Product Overview

The Beckhoff EK1101 (EK1101) is a high-performance EtherCAT coupler designed to bridge 100BASE-TX Ethernet networks with the modular Beckhoff EL-series terminal system. As a critical interface for industrial automation, the EK1101 facilitates seamless communication, enabling the connection of up to 65,534 EtherCAT terminals in a single distributed I/O framework. Featuring an integrated ID switch for identity verification, this coupler ensures precision in machine configuration and diagnostic mapping, making it an essential component for complex, high-speed automated production environments.

Technical Configuration

The EK1101 is engineered for industrial-grade data transfer at 100 Mbit/s, utilizing standard shielded Cat.5 Ethernet cabling. It provides robust electrical isolation (500 V) between the power supply, E-bus, and Ethernet interface, which is vital for preventing ground loop issues in expansive fieldbus architectures. The coupler delivers a 2000 mA E-bus current supply to downstream terminals and supports a load-sharing power contact rating of 24 V DC / 10 A. The compact, IP20-rated polycarbonate housing includes diagnostic signal LEDs, allowing maintenance teams to quickly assess network status and identify connectivity faults without specialized diagnostic software.

Technical Specifications

Feature Specification
Model EK1101
Protocol EtherCAT
Bus Interface 2 x RJ45
Data Rate 100 Mbit/s
I/O Capacity Up to 65,534 Terminals
Power Supply 24 V DC
E-bus Current 2000 mA
Ambient Temp. -25 to +60 deg C
Dimensions 44 mm x 100 mm x 68 mm
Net Weight 0.105 kg

FAQs

What is the purpose of the integrated ID switch?

The ID switch allows you to assign a unique identifier to the coupler. This feature is particularly useful in modular machines where multiple identical I/O stations are used, as it enables the EtherCAT master to verify identity and ensure the correct I/O station is being addressed, even if the cable sequence is changed.

Can I daisy-chain this coupler?

Yes, the EK1101 includes two RJ45 ports, allowing it to function as a drop-in node in an EtherCAT line topology. The second port facilitates the connection of additional EtherCAT devices or segments downstream.

Is this coupler suitable for use in hazardous areas?

Yes, the EK1101 holds multiple hazardous location certifications, including ATEX (II 3 G Ex nA IIC T4 Gc) and IECEx/cFMus Class I, Division 2, making it suitable for deployment in Zones 2 or Division 2 environments when installed in a proper enclosure.

How does the 1 µs delay affect system performance?

The minimal delay of approximately 1 µs is negligible, ensuring that the EK1101 maintains the sub-millisecond, real-time performance expected from EtherCAT systems, even when dozens of couplers are cascaded in a large machine network.

Installation Guidelines and Best Practices

  • Ethernet Cabling: Always use shielded Cat.5 or higher cabling. Ensure that the shield is properly terminated to ground at the cabinet entry to maintain the integrity of the 100 Mbit/s data stream and fulfill EMC emission standards (EN 61000-6-4).
  • Power Distribution: When calculating your power budget, remember the EK1101 current consumption: 70 mA + (total E-bus current / 4). If your terminal count exceeds the 2000 mA E-bus capacity, you must insert an EL9410 power supply terminal to refresh the E-bus voltage.
  • Wiring Technique: The coupler supports spring-actuated terminals for solid and stranded conductors (up to 2.5 mm²). Ensure a stripping length of 8–9 mm for all wires to provide secure, vibration-resistant contact.
  • Mounting: Use the integrated double slot and key connection for side-by-side mounting. Always lock the terminal onto the 35 mm DIN rail (EN 60715) to maintain contact integrity in high-vibration applications.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Fehér
Country of origin
Németország

Nemrég megtekintett termékek

Műszaki ismeretek

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...