1 / 1

FR-F840-00380-2-60 Mitsubishi Electric FR-F800 Series Variable Frequency Drive

FR-F840-00380-2-60 Mitsubishi Electric FR-F800 Series Variable Frequency Drive

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-F840-00380-2-60

  • Country of origin:Egyesült Államok

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Engineered for heavy-duty fan and pump speed control, the Mitsubishi Electric FR-F840-00380-2-60 is an industrial variable frequency drive (VFD) from the premium FR-F800 Series. Operating within the 400V three-phase class, this inverter delivers a Light Duty (LD) capacity of 18.5 kW. This specific unit features the robust -60 specification, signifying that internal circuit boards are treated with a specialized protective conformal coating and include plated conductors. This added layer of defense prevents degradation in corrosive, humid, or dusty environments, ensuring maximum operational uptime in wastewater treatment facilities, commercial HVAC units, and industrial plant automation panels.

Key Features

  • Environmental Optimization (-60 Spec): Coated circuit boards and plated conductors resist airborne particulate contamination and corrosive gases.
  • Energy-Saving Excitation Control: Constantly calculates optimal magnetic flux to maximize motor efficiency and reduce active power consumption.
  • Dual-Rating Load Capacity: Supports both Light Duty (LD) and Super Light Duty (SLD) parameter settings for optimal matching to variable torque loads.
  • Integrated Safety Architecture: Complies with functional safety regulations for emergency shutdown capability without external contactors.

Applications

  • Industrial exhaust fans, ventilation hoods, and commercial HVAC blowers.
  • Centrifugal booster pumps and municipal water supply systems.
  • Cooling tower fans and air compressor control systems.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Number FR-F840-00380-2-60
Inverter Series FR-F800 Series
Voltage Class 400V Class (Three-Phase Input)
Inverter Capacity (LD) 18.5 kW
Structure Variant Standard Model
Type Code -2 (CA Variant)
Environmental Protection Conformal Board Coating and Plated Conductor (-60 Spec)
Net Weight 8.3 kg
Shipping Weight (Calculated) 10.0 kg

Connections and Interfaces

Terminal Designation Functional Assignment
R/L1, S/L2, T/L3 Three-phase AC power input (400V class)
U, V, W Three-phase AC output connections to the induction motor
P/+, PR Connections for optional external brake resistor configurations
Control Terminals Standard analog voltage/current inputs, digital inputs, and fault relay outputs

Empirical Engineering Insights

Alternative Models & Compatibility

When migrating legacy systems from the older FR-F740 series, parameter mappings can be transferred using FR Configurator2 software. However, please note that physical dimensions and wiring terminal layouts differ slightly. Ensure that panel backplate drill patterns are verified before mechanical mounting.

Application Pitfalls & Engineering Notes

The FR-F840-00380-2-60 is rated primarily for Light Duty (LD) application profiles (variable torque loads). If applying this drive to constant torque loads, such as heavy positive displacement pumps or conveyor drives, you must derate the continuous current output or transition to the FR-A840 series to prevent overcurrent trip events (E.OC1 to E.OC3) during startup acceleration.

Commissioning & Wiring Tips

Ensure that the built-in EMC filter is configured correctly for your local earthing system. When installing this unit on an IT (ungrounded) network or an asymmetric earthed system, disconnect the internal EMC filter grounding jumper to prevent high-frequency leakage currents from tripping upstream ground fault protective devices.

Installation Guidelines

CRITICAL WARNING: Hazardous voltages remain present on the internal DC bus capacitors even after the mains power is disconnected. De-energize all primary input lines and wait a minimum of 10 minutes. Use a reliable digital multimeter to measure and verify zero voltage across terminals P/+ and N/- before accessing the wiring terminals or executing service actions.
1
Mount the inverter vertically on a flat, non-flammable surface to maintain optimal heat sink thermal dissipation. Keep a minimum clearance of 50mm on both sides and 100mm above/below the unit.
2
Connect a dedicated high-integrity system ground to the earth terminals. Avoid daisy-chaining ground wiring between adjacent variable frequency drives to suppress common-mode high-frequency noise.
3
Ensure all power and control signal cables are strictly segregated. Use separate metal conduit runs for power lines and shielded control cables to prevent inductive electromagnetic coupling.

What is the benefit of the -60 suffix on the FR-F840-00380-2-60?

The -60 suffix indicates that the internal printed circuit boards are treated with a protective conformal coating and have plated conductors, safeguarding the electronics against moisture, dust, and corrosive gas environments.

Can this drive be used with constant torque applications like cranes or heavy conveyors?

No, this model is designed with a Light Duty (LD) rating optimized for variable torque applications such as fans and centrifugal pumps. Constant torque loads require high starting torque and should be paired with the FR-A800 series.

How long must I wait to access the internal terminals after cutting the power?

You must wait at least 10 minutes to allow the DC bus capacitors to discharge fully, and then verify that there is zero voltage across terminals P/+ and N/- using a multimeter.

Does this drive include a built-in EMC filter?

Yes, it contains an integrated EMC filter. If you are operating the drive on an IT or asymmetric earthed grid, the filter ground connector should be disconnected to avoid leakage current trips.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...