Incorporate high-performance multi-channel analog signal acquisition into your automation system with the Omron NX-AD4208 differential analog input unit. This module operates on the NX I/O Bus platform, providing eight high-density analog input channels optimized for standard 4 to 20 mA current loops. Engineered for high-speed synchronous control, the unit achieves a conversion time of 0.08 ms per unit, making it ideal for fast process monitoring and dynamic motion control synchronization when paired with NX-series Machine Automation Controllers.

Featuring an ultra-slim 12mm width, the NX-AD4208 maximizes control panel space. It utilizes a detachable push-in (Screwless Push-In Plus) terminal block system, simplifying wiring layouts and significantly reducing maintenance downtime. The differential input circuitry ensures excellent common-mode noise rejection and measurement stability in electrically harsh industrial environments.

Features

  • Eight differential analog input channels configured for 4 to 20 mA current signals.
  • High-speed synchronous I/O refreshing mode for precise, real-time system synchronization.
  • Rapid conversion rate of 0.08 ms per unit for dynamic process tracking.
  • Space-saving 12mm housing width allows high-density cabinet layouts.
  • Detachable Push-In Plus terminal block simplifies installation and maintenance.
  • IP20 touch-safe degree of protection.

Applications

  • Process instrumentation monitoring (flow, pressure, and temperature transmitters).
  • Water and wastewater treatment facility control systems.
  • Automated chemical dosing and batching operations.
  • Factory automation and high-speed packaging machinery.

Technical Specifications

Manufacturer Omron
Model/Part Number NX-AD4208
I/O System Bus NX I/O Bus
Number of Analog Inputs 8
Input Circuit Type Differential
Input Range 4 to 20 mA
Conversion Time 0.08 ms per unit
Signal Processing Synchronous refreshing / Free-run refreshing
Connection Type Push-in (Screwless Push-In Plus)
Detachable Connector Yes (1 detachable I/O connector)
Degree of Protection IP20
Dimensions (W x D x H) 12 mm x 71 mm x 100 mm
Weight 0.07 kg (70 g)

Connections and Interfaces

Terminal Connection Function
A1 to A8 Positive Analog Input Terminal (Current Input +) Channels 1 to 8
B1 to B8 Negative Analog Input Terminal (Current Input -) Channels 1 to 8

Installation Guidelines

  • Mounting: Install directly onto a standard 35mm DIN rail. Ensure the module is securely locked into place on the NX-series bus.
  • Wiring: Use shielded twisted-pair cables for all 4 to 20 mA current loop connections to minimize electromagnetic interference. Ground the shield at the control panel side only.
  • Ventilation: Maintain standard clearance above and below the module rack to allow natural convective cooling. Do not block the integrated ventilation slots.
  • Terminal Block Removal: To prevent damage, ensure system power is completely isolated before removing or inserting the detachable push-in terminal block.
Loading product navigation…

What is the conversion speed of the Omron NX-AD4208?

The NX-AD4208 features a fast conversion time of 0.08 ms per unit, making it suitable for high-speed synchronous signal logging.

What type of input signals does this analog module accept?

This module is designed exclusively for 4 to 20 mA linear current analog inputs across 8 differential channels.

Is the terminal block on the NX-AD4208 removable?

Yes, the module is equipped with a detachable screwless Push-In Plus terminal block, allowing for quick pre-wiring and easy replacement without disconnecting field wiring.

Does the NX-AD4208 support synchronous refreshing?

Yes, it supports synchronous I/O refreshing when paired with compatible NX-series bus couplers and machine automation controllers.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...