1 de 1

CJ1W-DA041 | Omron | Unité de sortie analogique

CJ1W-DA041 | Omron | Unité de sortie analogique

Il ne reste que 5 article(s) en stock
  • Fabricant : Omron

  • N° de produit : CJ1W-DA041

  • Pays d'origine :Japon

  • Type de produit : Unité de sortie analogique

  • Paiement : Virement bancaire, Western Union

  • Poids : 150g

  • Dimensions : 31 x 90 x 65 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for precise digital-to-analog signal conversion within industrial automation systems, the CJ1W-DA041 serves as a high-performance analog output module for the Omron CJ series. This module enables programmable controllers to interface directly with analog control devices by converting digital process values into corresponding voltage or current signals.

Equipped with four high-accuracy channels, the CJ1W-DA041 supports standard industrial output ranges including 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, and 4 to 20 mA. It features a removable 18-point terminal block that facilitates direct wiring and convenient system maintenance, minimizing downtime during module replacement.

Features

  • Four independent, configurable analog output channels.
  • Supports multiple voltage and current output ranges for broad instrument compatibility.
  • Fast digital-to-analog conversion period of 1.0 ms per point.
  • Photocoupler isolation between backplane controller signals and output circuits.
  • Configurable output hold function to maintain, clear, or maximize output signal states during PLC stop or error conditions.
  • Removable 18-point M3 screw terminal block for streamlined installation and wiring.

Applications

  • Proportional valve positioning and control systems.
  • Variable frequency drive (VFD) speed regulation.
  • Process controllers, chart recorders, and remote indicators.
  • Multi-axis motion profiling and industrial heating control loops.

Technical Specifications

Parameter Value
Manufacturer Omron
Part Number/Model CJ1W-DA041
Module Type Analog Output Unit (CJ-series Special I/O Unit)
Number of Analog Outputs 4
Output Signal Range (Voltage) 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V
Output Signal Range (Current) 4 to 20 mA
Output Impedance (Voltage) 0.5 ohm max.
Maximum Output Current (Voltage) 12 mA
Maximum Permissible Load Resistance (Current) 600 ohm
Resolution 4,000 (16-bit binary set data)
D/A Conversion Period 1.0 ms per point
Accuracy (at 25 degC) Voltage: +/-0.3% of F.S. | Current: +/-0.5% of F.S.
Accuracy (at 0 degC to 55 degC) Voltage: +/-0.5% of F.S. | Current: +/-0.8% of F.S.
Isolation Photocoupler between I/O and Controller signals (No isolation between individual I/O channels)
Power Consumption 140 mA max. at 5 VDC
External Power Supply Requirements 24 VDC, 200 mA max. (Inrush current: 20 A max., pulse width: 1 ms min.)
External Terminals 18-point detachable terminal block (M3 screws)
Dimensions 31 x 90 x 65 mm (W x H x D)
Weight 150 g max.

Installation Guidelines

  • Always disconnect the power supply to the CJ-series PLC rack before mounting or removing the analog output module.
  • To prevent electromagnetic noise, use shielded twisted-pair cables for all analog output connections and ground the shield only at the receiving end.
  • Route analog signal wires through dedicated conduits separate from high-voltage cables and AC power lines.
  • Ensure the external 24 VDC power supply complies with the startup inrush current specifications (20 A peak) to prevent power drops during module initialization.
Loading product navigation…

What is the conversion speed of the CJ1W-DA041?

The D/A conversion period for the CJ1W-DA041 is 1.0 ms per point.

Does the CJ1W-DA041 support individual channel isolation?

No. While the module features photocoupler isolation between the I/O signals and the controller logic, there is no isolation between the individual output channels.

What happens to the analog outputs when the PLC controller stops?

The module features an output hold function. Depending on your configuration, it can hold the last state, clear the output (CLR), or set the output to maximum values (MAX).

Can the CJ1W-DA041 output both voltage and current simultaneously?

Yes, each of the 4 channels can be configured independently for either voltage (e.g., 0 to 10 V) or current (e.g., 4 to 20 mA) output ranges.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...