصولات مشاهده‌شده اخیر

دانش فنی

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...