1 of 3

Module E/S Virtuel Emerson VIM-4201

Module E/S Virtuel Emerson VIM-4201

Il ne reste que 4 article(s) en stock
  • Fabricant : Emerson

  • N° de produit : VIM-4201

  • Pays d'origine :États-Unis

  • Type de produit : Module d'E/S virtuel

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 280g

  • Dimensions : 4.1cm x 12.5cm x 15.8cm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The Emerson VIM-4201 is a Virtual I/O Module network gateway designed to provide a native DeltaV I/O interface to open plant Ethernet networks and devices. This module enables DeltaV Controllers to read and write signals from plant floor devices operating on Ethernet networks, including programmable logic controllers (PLCs), Motor Control Centers, and weigh scales. The VIM-4201 is specifically designed for redundant installations, allowing two modules to be set up as a redundant pair to provide backup plant network capabilities. It emulates DeltaV Serial Cards, allowing seamless integration where the DeltaV Controller auto-senses the gateway directly within the DeltaV system architecture.

Features

  • Emulates up to 4 DeltaV Serial Cards and supports up to 128 Serial Card Datasets.
  • Provides automated integration with the DeltaV auto-sense I/O function.
  • Supports 1:1 module redundancy with automatic or manual switchover capabilities managed via DeltaV Diagnostics.
  • Equipped with a standard 10BaseT 8-pin RJ-45 connector for external plant Ethernet interface.
  • Features an intuitive setup interface through the VIMNet Explorer Utility with graphical drag-and-drop network configuration.

Applications

  • Redundant network gateway mirroring for open plant Ethernet networks.
  • Interfacing DeltaV Controllers with plant floor PLCs.
  • Motor Control Center status monitoring and control data routing.
  • Process weigh scale integration over Modbus TCP/IP or EtherNet/IP protocols.

Ordering Information

Item Description
VIM-4201

 

DeltaV Virtual I/O Module for Redundant Installations 

MIM-4207 DeltaV Virtual I/O Module 
IOD-4101 Modbus TCP/IP Master Driver for DeltaV VIM 
IOD-4102 Ethernet/IP Scanner Driver for DeltaV VIM 
IOD-4104 Generic Device Ethernet / IP Scanner Driver for DeltaV VIM 

Technical Specifications

Parameter Specification
Power Requirement Supplied by System Power Supply through 2-wide Power/Controller Carrier 
Maximum Current 2.0 A 
Fuse Protection 3.0 A, non-replaceable fuses 
Power Dissipation 4.0 W typical, 5.4 W maximum 
VIM User Memory 16 MB 
External Network Interface One 10BaseT 8-pin RJ-45 Connector 
Emulated Cards Capacity 4 Emulated DeltaV Serial Cards 
Dataset Capacity 128 data sets per VIM (32 per Emulated Card) 
Node Capacity (Redundant Mode) 16 slaves only 
Operating Temperature 0 to 60 degC (32 to 140 degF) 
Storage Temperature -40 to 85 degC (-40 to 185 degF) 
Relative Humidity 5 to 95%, non-condensing 
Airborne Contaminants ISA-S71.04-1985 Airborne Contaminants Class G2 
Shock 10 g, 1/2-sine wave for 11 ms 
Vibration 1 mm peak-to-peak from 5 Hz to 16 Hz, 0.5 g from 16 Hz to 150 Hz 

Connections/Interfaces

LED Indicator ON Status Description
Green -- Power Indicates DC power is applied 
Red -- Error Indicates an error condition 
Green -- Active Indicates that the VIM is commissioned and active 
Green -- Standby Not used 
Yellow Flashing -- Network Indicates valid network communication 
Yellow Flashing - Ctlr I/O Indicates valid DeltaV I/O Bus communication 

Installation Guidelines

  • Mounting Location: Install the module on its own 2-wide carrier to the left-hand-side of the DeltaV controller.
  • Power Provision: Ensure each module is supported by a dedicated system power supply connected via the carrier side connector.
  • Network Wiring: Establish communication connections to the plant Ethernet network using the integrated RJ-45 Ethernet port on the module face.
  • Redundant Configuration: Wire the primary and standby modules such that they can monitor each other continuously with status commands across the common Ethernet Network.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Module E/S Virtuel Emerson VIM-4201

How many DeltaV Serial Cards does the device emulate?

The device emulates up to 4 DeltaV Serial Cards and supports a maximum of 128 Serial Card Datasets.

What are the exact operating temperature limits for the module?

The operating temperature range for the module is from 0 to 60 degC.

What is the maximum power dissipation of the communication module?

The typical power dissipation is 4.0 W, and the maximum power dissipation is 5.4 W.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...