1 de 1

Rideau lumineux de sécurité Omron F3SJ-E0465N25 série F3SJ

Rideau lumineux de sécurité Omron F3SJ-E0465N25 série F3SJ

Il ne reste que 4 article(s) en stock
  • Fabricant : Omron

  • N° de produit : F3SJ-E0465N25

  • Pays d'origine :Japon

  • Type de produit : Rideaux lumineux de sécurité

  • Paiement : Virement bancaire, Western Union

  • Poids : 3000g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Engineered to deliver simplified, Type 4 machine guarding in automated environments, the Omron F3SJ-E0465N25 provides reliable optoelectronic presence sensing. This Easy-type (F3SJ-E) safety light curtain features a 465 mm protective height and a 25 mm detection capability specifically optimized for hand protection. It operates on an NPN output configuration, making it compatible with sinking logic safety controllers and relays. By focusing on essential on-off safety functions, it minimizes wiring complexity and setup time while maintaining compliant industrial safeguarding performance.

Key Features

  • Type 4 Safety Rating: Compliant with international safety standards including EN ISO 13849-1 PL e and IEC 61508 SIL3.
  • Optimized Resolution: 25 mm beam gap designed specifically for reliable hand and arm detection.
  • NPN Output Architecture: Twin NPN solid-state outputs (OSSDs) for seamless integration with sinking control systems.
  • Simplified Wiring: Reduced wiring design using standard M12 connections, omitting complex auxiliary functions to prevent field configuration errors.
  • Robust Optical Range: Operating scanning range of 0.2 m to 7.0 m, covering a wide array of machine entry points.

Applications

  • Robotic Workcells: Guarding primary access areas and perimeter entry points of robotic arms.
  • Packaging and Conveying: Presence detection and worker protection around automated palletizers and cartooning systems.
  • Assembly Lines: Point-of-operation safeguarding on semi-automated workstations and pneumatic presses.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number F3SJ-E0465N25
Series Type F3SJ-E (Easy Type)
Safety Category Type 4, PL e, SIL 3
Protective Height 465 mm
Detection Capability 25 mm diameter (Hand)
Number of Beams 22
Beam Gap 20 mm
Operating Range 0.2 m to 7.0 m
Output Type NPN (x2 OSSD outputs)
Supply Voltage (Vs) 24 VDC plus/minus 20% (SELV/PELV)
Light Source Infrared LED (870 nm)
Current Consumption (Emitter) 41 mA max.
Current Consumption (Receiver) 40 mA max.
Enclosure Rating IP65 (IEC 60529)
Net Weight 1.8 kg
Shipping Weight (Calculated) 3.0 kg

Connections and Interfaces

M12 Connector Pin Emitter Function Assignment Receiver Function Assignment
Pin 1 (Brown) +24 VDC Power Input +24 VDC Power Input
Pin 2 (White) Not Used (NC) OSSD 2 Output
Pin 3 (Blue) 0 VDC Power Input 0 VDC Power Input
Pin 4 (Black) Test Input OSSD 1 Output

Empirical Engineering Insights

Alternative Models & Compatibility

The F3SJ-E "Easy" series is designed for straightforward on-off detection. Unlike the Advanced (F3SJ-A) and Basic (F3SJ-B) series, the F3SJ-E series does not support series connection (cascading) for multi-sided safety fields. Emitters and receivers must be replaced in identical matched pairs; pairing an F3SJ-E emitter with an F3SJ-B receiver will result in a synchronization fault. Always verify the prefix/suffix matches during drop-in replacements to prevent field pairing errors.

Application Pitfalls & Engineering Notes

Because this model features NPN outputs (N25 suffix), it cannot be wired directly to PNP-only safety monitoring modules. Integrating this light curtain into a PNP-based system requires an external NPN-to-PNP converter or a dedicated safety relay compatible with dual sinking inputs. Additionally, ensure the structural mounting is completely rigid; thermal expansion or frame vibrations can easily disrupt optical alignment across the 7.0-meter operating threshold, triggering intermittent OSSD dropouts.

Commissioning & Wiring Tips

To maintain complete electromagnetic immunity, execute correct shielding procedures. The cable shield must be grounded at the control panel chassis. Avoid routing the emitter/receiver cables in parallel with high-power motor lines or variable frequency drive (VFD) output cables. When configuring the Test Input on the emitter, wire it to an external control device to periodically verify system shut-off function as mandated by local safety standards.

Installation Guidelines

CRITICAL WARNING:

Ensure all primary electrical supply lines are locked and tagged out prior to physical installation. De-energize the entire cabinet and verify zero electrical potential. Failure to do so can result in permanent device damage, immediate optical array failure, or severe injury from unexpected machinery start-up.

1
Mechanical Alignment: Securely mount the emitter and receiver directly parallel to each other at the exact height required, ensuring both units sit completely plumb on their vertical axes.
2
Cable Connection: Connect the 4-pin M12 cables to both the emitter and receiver. Route cables using dedicated low-voltage conduit to avoid electromagnetic noise.
3
Optical Verification: Apply 24 VDC power and check the diagnostic LEDs on the receiver. Rotate the housings slightly to find the optimal optical sweet spot where the alignment indicators glow solid green.
Loading product navigation…

Can the F3SJ-E0465N25 be cascaded for multi-segment guarding?

No, the F3SJ-E Easy Series does not support cascading. For multi-segment or serial connections, select the F3SJ-B (Basic) or F3SJ-A (Advanced) series.

What does the 'N25' suffix represent in the model code?

The 'N' denotes NPN solid-state safety outputs (sinking logic), and '25' indicates a 25 mm detection capability designed specifically for industrial hand protection.

How do I troubleshoot intermittent optical alignment dropouts?

Check structural rigidity to eliminate machine frame vibrations. Additionally, ensure there are no highly reflective metal surfaces within the optical path angle limit of the emitter and receiver.

Can this unit be wired to a PNP safety controller?

It cannot be wired directly to PNP inputs because of its NPN sinking output stage. An intermediate NPN-to-PNP safety interface relay module must be used.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...