1 de 2

Assemblage de câble d'extension inférieur série M DeltaV Emerson KJ4002X1-BF2 (12P3866X012)

Assemblage de câble d'extension inférieur série M DeltaV Emerson KJ4002X1-BF2 (12P3866X012)

Il ne reste que 8 article(s) en stock
  • Fabricant : Emerson

  • N° de produit : KJ4002X1-BF2 12P3866X012

  • Pays d'origine :États-Unis

  • Type de produit : Câble d'extension inférieur

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 500g

  • Dimensions : 136 cm x 7 cm x 2 cm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Product Overview

The Emerson KJ4002X1-BF2 (alternatively identified by part number 12P3866X012) is a 1.2-meter, 44-pin Bottom Extender Cable Assembly specifically designed for the DeltaV™ M-series I/O Subsystem. This hardware component facilitates the expansion of the LocalBus between horizontal carriers, allowing for flexible physical layouts within DCS (Distributed Control System) cabinets. It is engineered to carry high-current LocalBus circuit power (12.6 VDC at 15 A) and high-speed communication signals across carrier segments.

Designed for demanding industrial environments, the KJ4002X1-BF2 is rated for Class G3 harsh environments per ISA-S71.04-1985, ensuring resistance against corrosive airborne contaminants. It is primarily utilized in large-scale process automation projects where I/O density requires multiple carriers and multi-enclosure configurations. The cable's robust design ensures signal integrity and power stability across the 6.5-meter maximum allowable LocalBus extension limit.

Technical Configuration

Attribute Details
Model KJ4002X1-BF2
Alternate Part No. 12P3866X012
Brand Emerson / DeltaV
Product Type Extender Cable Assemblies
Series M-series I/O Subsystem
Pin Configuration 44-pin
Cable Length 1.2 Meters
LocalBus Voltage 12.6 VDC
Current Rating 15 A
Operating Temperature -40 to 70°C
Relative Humidity 5 to 95% Non-Condensing
Protection Rating IP 20
Contaminant Protection ISA-S71.04-1985 Class G3
Shock/Vibration 10g ½ Sinewave (11 msec) / 0.5g (16 to 150Hz)

Ordering Information

Industrial procurement and replacement should reference both the model number and the alternate part number to ensure exact hardware matching within the DeltaV ecosystem.

Model Number Alternate Part No. Description
KJ4002X1-BF2 12P3866X012 1.2m Bottom Extender Cable for Horizontal Carriers

Engineering & Installation Guide

Mandatory Power Sequencing:

The KJ4002X1-BF2 is not designed for "hot-swapping." This unit cannot be removed or inserted while the system power is energized. System power must be fully de-energized before disconnecting carriers or LocalBus extender cables to prevent hardware damage or unpredictable controller behavior.

LocalBus Length Constraints:

Total bus integrity is strictly dependent on cable length. The cumulative length of all I/O carriers and LocalBus Extenders in a single segment must not exceed 6.5 meters. Exceeding this limit will result in excessive voltage drop on the 12.6 VDC rail and potential signal timing errors.

Conduit and Routing Requirements:

When the KJ4002X1-BF2 is used to interconnect carriers across different enclosures, the cable must be installed within a dedicated conduit to ensure physical protection and EMC shielding. Proper separation between LocalBus cables and high-voltage AC power lines is required to prevent electromagnetic interference.

Hazardous Area Compliance:

For installations in Zone 2 hazardous areas, technicians must strictly adhere to document 12P2046 "DeltaV™ Scalable Process System Zone 2 Installation Instructions." Ensure the area is known to be non-hazardous before any physical disconnection.


Maintenance & Troubleshooting FAQ

Q: Is calibration required for the KJ4002X1-BF2?

A: No. The cable is a passive electromechanical assembly and requires no calibration or software adjustment.

Q: How do I handle a suspected cable failure?

A: This unit contains no user-serviceable parts. If the 12.6 VDC LocalBus power is absent at the downstream carrier or if I/O modules are failing to initialize, check the 44-pin seating and locking mechanisms. If the cable is physically damaged, it must be replaced as an entire assembly.

Q: Are KJ4002X1-BF2 and 12P3866X012 fully interchangeable?

A: Yes. 12P3866X012 is the internal Emerson manufacturing/engineering part number associated with the KJ4002X1-BF2 model designation. They refer to the same physical cable assembly.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Noir
Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...