1 de 3

Bently Nevada 140471-02 I/O Module Internal Termination

Bently Nevada 140471-02 I/O Module Internal Termination

Il ne reste que 6 article(s) en stock
  • Fabricant : Bently Nevada

  • N° de produit : 140471-02

  • Pays d'origine :États-Unis

  • Type de produit : I/O Module Internal Termination

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 200g

  • Dimensions : 24.4 mm x 241.3 mm x 99.1 mm (W x H x D)

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The Bently Nevada 140471-02 is an I/O module designed for dynamic pressure monitoring applications in the 3500 Machinery Protection System. The module processes signal inputs from high-temperature pressure transducers to perform signal conditioning and pass data to the 3500/64M main monitor board. Featuring internal termination wiring connections, the 140471-02 routes transducer signals, provides transducer power supplies, and outputs proportional +4 to +20 mA recorder signals for external control systems.

Features

  • Direct internal termination connections for 3-wire and 2-wire pressure transducer inputs
  • Integrated transducer power supply routing, providing -24 Vdc for 3-wire transducers and 3.3 mA current source at 22 Vdc nominal for 2-wire transducers
  • Support for 4-channel signal routing to the 3500/64M Dynamic Pressure Monitor
  • Dedicated terminal connections for 4 to 20 mA proportional recorder outputs per channel
  • Configurable internal jumpers for selecting 2-wire or 3-wire transducer field wiring configurations

Applications

  • Gas turbine combustion dynamic pressure monitoring
  • Hydro turbine dynamic pressure measurement
  • Reciprocating compressor cylinder dynamic pressure monitoring
  • Industrial machinery protection and condition monitoring

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Part Number 140471-02
Module Type I/O Module with Internal Termination
Compatible System Bently Nevada 3500 Series (3500/64M Dynamic Pressure Monitor)
Transducer Supplies (3-wire) -24 Vdc
Transducer Supplies (2-wire) 3.3 mA current source @ 22 Vdc (nominal)
Input Impedance (3-wire) 10 kΩ
Input Impedance (2-wire) 1.5 MΩ to 3.5 MΩ typical
Recorder Output Current +4 to +20 mA
Recorder Output Voltage Compliance 0 to +12 Vdc range across load
Recorder Output Load Resistance 0 to 600 Ω
Dimensions (H x W x D) 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Weight 0.20 kg (0.44 lb)

Connections/Interfaces

Terminal / Pin Function
PWR Transducer Power (+ / -24 Vdc supply)
COM/A Common / Signal Line A
SIG/B Signal / Line B
SHLD Cable Shield Connection
INHB Inhibit Control Input
RET1 Return / Reference Connection 1
COM Common Reference
REC1 Channel 1 Recorder Output (+4 to +20 mA)
REC2 Channel 2 Recorder Output (+4 to +20 mA)
REC3 Channel 3 Recorder Output (+4 to +20 mA)
REC4 Channel 4 Recorder Output (+4 to +20 mA)
SHIELD Main Earth Shield Termination

Installation Guidelines

  • Verify internal jumper positions for each channel pair (CH1/CH2 and CH3/CH4) match the connected transducer type (2-wire or 3-wire) prior to wiring.
  • Ensure field wiring is landed securely on the appropriate internal terminal block header (e.g., 8-position, 6-position, or push-in spring type headers).
  • Connect cable shields directly to designated SHLD/SHIELD terminals to maintain electromagnetic shielding performance.
  • Mount the module into the rear slot of the 3500 rack directly behind the corresponding 3500/64M monitor main board.

Compliance and Certifications

Certification / Standard Details
cNRTLus (without internal barriers) Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D; T4 @ Ta = -20degC to +65degC (-4degF to +149degF)
ATEX / IECEx (without internal barriers) II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20degC to +65degC (-4degF to +149degF)
EMC Directive 2014/30/EU; EN 61000-6-2, EN 61000-6-4
LV Directive 2014/35/EU; EN 61010-1
RoHS Directive 2011/65/EU
China RoHS EFUP 15 years per SJ/T 11364-2024
Maritime DNV GL rules for classification; ABS Rules Part 1
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 140471-02 I/O Module Internal Termination

Which monitor module does the unit connect to in the rack?

The module installs in the rear slot of the 3500 chassis directly behind the 3500/64M Dynamic Pressure Monitor main board.

How are field wiring configurations selected for 2-wire or 3-wire sensors?

Internal physical jumpers on the module board are positioned specifically for 2-wire or 3-wire operation across channel pairs.

What power supply voltage is provided for 3-wire pressure transducers?

The module delivers a nominal -24 Vdc power output directly to connected 3-wire transducers through the internal terminal block.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats Arabes Unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Blanc grisâtre
Country of origin
États-Unis
Power source
Alimentation DC

Produits récemment consultés

Connaissances techniques

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Modernisation des IHM Bailey INFI 90 Symphony fonctionnant sous OpenVMS Alpha

Un guide pratique pour remplacer les postes opérateur vieillissants Bailey Symphony fonctionnant sous OpenVMS Alpha. Il compare l’émulation Alpha, la migration vers OpenVMS x86, la refonte basée sur...

Pourquoi les données de maintenance sont essentielles à la fiabilité industrielle

Les données de maintenance relient les ordres de travail, les signaux des capteurs, l’historique des actifs, les coûts et les connaissances des techniciens. Lorsqu’elles sont bien exploitées, elles...

Actionneurs électriques conçus pour remplacer les systèmes de puissance fluidique : guide pratique de l’automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle des mouvements industriels en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour des applications d’automatisation industrielle

Cet article explique comment les systèmes API réalisent des opérations mathématiques essentielles telles que l’addition, la soustraction, la multiplication, la division, le modulo et l’exponentiation...