1 de 1

DELTA VFD037E43T Série VFD-E Variateur de fréquence 3,7 kW

DELTA VFD037E43T Série VFD-E Variateur de fréquence 3,7 kW

Il ne reste que 10 article(s) en stock
  • Fabricant : Delta Electronics

  • N° de produit : VFD037E43T

  • Pays d'origine :États-Unis

  • Type de produit : Variateur de fréquence

  • Paiement : Virement bancaire, Western Union

  • Poids : 1900g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Overview & Operational Value

The VFD037E43T (VFD037E43T) is a modular, sensorless vector AC inverter drive engineered for high-efficiency speed and torque regulation of three-phase induction motors. Rated for a 5 HP (3.7 kW) motor capacity, this precision variable frequency drive is widely deployed across critical industrial applications, including commercial HVAC blower systems, centrifugal water pumps, automated conveyor lines, and material handling cranes.

By executing real-time flux vector calculations, the drive maximizes low-speed output torque while maintaining high speed stability. This dynamic regulation optimizes power consumption, prevents motor insulation breakdown caused by voltage spikes, and ensures uninterrupted throughput across continuous manufacturing processes.

Architecture & Hardware Configuration

Operating on a 460 V three-phase grid, this VFD-E Series unit features a modular hardware architecture that supports flexible side-by-side DIN-rail mounting to optimize enclosure layout efficiency. The "T" specification signifies a Frame A chassis layout equipped with an integrated internal brake chopper circuit.

This embedded chopper allows technical personnel to wire a dynamic braking resistor directly to the power terminals, enabling the drive to manage high-inertia deceleration ramps without experiencing overvoltage faults. The unit incorporates a removable keypad, an easily accessible cooling fan, and standard RS-485 Modbus RTU communication interfaces for seamless integration into industrial fieldbus networks.

Technical Performance Matrix

Parameter Specification Details
Model VFD037E43T
Brand DELTA
Origin Taiwan
Drive Category Variable Frequency Drive (VFD)
Series Platform VFD-E
Applicable Motor Capacity 3.7 kW (5 HP)
Mains Input Voltage 460 VAC, 3-phase (50/60 Hz)
Output Frequency Range 0.1 to 600 Hz
Control Method V/f Control, Sensorless Vector Control (SVC)
Chassis Framework Frame A, Built-in Brake Chopper
Communication Interface RS-485 (Modbus RTU)
Enclosure Protection IP20
Dimensions 142 mm x 72 mm x 152 mm
Weight 1.9 kg (Shipping Weight: 3.5 kg with reinforced packaging)
Ambient Temperature Limit -10 to +50 deg C (Non-condensing)

Engineering Queries & Diagnostic Methods

  • What parameter configurations are necessary to activate the integrated brake chopper?

    The internal hardware chopper triggers automatically when the DC bus voltage exceeds the pre-set braking threshold. However, you must enable dynamic braking in the drive's parameter architecture (typically via parameter group 01) and define the maximum allowable braking duty cycle to prevent thermal overloading of the external resistor matrix.

  • How is the sensorless vector control mode calibrated for a generic 3.7 kW motor?

    To achieve optimal torque response, decouple the motor shaft from the mechanical load and execute a dynamic auto-tuning routine. Input the motor's nameplate parameters—including rated voltage, frequency, base current, and rated speed—into the drive memory. The VFD will measure stator resistance and mutual inductance to optimize its internal vector control loop.

  • What corrective actions are required if the drive continuously trips on an Overcurrent (OC) fault during startup?

    An overcurrent fault during acceleration indicates that the programmed acceleration ramp time is too short for the inertia of the load, or the V/f torque boost curve is set too high. Increase the acceleration time parameter, inspect the motor windings for phase-to-phase insulation breakages, and verify that the mechanical load turns freely without binding.


Field Commissioning & Safety Protocols

Power Circuit Protection and Wiring Architecture

Connect the 460 VAC incoming three-phase utility lines exclusively to terminals R, S, and T. Connecting incoming line power to output terminals U, V, and W will cause instantaneous catastrophic failure of the internal insulated-gate bipolar transistors (IGBTs). Install a properly sized three-phase molded case circuit breaker (MCCB) upstream of the drive to provide high-capacity thermal and magnetic short-circuit protection.

Braking Resistor Deployment and Safe Thermal Routing

When installing an external dynamic braking resistor across the B1 and B2 terminals, ensure the resistor assembly is mounted in a vertical metal housing separate from the primary control enclosure. Dynamic braking elements generate substantial thermal dissipation during cyclic deceleration; routing these units away from the drive prevents the rising hot air from artificially raising the VFD intake temperature above its 50 deg C ambient limit.

Control Signal Isolation and Grounding Procedures

Run all low-voltage control lines—such as 0-10 V analog speed references or 24 VDC digital start/stop commands—in a separate wiring tray away from the motor power leads. Use double-shielded twisted-pair (STP) cabling for all analog signals. Terminate the cable shield to the designated control ground terminal on the drive side only, leaving the field side floating to avoid creating ground loops that degrade speed reference tracking.

 

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Blanc grisâtre
Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...