1 de 1

B&R X20DS1319 Module d'entrée numérique System X20

B&R X20DS1319 Module d'entrée numérique System X20

Il ne reste que 10 article(s) en stock
  • Fabricant : B&R

  • N° de produit : X20DS1319

  • Pays d'origine :États-Unis

  • Type de produit : Module E/S

  • Paiement : Virement bancaire, Western Union

  • Poids : 1000g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Overview of the Hardware

The X20DS1319 (X20 DS 1319) is a high-density digital input module engineered for the B&R X20 System platform. Designed to deliver deterministic signal acquisition in demanding industrial environments such as chemical processing, power generation, and high-speed packaging, this module ensures seamless integration with standard X20 backplane configurations. By providing real-time I/O status feedback and reliable electronic protection, the X20DS1319 minimizes system downtime, optimizes control loop efficiency, and guarantees high operational availability in critical automation architectures.

System Architecture and Technical Features

The module features advanced internal diagnostics and localized status monitoring via integrated LEDs. Each channel is equipped with individual functional indicators, alongside global status lights for operating state and module errors, enabling rapid field troubleshooting without external software tools. Power management is highly optimized, segregating low-power bus communication from internal I/O electronics to prevent cross-talk and maintain signal integrity. Built-in software-readable diagnostics allow predictive maintenance strategies, alerting the central controller of any performance anomalies before localized faults escalate into systemic shutdowns.

Specifications Table

Attribute Technical Data
Model X20DS1319
Brand B&R (Automation)
Origin Austria
Module Type Digital Input Module
B&R ID Code 0x2547
Status Indicators Channel I/O status, operating state, module status
Diagnostics Module run/error (LED and software), outputs status
Bus Power Consumption 0.01 W
Internal I/O Power Consumption 1.5 W
Operating Temperature 0 to 55 deg C
Dimensions 12.5 x 99 x 74 mm
Weight 0.09 kg (Module only) / 1.0 kg (Shipping weight)

Frequently Asked Questions

How does the X20DS1319 handle localized diagnostic reporting?

The module utilizes a dual-layer diagnostic framework. Field technicians can instantly verify channel status and module readiness via the front-facing LEDs. Concurrently, the module transmits real-time status registers over the X20 backplane, allowing the central PLC or DCS to log errors, monitor signal quality, and trigger automated system alerts.

Is this module hot-swappable within the X20 backplane architecture?

Yes, the X20 System architecture supports hot-swapping. The X20DS1319 can be inserted or removed from the terminal block slide-in base during active system operation without disrupting the communication of adjacent modules, significantly reducing MTTR (Mean Time To Repair).

What are the primary factors behind the difference between the net weight and the shipping weight?

The net weight of the electronic module itself is under 0.1 kg. The 1.0 kg shipping weight reflects industrial-grade protective bulk packaging, anti-static shielding bags, structural documentation inserts, and ruggedized outer boxing required to prevent mechanical or ESD damage during international transit.


Engineering Installation and Safety Field Guide

  • Bus Module Alignment and Terminal Insertion: Prior to applying control voltage, ensure the slide-in X20DS1319 module is fully seated into its corresponding X20BM11 bus module. Visual verification of the mechanical locking tabs is mandatory to prevent intermittent backplane connections or communication bus timeouts.

  • Thermal Management and Clearance: The module is designed for vertical DIN-rail mounting. Maintain a minimum clearance of 30 mm above and below the module rack to promote natural convection cooling. Ensure ambient enclosure temperatures do not exceed 55 deg C under full load conditions.

  • Shielding and Grounding Standards: To mitigate electromagnetic interference (EMI) from high-power field devices, all sensor cables must be properly shielded. Terminate the cable shields directly at the grounding busbar located at the entry point of the control enclosure using low-impedance grounding clamps.

 

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Blanc grisâtre
Country of origin
États-Unis
Power source
Alimentation DC

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...