1 de 1

Module d'entrée/sortie analogique Modicon Quantum Schneider Electric 140AMM09000

Module d'entrée/sortie analogique Modicon Quantum Schneider Electric 140AMM09000

Il ne reste que 10 article(s) en stock
  • Fabricant : Schneider Electric

  • N° de produit : 140AMM09000

  • Pays d'origine :France

  • Type de produit : Module d'entrée/sortie analogique

  • Paiement : Virement bancaire, Western Union

  • Poids : 300g

  • Dimensions : 16,7 cm x 31,5 cm x 4,5 cm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

This input/output analog module is designed for the Modicon Quantum automation platform to provide high-precision analog signal interfacing within industrial control systems. The hardware integrates a single-pole low-pass filter providing a attenuation of -3 dB at 21 Hz (+/- 20%) on the input circuit to manage electrical noise and ensure signal integrity.

Configured with 6 channels in total, the unit provides 4 analog inputs and 2 analog outputs. It features an addressing requirement of 5 input words and 2 output words. The input channels accommodate both bipolar and unipolar ranges, including bipolar current (+/- 20 mA), bipolar voltage (+/- 10 V, +/- 5 V), unipolar current (0...20 mA), and configured offsets such as 4...20 mA and 1...5 V. The output circuits operate within a 4...20 mA range with an external loop voltage requirement. This combination allows reliable data acquisition and control tracking in continuous process fields.

Features

  • High-Density Modularity: Features a 6-channel architecture providing 4 independent inputs and 2 dedicated outputs within a standard module format.
  • Configurable Input Capabilities: Supports multiple signal configurations including unipolar current, unipolar offset current, bipolar current, unipolar voltage, and bipolar voltage profiles.
  • Robust Noise Suppression: Incorporates an integrated single-pole low-pass filter rated at -3 dB at 21 Hz (+/- 20%) on the input circuit paths.
  • High-Resolution Conversion: Delivers up to 16-bit resolution for voltage inputs, 15-bit for standard current inputs, and 12-bit resolution for the analog output loop.
  • Channel-to-Bus Isolation: Provides electrical isolation rated at 500 V AC or 750 V DC for 1 minute between independent channels, channels and bus, and between input/output blocks.
  • Comprehensive Diagnostic LEDs: Equipped with direct local signaling including a green bus active status indicator, a red external fault indicator, and 6 green/red status markers for per-channel status and faults.

Applications

  • Water and wastewater treatment monitoring
  • Chemical and petrochemical processing plants
  • Boiler control and steam management systems
  • Continuous speed and position tracking loops
  • Multi-channel data acquisition systems

Technical Specifications

Parameter Category Technical Specification Parameter Value / Details
Identification Manufacturer Schneider Electric
  Range of Product Modicon Quantum automation platform 
Input Channels Analogue Input Number
  Input Modularity 6 channels 
  Analogue Input Types & Resolution

Bipolar current: +/- 20 mA (15 bits DC)


 

Bipolar voltage: +/- 10 V (16 bits DC)


 

Bipolar voltage: +/- 5 V (15 bits DC)


 

Unipolar current: 0...20 mA (15 bits DC)


 

Unipolar offset current: 4...20 mA (14 bits DC)


 

Unipolar offset voltage: 1...5 V (14 bits DC)


 

Unipolar voltage: 0...10 V (16 bits DC)


 

Unipolar voltage: 0...5 V (15 bits DC) 

  Absolute Maximum Input +/- 25 mA current / +/- 50 V voltage 
  Input Impedance > 10 MOhm voltage / > 250 Ohm current 
  Common Mode Rejection > 80 dB 50/60 Hz input circuit 
  Update Time (Input) 320 ms input circuit 
Output Channels Analogue Output Number
  Analogue Output Range 4...20 mA 
  Analogue Output Resolution 12 bits 
  External Power Requirement 7...30 V DC output circuit 
  Loop Voltage Limits 0...60 V DC with external resistance output circuit 
  Voltage Drop 30 V DC 20 mA 
  Setting Time 900 µs to +/- 0.1% of the final value output circuit 
  Update Time (Output) 15 ms output circuit 
System Demands Addressing Requirement 5 input words / 2 output words 
  Bus Current Requirement 350 mA 
Accuracy & Drift Absolute Accuracy Error

+/-0.03% at 25 degC input circuit


 

+/-0.20% of full scale at 25 degC output circuit 

  Linearity

+/-0.05% of full scale max at 25 degC input circuit


 

+/-0.004% of full scale at 0...60 degC output circuit 

  Offset Drift +/-0.0014 % of full scale max/degC 0...60 degC input circuit 
  Gain Shift

+/- 0.002 of full scale max 0...60 degC input circuit


 

+/-0.007 %/degC of full scale max at 0...60 degC output circuit 

Isolation Channel Isolation 500 V AC for 1 minute / 750 V DC for 1 minute 
  Channel to Bus Isolation 500 V AC for 1 minute / 750 V DC for 1 minute 
  Input to Output Isolation 500 V for 1 minute / 750 V for 1 minute 
Mechanical Module Format Standard 
  Product Weight 0.3 kg 
Environmental Operating Altitude <= 5000 m 
  Relative Humidity 95% without condensation 
  Ambient Air Temp (Operation) 0...60 degC 
  Ambient Air Temp (Storage) -40...85 degC 

Connections/Interfaces

Indicator / Terminal Status Function
Bus Active LED (Green) Indicates active backplane bus communication is present 
External Fault LED (Red) Indicates an external fault condition has been detected 
Channel Active LEDs (6x Green) Individually indicates that the corresponding channel is turned on 
Channel Fault LEDs (6x Red) Individually indicates an active fault on the corresponding channel 

Installation Guidelines

  • Enclosure Placement: Mount the standard format module within a verified Modicon Quantum rack slot. Ensure proper retention screws are fastened to resist mechanical stress.
  • External Power Connection: Secure an external power supply ranging from 7...30 V DC to drive the analog output circuit loops effectively.
  • Signal Shielding: Use twisted-pair shielded cables for analog signal line routing. Ground the shields according to standard engineering practices to optimize common mode rejection.
  • Environmental Thresholds: Ensure ambient air temperatures remain between 0 and 60 degC during active system operation, with relative humidity held below 95% without condensation.

Compliance and Certifications

  • Standards: CSA C22.2 No 142, UL 508 
  • Product Certifications: CE, C-Tick.1, FM Class 1 Division 2 
  • Electromagnetic Field Resistance: 10 V/m 80...2000 MHz conforming to IEC 801-3 
  • Sustainability & Directives: Green Premium product, RoHS compliant (since date code 0842 Schneider Electric declaration of conformity), REACH reference not containing SVHC above the designated threshold 

FAQ

  • What specific fault types can the diagnostic circuit paths register?

    The module detects an open circuit condition on both the input and output lines, an overtracking scale error on unipolar input loops, and updates the dedicated status byte for output parameters.

  • What is the purpose of the built-in filtering circuit on this hardware?

    Each input incorporates a single-pole low-pass filter providing an attenuation of -3 dB at 21 Hz (+/- 20%) to damp high-frequency electrical noise before signal processing.

  • Does the analog output section draw its operating voltage directly from the backplane bus?

    No. While the module requires 350 mA from the backplane bus for internal processing, the analog output loop requires an independent external power connection supplying 7...30 V DC.

  • What are the isolation parameters between the input and output sides of the module?

    The internal dielectric boundaries provide continuous isolation rated up to 500 V AC or 750 V DC for 1 minute between the input channels and output channels.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.
Download Now

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Blanc grisâtre
Country of origin
France
Power source
Alimentation DC

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...