1 of 1

NX-OD5256-1 | Omron | Unité d'E/S numérique série NX

NX-OD5256-1 | Omron | Unité d'E/S numérique série NX

Il ne reste que 7 article(s) en stock
  • Fabricant : Omron

  • N° de produit : NX-OD5256-1

  • Pays d'origine :Japon

  • Type de produit : Unité E/S numérique série NX

  • Paiement : Virement bancaire, Western Union

  • Poids : 125g

  • Dimensions : 30 mm x 100 mm x 71 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for seamless integration within high-speed Sysmac automation platforms, the NX-OD5256-1 serves as a high-density digital output module featuring 16 transistor outputs. This unit enables precise control over field actuators by delivering reliable switching performance synchronized with the machine controller's execution cycle. Operating on a 24 VDC rated voltage, the module utilizes PNP (source) logic and features built-in load short-circuit protection to safeguard system electronics against field-side electrical faults.

The unit supports advanced synchronization capabilities, allowing for both Free-Run and Synchronous I/O refreshing. Field connections are secured via a rugged, detachable M3 screw terminal block, which facilitates easy installation and maintenance. Designed for mounting on a standard DIN rail, this module connects directly to NX-series Bus Couplers for EtherCAT or EtherNet/IP, making it highly compatible with modern distributed control architectures.

Features

  • Provides 16 digital output points in a compact form factor.
  • Utilizes PNP (source) output logic with a rated voltage of 24 VDC.
  • Features integrated load short-circuit protection for system safety.
  • Supports Synchronous I/O refreshing and Free-Run refreshing modes.
  • Equipped with a detachable M3 screw terminal block for reliable physical wiring.
  • Simplifies configuration and troubleshooting via Sysmac Studio software.

Applications

  • Packaging and labeling machinery control
  • Automated assembly and material handling systems
  • Water treatment and environmental control panels
  • Pneumatic and hydraulic valve manifold actuation
  • General factory automation and distributed I/O systems

Technical Specifications

Parameter Specification
Manufacturer Omron
Part Number/Model NX-OD5256-1
Series NX-series Digital I/O Unit
Output Type Transistor Output (PNP/Source)
Number of Outputs 16 points
Rated Voltage 24 VDC
Maximum Load Current 0.5 A per point
I/O Refreshing Method Free-Run refreshing, Synchronous I/O refreshing
Short-Circuit Protection Yes (Load short-circuit protection)
External Connection Terminals M3 screw terminal block
Dimensions (W x H x D) 30 mm x 100 mm x 71 mm
Weight 0.125 kg

Installation Guidelines

Ensure the following engineering practices are observed during the installation of the module:

  • Mounting: Mount the module securely onto a 35 mm DIN rail inside a protective industrial enclosure. Verify the DIN rail is properly grounded.
  • Wiring: Turn off all power supplies before connecting or disconnecting the M3 screw terminal block to prevent electrical shock or equipment damage.
  • Heat Dissipation: Maintain recommended clearances above and below the NX-series unit stack to ensure natural convection cooling. Do not block the ventilation holes.
  • Shielding and Noise: Route DC control lines separate from high-voltage AC power lines to minimize electromagnetic interference.

Compliance and Certifications

  • CE Mark
  • UL Listed (cULus)
Loading product navigation…

What is the output logic type of the Omron NX-OD5256-1?

The NX-OD5256-1 uses PNP (source) transistor output logic.

What kind of terminal connection does this module use?

The module is equipped with a detachable M3 screw terminal block for secure field wiring.

Does the NX-OD5256-1 support synchronous refreshing?

Yes, it supports both Free-Run refreshing and Synchronous I/O refreshing depending on the NX-series coupler and controller configuration.

What is the maximum output current rating per point?

The maximum load current is 0.5 A per output point.

Does this digital output unit include protection circuits?

Yes, the unit features built-in load short-circuit protection to protect the internal circuitry from fault currents.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...