1 / 1

Beckhoff CX8010 Embedded PC with EtherCAT Slave

Beckhoff CX8010 Embedded PC with EtherCAT Slave

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: CX8010

  • Country of origin:Németország

  • Product Type: Embedded PCs

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 64 mm x 100 mm x 73 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Directing decentralized execution tasks within real-time automation topologies is the primary function of the Beckhoff CX8010. This compact, DIN-rail-mounted control unit integrates an ARM9 400 MHz processor with a specialized EtherCAT slave interface, permitting seamless integration as a high-performance decentralized node under a primary EtherCAT master. Operating on the Windows Embedded CE 6 operating system, the controller uses the TwinCAT 2 PLC software environment to execute deterministic control loops, processing local logic while maintaining cyclic communication over its physical interfaces. Built-in, automatic terminal detection accommodates either E-bus or K-bus I/O architectures, allowing engineers to scale localized signal acquisition without external adapter hardware.

Key Features

  • Dual Bus Support: Automatic sensing and management of Beckhoff E-bus (EtherCAT) and K-bus (standard bus terminal) components.
  • Integrated UPS: Capable of supplying power for 1 second to write up to 1 MB of persistent data to the non-volatile storage during a voltage sag.
  • Deterministic Processing: ARM9 core design running at 400 MHz optimized for low-overhead PLC logic execution under IEC 61131-3 standards.
  • Flexible Storage Options: External microSD slot supporting memory expansion beyond the default 512 MB configuration.
  • Comprehensive Ex Ratings: Engineered for hazardous locations with ATEX, IECEx, and cFMus Class I Division 2 certification.

Applications

  • Decentralized Processing Nodes: Distributed control architectures where independent, local decisions must be synchronized with a centralized master controller.
  • Substation Protocol Conversion: Bridging operational localized I/O nodes with high-level plant monitoring via the integrated 10/100 Mbit/s Ethernet port.
  • OEM Modular Machinery: Packaging, assembly, and conveyor subsystems requiring dedicated local computing, small physical footprints, and direct DIN-rail installation.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff Automation
Model Number CX8010
Processor ARM9, 400 MHz, 1 Core
Flash Memory 512 MB microSD (expandable)
Main Memory 64 MB DDR2 RAM (non-expandable)
Persistent Memory 1-second UPS (retains 1 MB persistent data)
Operating System Windows Embedded CE 6
Control Software TwinCAT 2 PLC runtime
Fieldbus Interface EtherCAT IN & OUT (2 x RJ45)
Local I/O Capacity E-bus or K-bus automatic detection (up to 2 A power supply)
Maximum Power Consumption 3 W
Dimensions (W x H x D) 64 mm x 100 mm x 73 mm
Environmental Temperature Operating: 0 to 55 degC | Storage: -25 to 85 degC
Relative Humidity 95% non-condensing
Protection Rating IP20
Ex Markings ATEX II 3 G Ex nA IIC T4 Gc / IECEx Ex nA IIC T4 Gc / cFMus Cl. I Div. 2
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Port / Physical Interface Technical Assignment & Function
1 x RJ45 (Ethernet) 10/100 Mbit/s Network link for system programming, visualization, and host connectivity.
2 x RJ45 (EtherCAT) Dedicated EtherCAT IN and OUT ports configured to act as an EtherCAT slave interface.
1 x USB Device Service-only USB connection positioned securely behind the front access panel.
I/O Bus Contact Slide Mechanical logic interface feeding power and data channels to connected E-bus or K-bus terminals.

Alternative Models & Compatibility

The CX8010 is specifically tailored as an EtherCAT slave. If your system design requires protocol mastership or communication over alternative industrial standards, consider the CX8090 (Ethernet/IP / Modbus TCP) or the CX8031 (PROFIBUS slave). Due to the hardware architecture running Windows CE 6, the CX8010 is not compatible with TwinCAT 3 runtime projects. Existing TwinCAT 2 software platforms must be utilized for compilation and program download.

Application Pitfalls & Engineering Notes

Ensure that the total power demand of the attached slice terminals does not exceed the 2 A current supply limit of the internal E-bus/K-bus power contacts. When designing dense terminal assemblies, utilize specialized power supply terminals (such as the EL9410) to inject additional current. The 1-second persistent data UPS is capacitive-based and relies on an internal charge cycle. If consecutive power loss cycles occur within rapid succession, the capacitor will not have recharged sufficiently to complete a secure write operation to the microSD card.

Commissioning & Wiring Tips

To maintain signal integrity on the EtherCAT line, use shielded Cat5e SF/UTP cables grounded directly at the panel penetrations. Ensure that the DIN rail has a direct, low-resistance ground path. At initial power-up, the CX8010 scans the physical Bus Terminal backplane. Do not mix K-bus and E-bus terminals within the same mechanical group, as the system will fault during the auto-detection phase. Always ensure the front protective flap is fully closed during operational runs to maintain the IP20 environmental rating and prevent contamination of the battery compartment.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical power sources prior to mounting, disassembling, or wiring the controller. Failure to disconnect high-voltage systems can lead to structural damage to the CPU logic cards, terminal failure, or electrical shock. Confirm that all local safety standards are respected before energizing the device.

1

Mount the CX8010 vertically on standard 35 mm DIN rail (EN 60715) with the release tab pointing downward.

2

Slide local I/O terminals (E-bus or K-bus) onto the right-hand connection point until the mechanical lock clicks home.

3

Connect the 24V DC auxiliary power supply to the terminals on the integrated power supply module.

4

Connect network cables to the EtherCAT slave ports (IN/OUT) and complete initialization via TwinCAT System Manager.

Can the CX8010 be configured to run TwinCAT 3 software?

No. The CX8010 is equipped with an ARM9 processor running Windows Embedded CE 6, which restricts its runtime configuration exclusively to the TwinCAT 2 programming environment.

How does the system distinguish between E-bus and K-bus terminals?

The CX8010 features an automatic physical bus detection sequence at startup. It queries the electronic data of the connected backplane to configure the corresponding bus control loop.

How is persistent variables data saved on sudden power failure?

The unit integrates a capacitive-based 1-second UPS. On loss of primary power, this storage holds sufficient energy to write up to 1 MB of persistent data to the non-volatile memory.

Does the CX8010 support fieldbus master operation?

No. The CX8010 is specifically configured as an EtherCAT slave interface unit. If master functionality is required, other models in the CX series must be used.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Németország

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...