1 de 1

Unité de sécurité flexible Omron G9SX-AD322-T150-RC série G9SX

Unité de sécurité flexible Omron G9SX-AD322-T150-RC série G9SX

Il ne reste que 2 article(s) en stock
  • Fabricant : Omron

  • N° de produit : G9SX-AD322-T150-RC

  • Pays d'origine :Japon

  • Type de produit : Unités de sécurité flexibles

  • Paiement : Virement bancaire, Western Union

  • Poids : 1500g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Facilitating safe system expansion and precise timing control across complex machine layouts, the Omron G9SX-AD322-T150-RC flexible safety unit delivers advanced safety logic integration without complex programming. This advanced safety controller features solid-state safety outputs configured for both instantaneous shut-off and controlled deceleration profiles. Built with a spring-cage terminal interface, the hardware ensures gas-tight, vibration-proof electrical terminations ideal for high-stress manufacturing environments.

Features

  • Configurable OFF-delay times up to 150 seconds via synchronized front-panel rotary dials.
  • Three instantaneous solid-state safety outputs and two OFF-delayed safety outputs for staged system shutdowns.
  • Spring-cage (tension clamp) terminal blocks for rapid installation and long-term connection reliability.
  • Two auxiliary outputs providing clear diagnostics and machine status communication directly to control PLCs.
  • Logical AND connection capability to cascade multiple safety units while preserving safety integrity levels.

Applications

  • Robotic work cell safety integration requiring delayed interlocking guard access until complete arm deceleration.
  • Emergency stop circuits necessitating controlled motor ramp-down prior to physical brake application.
  • Complex packaging line synchronization requiring zoned safety shutdown capabilities.
  • Safety light curtain integration paired with automated process gates.

Technical Specifications

Manufacturer Omron
Model Reference G9SX-AD322-T150-RC
Unit Classification Advanced Safety Unit
Rated Supply Voltage 24 VDC
Operating Voltage Range 20.4 to 26.4 VDC (-15% to +10% of nominal)
Power Consumption 4.0 W maximum
Instantaneous Safety Outputs 3 Semiconductor (P-channel MOS FET)
OFF-delayed Safety Outputs 2 Semiconductor (P-channel MOS FET)
Auxiliary Outputs 2 PNP Transistor (100 mA maximum)
Max. OFF-delay Configuration 150 seconds
Load Current (1 to 2 active outputs) 1.0 A DC maximum per output
Load Current (3 or more active outputs) 0.8 A DC maximum per output
Safety Input Impedance Approximately 2.8 kOhms
Connection Style Spring-cage terminals (RC model)
Vibration Resistance 10 to 55 to 10 Hz, 0.375 mm single amplitude
Net Unit Weight 0.2 kg
Shipping Weight 1.5 kg

Connections and Interfaces

Terminal Block Designation Functional Circuit Assignment
A1, A2 Power supply connections (24 VDC and 0 VDC reference)
T11, T12 / T21, T22 Dual-channel safety sensor/switch inputs
T31, T32 Feedback loop and manual reset inputs
S14, S24, S34 Instantaneous safety semiconductor outputs
S44, S54 OFF-delayed safety semiconductor outputs
Y1, Y2 Auxiliary solid-state outputs for diagnostic communication

Empirical Engineering Insights

Alternative Models & Compatibility

The G9SX-AD322-T150-RC features spring-cage terminals, which represent the direct structural and electrical alternative to the G9SX-AD322-T150-RT model (which utilizes traditional screw terminals). Because both variants share an identical internal logic engine and mounting footprint, they are completely interchangeable from a system engineering standpoint. However, the terminal plugs themselves cannot be directly cross-connected due to physical housing differences; wiring must be re-terminated with ferrules for optimal performance in the RC unit.

Application Pitfalls & Engineering Notes

When configuring the OFF-delay timing on the G9SX-AD322-T150-RC, engineers must adjust both rotational switches on the front panel to the exact same delay coefficient. If the two dials do not match precisely, the unit detects an asymmetrical layout parameter and enters a lock-out fault status, disabling all safety outputs. To reset this fault condition, set both dials to identical configurations and cycle the main 24 VDC supply voltage.

Commissioning & Wiring Tips

For optimal termination reliability, utilize insulated wire ferrules with a crimp length of 10 mm. Avoid using bare stranded copper wire in the spring-cage terminals, as single stray strands can cause local resistance faults or physical short-circuits. Utilize a 2.5 mm flat-head screwdriver inside the actuation slot to open the internal tension clamp during termination or diagnostic procedures.

Installation Guidelines

CRITICAL WARNING: Prior to attempting installation, configuration, or physical wiring adjustments on the safety unit, isolate and lock out all upstream electrical power sources. Verify the absence of residual voltage across all power and output lines before proceeding to avoid severe electrical hazards.
  1. 1
    DIN-Rail Mounting: Snap the safety unit securely onto standard 35 mm DIN rail inside a protective electrical enclosure rated for the application environment (minimum IP54 rating recommended).
  2. 2
    Terminal Block Connection: Insert the designated ferruled wire leads into the spring-cage terminals by depressing the adjacent actuation slot using a dedicated 2.5 mm flat tool.
  3. 3
    Time-Delay Calibration: Configure the integrated rotary switches to align with the desired machine deceleration delay profile, ensuring both front-panel dials are dialed to the identical numeric value.
  4. 4
    Functional System Test: Energize the module, verify the green LED diagnostic indications, and execute a controlled system verification test to confirm active-low safety response profiles.

Que se passe-t-il si les deux cadrans rotatifs de temporisation OFF ne correspondent pas ?

S'il y a une discordance de réglage entre les deux cadrans sur le panneau avant, l'unité de sécurité l'identifie comme un paramètre de configuration asymétrique. Cela place l'unité en mode de défaut de verrouillage, désactivant immédiatement toutes les sorties de sécurité. Les deux cadrans doivent être identiques et l'alimentation doit être coupée puis rétablie pour effacer cet état.

Puis-je remplacer une unité G9SX-AD322-T150-RT par cette variante RC ?

Oui. Le G9SX-AD322-T150-RC est électriquement identique au modèle -RT et partage exactement les mêmes fonctions logiques. La seule différence physique est que la variante 'RC' dispose de bornes à ressort, tandis que la variante 'RT' dispose de bornes à vis.

Quelles sont les limites de charge de sortie lorsque plusieurs sorties à semi-conducteurs sont actives ?

Lors de l'utilisation de 2 sorties ou moins, chaque sortie peut supporter un courant de charge maximal de 1,0 A DC. Lors de l'utilisation simultanée de 3 sorties de sécurité ou plus, le courant de charge maximal autorisé diminue à 0,8 A DC par sortie pour éviter une surcharge thermique.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...