1 of 1

VFD45AMS43ANSAA | DELTA | Variateur de fréquence série MS300

VFD45AMS43ANSAA | DELTA | Variateur de fréquence série MS300

Il ne reste que 10 article(s) en stock
  • Fabricant : Delta Electronics

  • N° de produit : VFD45AMS43ANSAA

  • Pays d'origine :États-Unis

  • Type de produit : Variateur de Fréquence Série MS300

  • Paiement : Virement bancaire, Western Union

  • Poids : 8000g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Engineered to deliver high-performance vector control in complex industrial environments, the Delta Electronics VFD45AMS43ANSAA belongs to the compact, versatile MS300 Series micro-drive family. This drive is optimized for demanding applications requiring robust motor control, featuring a 45A rated output current under Heavy Duty operation and an integrated Safe Torque Off (STO) safety function to meet strict global safety requirements. Built with a space-saving design, it seamlessly supports both induction and permanent magnet motors while operating on a 460V 3-phase input power supply.

Key Features

  • Heavy Duty Overload Capacity: Rated for a 45A output current with an overload tolerance of 150% for 60 seconds.
  • Advanced Safety Integration: Built-in Safe Torque Off (STO) complying with EN ISO 13849-1 Cat 3 PL e and IEC 61508 SIL3.
  • Flexible Motor Support: Dual-control capability allows open-loop control of both traditional Induction Motors (IM) and high-efficiency Permanent Magnet (PM) synchronous motors.
  • Compact Book-Shelf Design: Standard IP20 housing allows side-by-side DIN-rail mounting to maximize control cabinet space.
  • Built-in USB Port: Facilitates direct connection to PCs for rapid configuration, commissioning, and diagnostic monitoring using Delta software.

Applications

  • High-torque machine tool spindles and metal processing hardware.
  • Industrial packaging machinery, sorting conveyors, and logistics handling.
  • Heavy-duty pumping systems and high-volume HVAC air handling units.
  • Precision textile production systems and automated woodworking machinery.

Technical Specifications

Parameter Value
Manufacturer Delta Electronics
Model Number VFD45AMS43ANSAA
Series MS300 (Standard Micro Drive)
Rated Input Voltage 460V AC (3-Phase)
Rated Output Current 45A (Heavy Duty, 150% overload for 60 seconds)
Enclosure Rating IP20 (Standard Housing)
Integrated EMC Filter None (No Function Code: N)
Safety Standard Built-in STO (SIL3 / PL e)
Control Modes V/F, SVC (Sensorless Vector Control) for both IM and PM
Physical Unit Weight 6.25 kg
Shipping Weight (Calculated) 8.00 kg

Connections and Interfaces

Terminal Block Designation Functional Assignment / Description
R/L1 - S/L2 - T/L3 3-Phase AC power supply input terminals
U/T1 - V/T2 - W/T3 AC motor output terminals (Induction or PM)
+1 - +2 / B1 - B2 Connections for DC reactor and external dynamic braking resistors
STO1 - STO2 - DCM Dual-channel Safe Torque Off inputs and signal common
RA - RB - RC Multi-function relay output (Form C)

Alternative Models & Compatibility

When upgrading older Delta VFD-E or VFD-M series drives to the modern MS300 series, verify physical cabinet mounting constraints since the MS300 is significantly narrower. Parameter files can be migrated through Delta VFDSoft, but auto-tuning should be re-executed on the MS300 platform to ensure the sensorless vector algorithms accurately map the winding resistance of older motors.

Application Pitfalls & Engineering Notes

Because this is the "N" designated model, it lacks a built-in EMC filter. If you are operating this drive in environments with sensitive instrumentation, digital load cells, or high-speed serial communications, you must install an external line filter on the input side and use fully shielded motor cables to mitigate high-frequency electromagnetic noise. Ensure the carrier frequency parameter is adjusted appropriately to maintain low thermal load inside sealed non-ventilated enclosures.

Commissioning & Wiring Tips

During initial commissioning, if the drive is not wired to an external emergency safety relay, the STO1 and STO2 terminals must be jumpered to the common reference (+24V / DCM) using the factory-provided shorting clips. Leaving these terminals open will cause the drive to display continuous safety fault states (STL1 or STL2) and block output power initialization. Ground the motor shield directly to the drive's chassis ground lug to prevent ground-loop current injection.

Installation Guidelines

CRITICAL WARNING: Prior to undertaking any physical wiring or terminal alterations, disconnect all primary supply power. Allow a minimum of 10 minutes for internal DC bus capacitors to discharge fully. Use a calibrated multimeter to confirm that voltage between the + and - terminals is under 36V DC before commencing work.
1

Mount the variable frequency drive vertically on a flat, vibration-free surface, maintaining a minimum of 50mm clearance above and below the cooling fan housing to ensure unobstructed convection airflow.

2

Verify that the source supply voltage aligns strictly with the 460V AC 3-phase input requirements. Connect input power to R/L1, S/L2, and T/L3 terminals using correctly sized copper conductors rated for at least 75 degC.

3

Connect the motor leads to terminals U/T1, V/T2, and W/T3. Do not apply main AC power to these output terminals, as this will result in immediate catastrophic failure of the drive's internal IGBT power bridge.

Loading product navigation…

What is the overload rating of the MS300 series 45A drive?

This drive features a Heavy Duty rating of 45A with an overload capability of 150% of rated current for up to 60 seconds.

Does this drive include a built-in EMC filter?

No, this model features the 'N' suffix in its part number, indicating it has no built-in EMC filter. External filtering must be installed if electromagnetic noise suppression is required.

How do I clear the STL1 or STL2 safety fault code upon startup?

The STL1 and STL2 codes indicate that the Safe Torque Off (STO) terminals are open. To enable drive operation, the STO1 and STO2 terminals must be wired to a safety relay or shorted to the +24V common terminal using factory jumpers.

Can this unit control permanent magnet synchronous motors?

Yes, the MS300 control loop natively supports both standard Induction Motors (IM) and Permanent Magnet (PM) synchronous motors in open-loop vector control mode.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...