Mitsubishi Electric FR-A740-15K FR-A700 Variable Frequency Drive

Mitsubishi Electric FR-A740-15K FR-A700 Variable Frequency Drive

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-A740-15K

  • Country of origin:Egyesült Államok

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 7500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Providing high-performance vector control for heavy-duty industrial applications, the Mitsubishi Electric FR-A740-15K frequency inverter delivers precise motor regulation across demanding operational profiles. This variable frequency drive (VFD) from the FR-A700 Series is engineered for complex systems requiring high torque, exceptional speed accuracy, and advanced motor control dynamics. Operating on a 400V class three-phase input, it handles a nominal motor output of 15 kW, making it a reliable component in heavy machinery, extrusion lines, cranes, and continuous manufacturing systems.

Equipped with Real Sensorless Vector (RSV) control and advanced vector control algorithms, the drive achieves outstanding speed and torque performance without requiring encoder feedback. The integrated PLC functionality allows users to customize control sequences directly within the inverter, reducing external hardware overhead and simplifying system integration.

Features

  • Real Sensorless Vector Control: Achieves high torque at ultra-low speeds (200% at 0.3 Hz) for high-inertia start-up profiles.
  • Optimum Excitation Control: Automatically adjusts the excitation current to maximize motor efficiency, reducing energy consumption under partial loads.
  • Built-in PLC Programming: Enables customized logic and automated control loops via Mitsubishi's software environment, bypassing the need for an external micro-PLC.
  • Advanced Torque Limiters: Protects mechanical drivetrains with fast, highly responsive 4-quadrant torque limitation.
  • USB Port Integration: Front-mounted interface for swift configuration, diagnostics, and parameter backup using FR Configurator software.

Applications

  • Hoists and Cranes: High-starting torque and mechanical brake control linkage ensure safe and smooth vertical transitions.
  • Extruders and Mixers: Provides stable speed regulation under fluctuating viscosity loads.
  • Centrifuges and Fans: Energy-efficient operation through optimized excitation and smooth deceleration control.
  • Conveyor Networks: Precise multi-drive speed synchronization prevents physical product damage and belt wear.

Technical Specifications

Parameter Value / Specification
Manufacturer Mitsubishi Electric
Model Number FR-A740-15K
Inverter Series FR-A700
Voltage Class 400V Class (Three-Phase 380 to 480 VAC, 50/60 Hz)
Permissible AC Voltage Fluctuation 323 to 528 VAC (50Hz/60Hz)
Applicable Motor Capacity 15 kW
Rated Output Current 31 A
Overload Current Rating 150% 60 seconds, 200% 3 seconds (at ambient temperature of 50 degC)
Cooling Method Forced Air Cooling
Enclosure Rating IP20 (Open Type)
Net Weight 7.5 kg
Shipping Weight (Calculated) 9.0 kg

Connections and Interfaces

Terminal Group Functional Assignment
R/L1, S/L2, T/L3 Main 3-phase AC power supply input terminals.
U, V, W 3-phase AC output connections to the induction motor.
P/+, PR Connection terminal for optional external brake resistor.
STF / STR Forward rotation start / Reverse rotation start control terminals.
10, 2, 5 Analog input terminals (0 to 10 VDC, 4 to 20 mA) for external frequency references.

Empirical Engineering Insights

Alternative Models & Compatibility

When migrating or sourcing drop-in replacements, note that the FR-A740-15K shares functional equivalents within the newer FR-A840-00380-E2-60 (A800 series). Parameter transfer from the A700 to the A800 series can be automated via the FR Configurator2 software. However, verify terminal assignment modifications, as the control terminal blocks differ in wiring entry formats (screw terminals on the A700 vs. spring clamp terminals on the A800).

Application Pitfalls & Engineering Notes

If operating in high ambient conditions (above 40 degC), the carrier frequency should be adjusted downward (Parameter 72) to prevent premature thermal overcurrent faults (E.THT). Avoid continuous operation below 6 Hz without supplementary external motor cooling fan kits, as standard self-cooled motors will experience severe thermal degradation at reduced speeds due to diminished internal fan velocity.

Commissioning & Wiring Tips

Always ensure that Parameter 9 (Electronic Thermal O/L Relay) is set to match the nameplate current of the connected motor; the factory default corresponds to the maximum rating of the VFD and may fail to protect smaller motors. Install control signals using shielded twisted-pair cables with the shield grounded only at the drive end (Terminal 5) to mitigate electromagnetic interference in analog circuits.

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE HAZARD

Isolate all input AC power before performing any terminal modifications or inspection routines. Wait a minimum of 10 minutes after physical power disconnection for the internal DC-bus capacitors to fully discharge. Verify that the DC-bus voltage between terminals P/+ and N/- is below 45 VDC using a calibrated digital multimeter before proceeding with touch operations.

1

Mount the inverter vertically inside an IP54 enclosure if the environment is dusty or humid, ensuring a minimum clearance of 10 cm above and below the unit for unobstructed heat dissipation.

2

Ensure the physical ground connection meets standard industrial safety requirements (Earth resistance under 10 ohms). Use a thick copper protective conductor connected to the drive's PE terminal.

3

Confirm that power cable routing is physically separated from control and encoder feedback signaling paths to minimize capacitive coupling noise.

Can I run a standard induction motor at high torque at low speeds using the FR-A740-15K?

Yes. When set to Real Sensorless Vector (RSV) control, this VFD can deliver up to 200% starting torque at 0.3 Hz. Ensure that you run the offline auto-tuning function with the motor uncoupled to map the motor winding characteristics accurately.

What is the proper procedure if the E.THT fault occurs frequently?

The E.THT fault indicates motor thermal overload. Verify that Parameter 9 matches your motor's rated current. If the load requires low-speed operation under heavy load, consider installing an external forced cooling fan on the motor or lower the carrier frequency (Parameter 72) on the drive.

Does this drive require an external braking resistor for high-inertia stops?

Yes, for applications with rapid deceleration cycles or highly regenerative loads (such as cranes or high-inertia fans), you must connect an external brake resistor across terminals P/+ and PR. Ensure the braking duty cycle parameters are updated in the drive config.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...