1 de 1

NS5-SQ00B-V2 | Omron | Panneau d'affichage interactif

NS5-SQ00B-V2 | Omron | Panneau d'affichage interactif

Il ne reste que 3 article(s) en stock
  • Fabricant : Omron

  • N° de produit : NS5-SQ00B-V2

  • Pays d'origine :Japon

  • Type de produit : Panneau d'affichage interactif

  • Paiement : Virement bancaire, Western Union

  • Poids : 1000g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for industrial machine-level visualization, the Omron NS5-SQ00B-V2 serves as a high-reliability interactive human-machine interface (HMI) within modern automation architectures. This panel bridges the communication gap between operators and PLCs, providing responsive touch control and reliable diagnostic displays. Configured with an energy-efficient display system, it operates seamlessly under demanding factory conditions while maintaining a low thermal signature inside electrical control panels.

Key Features

  • Stable Input Power: Optimised for 24 VDC standard industrial distribution networks.
  • Low Power Footprint: Consumes a maximum of 15 W, reducing heat dissipation within sealed enclosures.
  • Long-Term Data Integrity: Integrated memory backup battery features a nominal 5-year service life.
  • Environmental Protection: Built to withstand standard operational wear in environments clear of corrosive gases.

Applications

  • Automated assembly and packaging machinery interfaces.
  • Local control stations in water treatment and material handling facilities.
  • Process visualization terminals in food processing and manufacturing environments.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number NS5-SQ00B-V2
Device Type Interactive Display Panel (HMI)
Rated Voltage 24 VDC
Power Consumption 15 W maximum
Operating Environment No corrosive gases
Memory Backup Battery Life 5 years
Net Weight 1.0 kg
Shipping Weight 8.0 kg (including protective packaging)

Empirical Engineering Insights

Alternative Models & Compatibility

The -V2 designation marks a hardware revision that expands screen transfer capabilities and improves direct communication driver support for newer CJ2 and NJ/NX controllers compared to legacy V1 or non-suffix NS5 hardware. Screen files developed in CX-Designer can be easily converted and downloaded, but ensure the target system's system program (firmware) is updated to the matching runtime version of the project.

Application Pitfalls & Engineering Notes

Sustained operation in environments exceeding 40 degC significantly shortens the lifespan of both the screen backlight and the internal backup battery. If mounting within airtight enclosures alongside heat-generating components like active variable speed drives, install supplementary panel cooling or fan systems to prevent localized thermal degradation.

Commissioning & Wiring Tips

When wiring serial communications, use high-quality, individually shielded twisted-pair cables for the RS-232C connections to prevent noise coupling. Avoid routing communication lines parallel to high-current motor leads or power supply distribution cables within the wire ducts to ensure reliable high-speed data transmission.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL SHOCK HAZARD

Isolate and lock out all incoming 24 VDC power sources before mounting, wiring, or replacing the backup battery on this unit. Verify the complete absence of voltage with a calibrated instrument before beginning manual tasks to prevent personal injury or hardware destruction.

1

Prepare a precise panel cutout matching the specified mounting dimensions for the 5.7-inch NS5 chassis.

2

Insert the HMI unit into the cutout, ensuring the integrated waterproof rubber sealing gasket is seated uniformly flat against the front surface of the panel.

3

Secure the panel in position using the provided mounting brackets, tightening them evenly to the specified torque to maintain environmental sealing ratings without warping the front bezel.

4

Connect the dedicated functional ground terminal on the rear of the device to a verified low-impedance facility grounding bar using a minimum 2.0 sq mm copper wire.

Loading product navigation…

What is the expected backup battery lifespan for this HMI and how is it replaced?

The integrated memory backup battery has a typical service life of 5 years when operated under standard conditions. It can be replaced from the rear compartment of the panel while the system is powered down, though a quick swap is recommended to prevent the loss of internal system settings.

Does the NS5-SQ00B-V2 support direct EtherNet/IP communications?

This model relies on serial RS-232C interfaces for its primary communication channels. To utilize Ethernet-based networking protocols, a compatible expansion network board or an external adapter must be integrated.

What software is required to program and transfer screens to this display panel?

The panel is programmed using CX-Designer, which is a core utility included within Omron's CX-One automation software suite. Screens can be transferred via a standard USB connection or the serial ports.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...