1 / 1

Mitsubishi Electric FR-A740-1.5K-CHT FR-A700 Series Inverter

Mitsubishi Electric FR-A740-1.5K-CHT FR-A700 Series Inverter

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-A740-1.5K-CHT

  • Country of origin:Egyesült Államok

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 5000g

  • Dimensions: 270 x 190 x 180 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Engineered to deliver high-performance motor control in demanding industrial environments, the Mitsubishi Electric FR-A740-1.5K-CHT variable frequency drive operates as a robust 3-phase speed and torque controller. Incorporating advanced vector control algorithms, this drive ensures exceptional dynamic response and steady-state speed accuracy for induction motors. The FR-A740-1.5K-CHT is built to withstand rigorous operating conditions, featuring integrated safety functions, a built-in programming terminal, and regional optimization parameters that streamline integration within standard automation systems.

Features

  • Real-Time Sensorless Vector Control: Achieves high torque at ultra-low operating speeds without requiring an encoder feedback loop.
  • Built-in PLC Functionality: Allows users to program custom control logic and sequence operations directly within the drive, reducing external controller hardware dependencies.
  • Optimized Thermal Performance: Equipped with dual internal cooling fans and premium varnished circuit boards to resist dust, humidity, and corrosive atmosphere.
  • Energy-Saving Optimization: Implements adaptive flux control to minimize motor excitation currents under partial load states, reducing energy consumption.

Applications

  • Heavy-duty conveyor lines and bulk material handling systems.
  • Industrial fan, blower, and centripetal pump flow regulation.
  • Machine tool spindles, high-speed mixers, and extruders requiring stable torque limits.
  • Automated packaging machinery and process control systems.

Technical Specifications Table

Parameter Value / Specification
Manufacturer Mitsubishi Electric
Model Number FR-A740-1.5K-CHT
Inverter Series FR-A700 Series
Applicable Motor Capacity 1.5 kW
Rated Output Current 4.0 A
Rated Output Voltage 3-phase, 380 to 480 V AC
Input Voltage Class Three-phase 400V class
Permissible AC Voltage Fluctuation 325 to 528 V AC (50Hz / 60Hz)
Overload Capacity 150% for 60 seconds, 200% for 3 seconds (at 50 degC)
Enclosure Rating IP20 (Open Type)
Cooling System Forced Air Cooling
Control Circuit Terminal Screws M3 x 35 mm
Shipping Weight (Calculated) 5.0 kg
Package Dimensions (Calculated) 270 x 190 x 180 mm

Connections and Interfaces

Terminal Marker Function Description
R/L1, S/L2, T/L3 Main 3-phase AC power input
U, V, W 3-phase AC motor output connections
P/+, PR Brake resistor external connection terminals
STF, STR Forward and Reverse start signal inputs
SD Common terminal for contact input signals
10, 2, 5 Analog input terminals for voltage speed setting

Alternative Models & Compatibility

The "CHT" designation identifies models specifically optimized for Asian market profiles. It offers full physical and functional interchangeability with standard EU/US versions like the FR-A740-1.5K-NA. When migrating from older FR-A540 series systems, ensure parameter adaptations are executed to align with the higher resolution of the FR-A740 control loop.

Application Pitfalls & Engineering Notes

In low-speed operations under heavy loads (less than 20 Hz), standard self-cooled motors cannot dissipate heat efficiently. For continuous low-speed operations, configure thermal motor protection parameter Pr. 9 for a constant-torque motor or deploy an auxiliary blower. Keep enclosure internal temperatures below 50 Celsius to prevent premature thermal derating of the internal DC bus capacitor banks.

Commissioning & Wiring Tips

To eliminate stray capacitive leakage currents in installations with cable runs exceeding 30 meters, reduce the carrier frequency using parameter Pr. 72. Ground the inverter separately using a dedicated grounding line with a resistance of 10 ohms or less, and run signal wires separate from the main power lines by at least 10 cm to prevent electrical noise coupling.

Installation Guidelines

CRITICAL WARNING: Ensure all incoming AC lines are fully de-energized prior to terminal access. Wait a minimum of 10 minutes after disconnecting power to allow internal bus capacitors to bleed residual charge. Verify that the internal red charge lamp is completely extinguished, and test DC bus terminals P/+ to N/- with a verified voltmeter to ensure voltage is under 30 V DC before commencing work.
1

Mount the inverter vertically against a non-combustible steel panel to allow optimal convection airflow over the rear heatsinks.

2

Connect ground lines to the PE terminal before establishing main line power routing to U, V, and W output stages.

3

Torque all power terminal block connections securely to the specified OEM torque limits to mitigate high-resistance thermal junctions.

What is the primary function of the CHT suffix on the FR-A740-1.5K-CHT?

The CHT suffix designates that the variable frequency drive is configured for regional Asian markets. It features identical internal performance hardware to global versions but defaults to sink (NPN) control logic configurations.

Can this drive run on a single-phase 400V input supply?

No. The FR-A740-1.5K-CHT requires a standard three-phase AC input supply ranging from 380V to 480V. Operating on single-phase supply lines will trip the input phase-failure protection (E.ILF).

How do I resolve an E.THT fault on the FR-A740-1.5K-CHT?

An E.THT fault indicates inverter overload. Verify the motor current draw matches parameters, check for mechanical blockages, confirm the cooling fans are spinning freely, and check that parameter Pr. 9 is set to match the motor's rated current.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...