ABB ACS580-01-026A-4 ACS580 Variable Frequency Drive

ABB ACS580-01-026A-4 ACS580 Variable Frequency Drive

Hanya 5 item tersisa di stok
  • Produsen: ABB

  • Nomor Produk: ACS580-01-026A-4

  • Negara asal:Swedia

  • Jenis Produk: Variable Frequency Drives

  • Kode batang: 85371091

  • Pembayaran: T/T, Western Union

  • Berat: 6800g

  • Dimensi: 373 x 125 x 223 mm (Height x Width x Depth)

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

Optimized for reliable and efficient motor control in demanding environments, the ABB ACS580-01-026A-4 is an all-compatible, wall-mounted variable frequency drive tailored for variable torque and constant torque applications. Delivering 11 kW (15 HP) of nominal power at 3-phase 400V, this unit optimizes energy consumption while offering effortless system integration. Part of the ACS580 series, it incorporates an integrated control unit, a built-in harmonic choke, and an EMC filter as standard, minimizing external component requirements in standard cabinet configurations.

Key Features

  • Integrated safe torque off (STO) safety function certified to SIL 3 / PL e standards.
  • Built-in C2 category EMC filter and patented switching choke technology to mitigate harmonic distortion.
  • Supports scalar, vector, and permanent magnet motor control modes for highly adaptable process performance.
  • User-friendly assistant control panel equipped with an intuitive interface and micro-USB connectivity.
  • Robust IP21 enclosure rating for standard wall-mounting layout configurations.

Applications

  • Centrifugal pumps, booster systems, and water treatment operations.
  • Industrial ventilation fans, exhaust systems, and air handling systems.
  • Conveyors, packaging lines, and production material handling machinery.
  • Screw compressors and mixers requiring highly regulated motor speed adjustments.

Technical Specifications

Parameter Specification Values
Manufacturer ABB
Model Code ACS580-01-026A-4
Frame Size R2
Nominal Output Current (I_N) 26.0 A
Light Overload Current (I_Ld) 25.0 A
Heavy Duty Current (I_Hd) 17.0 A
Nominal Power (P_N) 11.0 kW (15.0 HP)
Main Input Voltage Range 3-phase 380 to 480 VAC (+10% / -15%)
Enclosure Class IP21 / UL Type 1
Operating Temperature Range -15 to 50 degC (derating applicable above 40 degC)
Analog Inputs 2 x Programmable (voltage or current configuration)
Analog Outputs 2 x Programmable (0 to 20 mA range)
Digital Inputs 6 x Programmable (24 VDC internal/external logic support)
Relay Outputs 3 x Programmable (Form C, 250 VAC / 30 VDC, 2 A max)
Embedded Fieldbus Connection Modbus RTU (EIA-485 interface)
Shipping Weight (Calculated) 6.80 kg (15.0 lbs)
Package Dimensions (Calculated) 373 x 125 x 223 mm (Height x Width x Depth)

Control Connections & Interfaces

Terminal Block Default Signal Assignment Electrical Characteristics
+24V / DGND Auxiliary Voltage Output 24 VDC, max. 250 mA current supply
DI1 Start / Stop Command Digital input, PNP/NPN selection (12 to 30 VDC)
DI2 Forward / Reverse Rotation Digital input, PNP/NPN selection (12 to 30 VDC)
AI1 External Speed Reference Analog input: 0 to 10 V, or 0/4 to 20 mA
OUT1, OUT2, OUT3 Relay Outputs 1 to 3 Changeover contacts, resistive rating 2 A at 250 VAC
OUT4, OUT5 (STO) Safe Torque Off (Dual Channel) SIL 3 compliance, physical safety loop inputs

Empirical Engineering Insights

Alternative Models & Compatibility

The ACS580-01-026A-4 serves as a highly robust replacement pathway for discontinued legacy ACS550-01-023A-4 installations. While it offers identical mounting footprint configurations for standard Frame R2 environments, always verify that external parameter maps (especially those associated with dynamic braking parameters or custom macro configurations) are converted using Drive Composer software prior to field execution.

Application Pitfalls & Engineering Notes

Operating the Frame R2 chassis at environmental ambient temperatures exceeding 40 degC will invoke a linear current derating of 1% per additional 1 degC up to a absolute threshold of 50 degC. To avoid unexpected thermal-related under-voltage or over-current tripping under heavy-duty duty cycles (e.g., loaded conveyors), ensure the ventilation pathways match standard factory clear-space specifications of 150 mm top and bottom clearance.

Commissioning & Wiring Tips

Do not run control cable wires adjacent to high-voltage motor output lines. Always establish 360-degree shielding grounding contacts on all incoming control shield cables directly at the metallic drive gland plate. When using external 24 VDC options, confirm that correct jumper routing has been executed on the control board terminals to prevent ground-loop signal variations.

Installation Guidelines

CRITICAL WARNING: Verify that the main AC power distribution feeding the drive is completely de-energized and locked out. Allow a minimum of 5 minutes after switching off the power input supply to allow the internal DC bus capacitors to fully discharge. Always use an approved digital multimeter to measure DC link terminal voltage (UDC+ to UDC-) to verify the system is at 0V prior to wiring.
1

Mount the R2 frame unit vertically on a flat, non-flammable backplate using standard M5 fastening screws to secure the top and bottom structural tabs.

2

Route the symmetric 3-phase incoming power lines to the input terminals U1, V1, and W1, and ground the incoming PE line to the cabinet chassis ground block.

3

Connect the symmetrical shielded motor cable strictly to terminals U2, V2, and W2. Ensure the copper shield of the motor cable is terminated with a 360-degree clamp at the drive ground bracket.

4

Verify that the Safe Torque Off (STO) jumper wires are properly terminated in terminals OUT4/OUT5 unless external physical dual-channel emergency stop safety relays are connected.

Loading product navigation…

What is the standard frame size for the ACS580-01-026A-4 drive?

This model belongs to the Frame R2 class of wall-mounted variable frequency drives.

Does this drive include a built-in harmonic mitigation component?

Yes, it is equipped with a built-in choke and an integrated EMC C2 category filter as standard equipment.

What are the safe torque off (STO) specifications for this drive?

It features integrated dual-channel Safe Torque Off (STO) terminals designed to meet SIL 3 (EN/IEC 61508) and PL e (EN ISO 13849-1) safety standards.

Is derating required for high operating temperatures?

Yes. No current derating is required for ambient temperatures up to 40 degC. Between 40 degC and 50 degC, output current must be derated by 1% per additional degC.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Swedia

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...