Engineered for resilient deployment in rugged industrial environments, the Delta Electronics DVS-110W02-3SFP serves as a robust communications backbone featuring 7 Fast Ethernet ports and 3 Gigabit Ethernet combo ports. This managed switch optimizes critical industrial control loops by offering redundant dual-rate SFP slots alongside copper physical media, ensuring flexible fiber trunking across long distances. Encased in a rugged IP40 metal chassis, this device operates reliably across a wide temperature spectrum from -40 degC to 75 degC, matching the strict requirements of substation, wind power, and intelligent traffic management systems.

Key Features

  • Flexible Port Density: Incorporates 7 x 10/100Base-T(X) RJ45 copper ports and 3 x 10/100/1000Base-T / 100/1000Base-SFP combo ports.
  • Hardened Diagnostics: Dual digital inputs and dual relay outputs for immediate, on-site alarm notifications and system state integration.
  • Redundancy Mechanics: Supports redundant dual power inputs to preserve network status during primary source failures.
  • Industrial-Grade Enclosure: Heavy-duty IP40 metal housing provides superior heat dissipation and high electromagnetic immunity.
  • Advanced Management: Enables comprehensive ring redundancy, VLAN configuration, QoS priorities, and secure SNMP capabilities.

Applications

  • Substation automation and renewable energy SCADA collection nodes.
  • Traffic control cabinet systems requiring high operating temperature tolerances.
  • Water and wastewater plant networking utilizing distributed redundant PLC networks.
  • Factory floor automation with mixed copper-to-fiber industrial Ethernet networks.

Technical Specifications

Parameter Value
Manufacturer Delta Electronics
Model Number DVS-110W02-3SFP
Series DVS-110 Series
Copper RJ45 Ports 7 x 10/100Base-T(X), Auto MDI/MDI-X
Combo Ports 3 x 10/100/1000Base-T or 100/1000Base-SFP active dual-rate
Digital Inputs (DI) 2 x Dry Contact inputs (max state detection)
Digital Outputs (DO) 2 x Relay outputs (rated 1 A at 24 VDC)
Input Voltage Range Dual redundant 12 to 48 VDC terminal block inputs
Enclosure Protection IP40 metal case
Operating Temperature -40 degC to 75 degC
Storage Temperature -40 degC to 85 degC
Mounting Options DIN-rail mounting standard, optional wall mount
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Terminal / Port Block Interface Assignment
Ports 1 to 7 10/100Base-T(X) RJ45 pins for local field devices
Ports 8 to 10 (Combo) Dual-purpose copper/fiber ports for Gigabit uplinks
Terminal Block (V1+, V1-) DC Primary Power Input (12 to 48 VDC)
Terminal Block (V2+, V2-) DC Backup/Redundant Power Input (12 to 48 VDC)
Terminal Block (DI1, DI2, DI COM) Digital Inputs for remote dry-contact sensor monitoring
Terminal Block (R1, R2) Relay contact outputs for automated trip/fault alerting

Empirical Engineering Insights

Alternative Models & Compatibility

The DVS-110W02-3SFP represents the premium high-availability model in the DVS-110 series. Unlike the non-SFP models (e.g., DVS-110W02), which rely solely on RJ45 copper uplinks, this variant supports mixed-mode topologies. If substituting for older series switches, ensure that the active SFP transceivers match the optical wavelength and distance limits of existing transceivers, as modern Delta firmware strictly monitors DDMI parameters and may report SFP diagnostic faults if mismatched or low-quality components are installed.

Application Pitfalls & Engineering Notes

While the DVS-110W02-3SFP switch functions perfectly up to 75 degC, operating near this limit inside unventilated, high-voltage control panels can accelerate the aging of internal electrolytic capacitors. To avoid localized thermal pockets, maintain at least 50 mm of vertical clearance above and below the switch chassis. Furthermore, standard-grade SFP transceivers can overheat and fail if run in environments exceeding 60 degC; always verify that installed transceivers are rated for extended industrial operating ranges.

Commissioning & Wiring Tips

To prevent operational ground loops, ground the switch's chassis directly to the field cabinet ground plate using a heavy gauge copper conductor connected to the protective earth screw on the switch's top block. Additionally, configure the SNMP alert thresholds within the switch's management utility during initial commissioning to capture dry-contact digital input changes, allowing immediate detection of physical cabinet door breaches or localized surge protection device (SPD) trips.

Installation Guidelines

CRITICAL WARNING

Verify that all incoming DC power lines are completely de-energized and locked out before wiring the terminal block connectors. Failure to isolate power can result in transient electric arcing, causing equipment damage or personal injury. Ensure the protective earth terminal is fully connected prior to completing any interface or power connection.

1
Mount the DVS-110W02-3SFP onto a standard 35 mm symmetric DIN rail, securing it with the rear-integrated spring-locked mounting bracket.
2
Connect the functional/protective earth terminal from the top of the switch body directly to the cabinet ground bar using a low-impedance copper wire.
3
Insert the stripped power conductors into the terminal block plug, secure the screw terminals, and plug the block into the switch (V1 and V2 for redundant topologies).
4
Insert necessary RJ45 copper cables and matching SFP transceivers, confirming positive click-locking for all physical media links.

Does the DVS-110W02-3SFP support both single-mode and multi-mode SFP transceivers?

Yes. The three SFP slots support both single-mode and multi-mode SFP fiber transceivers operating at 100 Mbps or 1000 Mbps line speeds.

What happens if one of the dual DC power inputs fails?

The switch switches transparently to the secondary power input without packet loss, and can trigger the integrated alarm relay to warn operators of the power drop.

Can the digital inputs on this switch monitor dry contacts?

Yes, the two integrated digital inputs are designed for dry contact connection to easily integrate enclosure door switches or alarm sensors.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...