1 of 1

V680-HS52-R | Omron | Antenne cylindrique série V680

V680-HS52-R | Omron | Antenne cylindrique série V680

Il ne reste que 5 article(s) en stock
  • Fabricant : Omron

  • N° de produit : V680-HS52-R

  • Pays d'origine :Japon

  • Type de produit : Antenne cylindrique série V680

  • Paiement : Virement bancaire, Western Union

  • Poids : 2000g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for seamless integration into industrial RFID tracking architectures, the Omron V680-HS52-R provides robust electromagnetic communication with compatible data carriers in harsh manufacturing environments. This cylindrical M22-mount RFID antenna features a robotics-grade flexible cable designed to withstand continuous bending forces, making it ideal for robotic arms, automated gantry systems, and articulating machinery. Its industrial-grade construction ensures reliable data transmission and read/write integrity even when subjected to high vibration, mechanical shocks, and industrial cutting oils.

Features

  • Robotics-Grade Cable: Outfitted with a high-flexibility cable that resists wear under dynamic mechanical stress.
  • Heavy Industrial Protection: Dust-tight and water-immersion resistant construction ensures performance in demanding spaces.
  • Oil-Resistant Enclosure: Engineered to withstand degradation when exposed to common industrial lubricants and cutting fluids.
  • Compact M22 Form Factor: Standard cylindrical threaded body allows simple installation and micro-positioning adjustments.
  • High Mechanical Resilience: Specially rated to absorb repeat high-impact shocks and sweeping variable-frequency vibration profiles.

Applications

  • Robotic tool changers and articulated assembly arms.
  • Automated workpiece routing on high-speed conveyor lines.
  • Machining centers and CNC equipment exposed to metalworking fluids.
  • Automated guided vehicle (AGV) positioning systems.

Technical Specifications

Manufacturer Omron
Model / SKU V680-HS52-R
Product Series V680 Series
Component Type Cylindrical RFID Antenna
Form Factor M22 x 65 mm cylindrical body
Cable Type Flexible robotics cable with nonwaterproof connector
Ambient Operating Temp. -10 degC to 60 degC (no icing)
Insulation Resistance 20 MOhm minimum (at 500 VDC) between cable terminals and case
Shock Resistance 500 m/s2 in X, Y, and Z axes (3 times each, 18 total)
Vibration Resistance 10 to 500 Hz, 1.5 mm double amplitude at 100 m/s2 acceleration (10 sweeps, 8 minutes each in X, Y, Z)
Degree of Protection IP67 (IEC 60529:2001); Oil resistance equivalent to IP67G (JIS C 0920:2003) on antenna portion
Net Weight 0.85 kg
Shipping Weight 2.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The V680-HS52-R is directly distinguished from the standard V680-HS52 by its flexible robotics-grade cabling. If you are retrofitting a static conveyor line where the cabling is secured inside static conduit, the standard non-R model may be deployed; however, for dynamic, moving, or pivoting axes, the "-R" suffix model is critical to prevent cable fatigue and internal copper strand fractures. It must be paired with compatible V680 Series RFID Controllers (such as the V680-CA5D01-V2 or V680-CH series).

Application Pitfalls & Engineering Notes

When flush-mounting this M22 cylindrical antenna, beware of metallic detuning. Surrounding metal acts as a parasitic load, reducing the transmission field density and shortening the effective read/write distance. If the antenna must be recessed into a steel frame or aluminum bracket, ensure you maintain the OEM-specified non-metallic clearance zone around the radiating head to avoid communication dropouts or read retries.

Commissioning & Wiring Tips

Note that while the antenna portion features robust IP67G oil-resistance rating, the connector end interface is non-waterproof. This connection joint must be housed inside an IP-rated junction box or control cabinet if deployed in environments subject to direct washdowns or cutting fluid mist. Always route the antenna's flexible signal cable away from high-power alternating current (AC) lines and variable frequency drive (VFD) output wires to prevent electromagnetic noise from degrading RF data packets.

Installation Guidelines

CRITICAL WARNING

Ensure the host V680 controller is fully de-energized before connecting or disconnecting the antenna. Hot-swapping the RF connector can cause internal electrical transients, which may permanently damage the transceiver head circuits or corrupt active data on the carrier tags.

1

Mount the M22 antenna body into its bracket, ensuring any metallic structures remain outside the designated metal-free boundary surrounding the front sensing face.

2

Lock the antenna body in position using the supplied mounting nuts, taking care not to exceed the maximum torque specification to prevent housing thread damage.

3

Route the high-flexibility cable along the dynamic axis of movement, ensuring the minimum bend radius is maintained at all points and avoiding sharp pinching points.

4

Secure the non-waterproof connector interface inside an enclosed terminal box before routing the controller link to protect it from ambient atmospheric moisture.

Loading product navigation…

What is the key difference between the V680-HS52-R and the standard V680-HS52?

The V680-HS52-R features a robotics-grade flexible cable designed to withstand repetitive bending and dynamic mechanical movements, whereas the standard model is intended for static mounting applications.

Is the entire V680-HS52-R assembly waterproof and oil-resistant?

The cylindrical antenna head is rated IP67 and offers oil resistance equivalent to IP67G. However, the electrical connector on the end of the cable is non-waterproof and must be housed in a protected enclosure.

How does mounting this antenna near metal affect its RFID reading performance?

Surrounding metal can detune the antenna's magnetic field, leading to decreased read/write range or communication failures. Always maintain the recommended non-metallic physical clearance zone around the antenna head.

What is the insulation resistance of this RFID antenna?

The antenna provides an insulation resistance of 20 MOhms minimum when tested at 500 VDC between the cable terminals and the outer protective case.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...