1 de 3

Bently Nevada 330750-20 High Temperature Velomitor System

Bently Nevada 330750-20 High Temperature Velomitor System

Il ne reste que 2 article(s) en stock
  • Fabricant : Bently Nevada

  • N° de produit : 330750-20

  • Pays d'origine :États-Unis

  • Type de produit : High Temperature Velomitor System

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 635g

  • Dimensions : 8.8cm x 3.6cm x 7.1cm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Option 20 (2 meters integrated hardline cable length) specifies this High Temperature Velomitor System configuration — 330750-20. This industrial piezoelectric velocity sensor segregates the sensing element from the signal conditioning electronics, enabling reliable machinery casing vibration monitoring in extreme thermal environments. With this design, the sensing head can be mounted on surfaces reaching temperatures up to 400 degC (752 degF).

By using a permanently connected integrated hardline cable, the 330750-20 eliminates intermediate connectors, which are a major source of signal loss and mechanical transducer failures in hot zones. The 2-meter cable allows the signal conditioning electronics to be positioned in a cooler location with operating temperatures from -55 degC to 121 degC (-67 degF to 250 degF) to preserve long-term reliability. This system captures high-quality casing velocity measurements comparable to standard velocity sensors but at significantly higher operating temperatures.

Features

  • Option 20 Cable Length: Includes a 2-meter integrated hardline cable connecting the sensing head directly to the conditioning electronics.
  • Extreme Temperature Support: Sensing head and hardline cable withstand operating surface temperatures up to 400 degC (752 degF).
  • Segregated Transducer Design: Places delicate signal conditioning electronics in a separate housing to run in a cooler zone.
  • Connectorless Sensor Interface: Permanent hardline cable attachment prevents connector fatigue and failure in extreme heat.
  • Nominal Velocity Output: Standard 5.7 mV/mm/s (145 mV/in/s) sensitivity for direct integration with Bently Nevada machinery protection monitors.
  • Hermetically Sealed Head: 300-series stainless steel case protects against moisture and severe industrial environments.

Applications

  • Gas and steam turbine casing vibration monitoring
  • High-temperature exhaust duct and piping analysis
  • Exhaust gas expander casing measurements
  • Boiler feed pumps and extreme-temperature rotating machinery protection

Ordering Information

Option / Segment Code on This SKU Description
Orderable Part Number 330750-20 High Temperature Velomitor System, standard mounting
A - Cable Length 20 2.0 meters (6.6 feet) of integrated hardline cable

Technical Specifications

Manufacturer Bently Nevada
Part Number / Model 330750-20
Product Type High Temperature Velomitor System
Sensitivity 5.7 mV/mm/s (145 mV/in/s) plus or minus 5% at 100 Hz
Frequency Response 15 to 2000 Hz plus or minus 3.0 dB; 20 to 1000 Hz plus or minus 0.9 dB
Sensing Head Temperature Range -55 degC to 400 degC (-67 degF to 752 degF)
Hardline Cable Temperature Range -55 degC to 400 degC (-67 degF to 752 degF)
Electronics Temperature Range -55 degC to 121 degC (-67 degF to 250 degF)
Transverse Sensitivity Less than 5% of sensitivity
Amplitude Linearity plus or minus 2% up to 152 mm/s (6 in/s) peak
Mounted Resonant Frequency Greater than 5 kHz
Output Bias Voltage -12 plus or minus 2.0 VDC nominal
Broadband Noise Floor 0.127 mm/s (0.005 in/s) rms nominal (15 Hz to 2 kHz)
Grounding Case isolated
Maximum Interconnect Cable Length 305 meters (1000 feet) with no signal degradation
Case Material 300 series stainless steel
Connector Type 2-pin Mil-C-5015 receptacle, hermetically-sealed, 304 stainless steel shell
Minimum Cable Bend Radius 51 mm (2.0 in)
Shock Survivability 24,535 m/s2 (2500 g) peak
Relative Humidity Limits To 100% non-submerged (hermetically sealed)
Weight 635 grams (1.40 lb) typical

Connections and Interfaces

Pin Designation Function / Description
Pin A Positive Signal (Velocity Output)
Pin B Signal Common / Return

Installation Guidelines

  • Cable Bend Radius: Maintain a minimum bend radius of 51 mm (2.0 in) for the integrated hardline cable to prevent internal conductor damage.
  • Environmental Protection: Position the signal conditioning electronics inside a weatherproof enclosure with wiring protected in conduit for outdoor installations.
  • Mounting Surface: Secure the sensing head to a flat, smooth, clean surface with correct torque to facilitate high-frequency vibration transfer.
  • Thermal Considerations: Verify that the signal conditioning electronics housing does not exceed its maximum operating limit of 121 degC.

Compliance and Certifications

  • ATEX Directive 2014/34/EU
  • EMC Directive 2014/30/EU
  • RoHS Directive 2011/65/EU
  • Hazardous Area Approvals (with safe barrier): Class I, Division 1, Groups A, B, C, D (T4/T1); Class I, Zone 0, Ex ia IIC T4/T1 Ga; Class I, Division 2, Groups A, B, C, D; Class I, Zone 2, Ex ec IIC T4/T1 Gc
Loading product navigation…
Key Features:

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330750-20 High Temperature Velomitor System

What does the '-20' suffix specify for the Bently Nevada 330750-20 system?

The '-20' option code specifies that this High Temperature Velomitor System is configured with a 2-meter (approx. 6.6 feet) integrated hardline cable connecting the sensing head and electronics.

What is the maximum operating temperature for the sensing head of this system?

The sensing head and the integrated hardline cable can withstand maximum operating surface temperatures of up to 400 degC (752 degF).

Why does this sensor system use a segregated design with an integrated cable?

It isolates the signal conditioning electronics from extreme machine surface temperatures, enabling the electronics to be installed in a cooler area (-55 degC to 121 degC) while eliminating intermediate connectors that often fail.

What is the nominal output sensitivity of the 330750-20?

The system provides a nominal sensitivity of 5.7 mV/mm/s (145 mV/in/s) plus or minus 5% at 100 Hz.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats Arabes Unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle de mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent les opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il couvre...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par les...