Mitsubishi Electric FR-A740-2.2K-CHT FR-A700 Series Variable Frequency Drive

Mitsubishi Electric FR-A740-2.2K-CHT FR-A700 Series Variable Frequency Drive

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-A740-2.2K-CHT

  • Country of origin:Egyesült Államok

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 4000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Regulating industrial motor speed with exceptional torque control, the Mitsubishi Electric FR-A740-2.2K-CHT is a high-performance three-phase 400V variable frequency drive designed for heavy-duty applications. Part of the robust FR-A700 Series, this 2.2 kW (3 HP) inverter features advanced magnetic flux vector control and real sensorless vector control, ensuring stable speed regulation even at ultra-low frequencies. Engineered to survive harsh manufacturing environments, it serves as an essential automation component for precise machinery synchronization, fan/pump speed regulation, and torque-limiting applications.

Key Features

  • Real Sensorless Vector Control (RSV): Achieves high-accuracy torque and speed control without requiring an encoder feedback interface.
  • Offline Auto-Tuning: Automatically characterizes motor parameters to maximize performance across different motor brands.
  • Built-In Modbus RTU: Integrated RS-485 serial communication port supports standard industrial networking protocols.
  • Long-Life Design: Utilizes specialized cooling fans and capacitors rated for extended service lifetimes.
  • Integrated PLC Functionality: Allows custom logic control processing directly inside the drive using GX Developer software.

Applications

  • Conveyors and material handling distribution systems requiring high starting torque.
  • Industrial fan, blower, and exhaust ventilation systems.
  • Centrifugal pumps, booster stations, and fluid processing facilities.
  • Machine tool spindles, textile winding machines, and packaging equipment.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Mitsubishi Electric
Model Number FR-A740-2.2K-CHT
Product Series FR-A700 (A740 Class)
Input Voltage / Frequency 3-Phase 380 to 480 V AC, 50Hz / 60Hz
Applicable Motor Capacity 2.2 kW (3 Horsepower)
Output Current Rating 6.0 A (LD) / 5.0 A (HD)
Output Frequency Range 0.2 to 400 Hz
Control Modes Available V/F Control, Advanced Magnetic Flux Vector Control, Real Sensorless Vector Control
Enclosure Rating IP20 (Open Type)
Ambient Operating Temperature -10 to 50 degC (non-freezing)
Terminal Screw Size M3 x 35 mm (Control terminals)
Shipping Weight (Calculated) 4.0 kg (8.82 lbs)

Empirical Engineering Insights

Alternative Models & Compatibility

The FR-A740-2.2K-CHT serves as a direct upgrade to the older FR-A540-2.2K series. For facilities transitioning to the newer FR-A840 series, the FR-A840-00126-2.6K is the designated replacement. When migrating configuration parameters, use the FR Configurator software to import and convert parameter tables seamlessly, but pay special attention to the terminal block mapping if relying on built-in PLC functions.

Application Pitfalls & Engineering Notes

In high-inertia fan applications, decelerating too rapidly can generate regenerative energy back into the drive, triggering an E.OV3 (Overvoltage during deceleration) safety fault. To prevent downtime under high-inertia loads, integrate a dedicated external braking resistor (FR-ABR-H2.2K) and ensure parameter 30 (Regenerative function selection) is configured correctly.

Commissioning & Wiring Tips

Always route the control signal wiring (using shielded twisted pair cables) completely separate from the main motor and power input lines to mitigate electro-magnetic interference (EMI). Terminal connections for control logical inputs are secure-clamp style; avoid using bare stranded copper wires without crimp ferrules, as this can lead to intermittent feedback signals.

Installation Guidelines

CRITICAL ELECTRICAL WARNING

Isolate and lock out all AC main line input feeds before attempting terminal wiring or mounting procedures. Internal DC-bus capacitors retain high-voltage charge after de-energization. Wait at least 10 minutes and verify with a reliable multimeter that the voltage across terminals P/+ and N/- is below 30 V DC before initiating hands-on physical contact.

1

Enclosure Mounting: Mount the inverter vertically onto a flat, non-flammable surface inside an electrical cabinet. Maintain a minimum horizontal spacing clearance of 50 mm and vertical clearance of 100 mm for unrestricted convective heat dissipation.

2

Power Connections: Connect the three-phase AC input supply to terminals R/L1, S/L2, and T/L3. Connect the output motor terminals to U, V, and W. Ensure the grounding terminal (PE) is securely bonded to the plant ground grid.

3

Startup Initialization: Turn on the input power. Set Parameter 9 (Electronic thermal O/L relay) to match the motor's rated plate current before executing any physical rotation tests.

What is the primary function of the CHT suffix on the FR-A740-2.2K-CHT?

The 'CHT' suffix designates a regional variation intended for the Chinese industrial market, utilizing Chinese language instruction material and labeling, while maintaining identical internal hardware, electrical performance, and parameter definitions as standard global FR-A740 models.

Does this model include a built-in dynamic braking transistor?

Yes, the FR-A740-2.2K-CHT contains a built-in braking transistor. However, for applications with high-inertia deceleration or heavy cyclic braking, you must install an external braking resistor across terminals P/+ and PR.

Can this drive run on a single-phase AC input supply?

No. The FR-A740-2.2K-CHT is strictly designed for three-phase AC input power (380 to 480 V AC, 50Hz/60Hz). Attempting to operate this unit on a single-phase source will trigger an input phase failure or under-voltage fault.

How do I clear an E.THT fault code on this inverter?

E.THT indicates an electronic thermal relay function trip (motor overload). Verify that the motor nameplate current matches Parameter 9, check for physical mechanical binding on the motor shaft, and ensure the load does not exceed the continuous output current limit of the drive.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...