1 of 1

FS-DCOM-232/485 | Honeywell | Module d'interface de communication

FS-DCOM-232/485 | Honeywell | Module d'interface de communication

Il ne reste que 3 article(s) en stock
  • Fabricant : Honeywell

  • N° de produit : FS-DCOM-232/485

  • Pays d'origine :États-Unis

  • Type de produit : Communication Interface Modules

  • Paiement : Virement bancaire, Western Union

  • Poids : 2000g

  • Dimensions : 110 x 70 x 61 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Facilitating seamless serial communication within industrial process safety networks, the FS-DCOM-232/485 serves as a dedicated communication interface module developed by Honeywell. This module establishes a reliable bridge between control processors and peripheral systems, translating signal levels across standard serial interfaces to ensure secure, real-time data flow. Designed for integration within Honeywell safety-related control architectures, the module manages signal physical-layer conversion with high noise immunity and minimal latency.

The unit supports dual-protocol configurations, allowing operators to interface via either RS-232 or high-speed RS-485/422 networks. Power is drawn directly from the system control processor, eliminating the need for external power supplies and simplifying cabinet wiring. Its compact footprint and standardized DIN rail mounting design make it suitable for high-density cabinet layouts in critical infrastructure installations.

Features

  • Dual interface compatibility supporting both EIA/TIA-232 and EIA/TIA-485-A physical layers.
  • Direct backplane power configuration via the system's Control Processor.
  • High-speed serial data transmission with support for multiple coding methods including transparent, FM0, FM1, and Manchester coding.
  • Rugged, industrial-grade housing engineered for DIN rail installations.
  • Galvanic isolation and signal conditioning for reliable performance in electrically noisy environments.

Applications

  • Safety Instrumented Systems (SIS) and Fail-Safe Control (FSC) networks.
  • Integration of safety PLCs with distributed control systems (DCS) and SCADA hosts.
  • Industrial monitoring networks in oil and gas, petrochemical, and power generation sectors.
  • Interface connections to remote terminal units (RTUs), flow computers, and gas chromatographs.

Technical Specifications

Manufacturer Honeywell
Part Number / Model FS-DCOM-232/485
Module Type Communication Interface Module
Input Voltage 5 Vdc (+/-5%)
Input Current Max 500 mA (supplied by the Control Processor)
RS-232 Output Levels According to EIA/TIA-232 standards
RS-232 Baud Rate 0 to 250 kBaud
RS-485/422 Output Levels According to EIA/TIA-485-A standards
RS-485/422 Baud Rate 0 to 2 MBaud (supports transparent, FM0, FM1, or Manchester coding)
Mounting Options DIN EN rails: TS32 / TS35 x 7.5
Required Rail Length 117 mm (4.6 in)
Module Dimensions (L x W x H) 110 x 70 x 61 mm
Terminal Dimensions (L x W x H) 6 x 57 x 47 mm
Shipping Weight 2.0 kg

Installation Guidelines

When installing the module, mount the unit horizontally on a standard TS32 or TS35 x 7.5 DIN rail. Ensure a minimum of 117 mm of continuous rail length is allocated to accommodate the module and its terminal connections. To prevent thermal buildup, maintain adequate ventilation spacing of at least 20 mm above and below the module housing. All serial interface cables must be shielded, with the shield terminated to the local cabinet ground point to prevent electromagnetic interference.

Compliance and Certifications

  • CE Mark
  • TUV Rheinland Certified for Safety-Related Systems
  • UL Listed
  • FM Approved
Loading product navigation…

What is the primary function of the Honeywell FS-DCOM-232/485?

The FS-DCOM-232/485 is a communication interface module that converts and interfaces serial signals between RS-232 and RS-485/422 protocols for Honeywell control systems.

Does this communication module require an external power supply?

No. The module is powered directly by the host system's Control Processor, requiring a 5 Vdc (+/-5%) input voltage at a maximum current of 500 mA.

What maximum transmission speeds does the RS-485/422 interface support?

The RS-485/422 interface supports baud rates from 0 to 2 MBaud and is compatible with transparent, FM0, FM1, or Manchester coding.

Which DIN rails are compatible with the FS-DCOM-232/485?

The module is compatible with standard DIN EN rails TS32 and TS35 x 7.5, requiring a minimum rail length of 117 mm.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...