1 dari 1

ABB AI845 3BSE023675R1 S800 I/O Analog Input Module

ABB AI845 3BSE023675R1 S800 I/O Analog Input Module

Hanya 2 item tersisa di stok
  • Produsen: ABB

  • Nomor Produk: 3BSE023675R1

  • Negara asal:Swedia

  • Jenis Produk: Analog Input Modules

  • Kode batang: 85389091

  • Pembayaran: T/T, Western Union

  • Berat: 250g

  • Dimensi: 25 x 12 x 10 cm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

The AI845 with product ID 3BSE023675R1 is an 8-channel analog input module designed for the S800 I/O distributed system architecture. This hardware unit interfaces standard 0 to 20 mA or 4 to 20 mA current signals from field transmitters directly to the central processing controller. It incorporates dedicated HART routing capabilities per channel, enabling bi-directional communication with smart instruments over existing analog loops without altering regular process variable transmission. It provides dual-channel hardware redundancy options when paired with appropriate terminal units, maintaining active signal paths and system availability during single module exceptions.

Features

  • Provides 8 single-ended current tracking input channels supporting 0 to 20 mA or 4 to 20 mA signals.
  • Integrates channel-by-channel HART pass-through communication for asset management systems.
  • Supports hot-swapping and fully redundant configurations for uninterrupted process data acquisition.
  • Features integrated diagnostic routines to supervise open-circuit monitoring and out-of-range signal states.
  • Utilizes compact electrical termination setups using standard S800 Module Termination Units.

Applications

  • High-availability process loop telemetry inside petrochemical refining and power generation units.
  • Dual-fault tolerant interface links interfacing safety parameters with distributed control systems.
  • Asset management integration utilizing remote HART diagnostic mapping protocols.

Technical Specifications

Parameter Value
Manufacturer ABB
Model AI845
Product ID 3BSE023675R1
Series S800 I/O
Product Type Analog Input Module
Number of Channels 8 single-ended channels (redundancy supported)
Input Range 0 to 20 mA / 4 to 20 mA
Input Impedance 250 ohms
Resolution 12-bit A/D conversion
HART Protocol Support Yes, pass-through per channel
Power Requirements 24 V DC internal consumption
Degree of Protection IP20
Operating Temperature 0 to +55 degC
Storage Temperature -40 to +70 degC
Country of Origin Sweden (SE)
Weight 0.25 kg

Connections/Interfaces

Terminal Pin Function
1 Channel 1 Signal Input (+)
2 Channel 2 Signal Input (+)
3 Channel 3 Signal Input (+)
4 Channel 4 Signal Input (+)
5 Channel 5 Signal Input (+)
6 Channel 6 Signal Input (+)
7 Channel 7 Signal Input (+)
8 Channel 8 Signal Input (+)
9 to 16 Channel Signal Return / Common Ground (0V)

Installation Guidelines

  • Baseplate Insertion: Verify that the Module Termination Unit (such as TU844 or TU845) is secured onto the DIN rail before engaging the module body. Disconnect primary electrical feeds, align the plastic guide tabs, and apply uniform vertical force until the side retention latches click home.
  • Shielding Protocol: Terminate the outer metal mesh of twisted-pair instrument wires using the ground bars situated on the enclosure entry frame. Maintain single-point earth terminations at the control cabinet wall to eliminate low-frequency ground-loop feedback.
  • Redundant Configuration: To execute redundant module deployments, both units must reside in an identical, paired-slot termination cluster. Map the master/backup hierarchy inside the control programming software to handle hot-standby functions.
  • Cable Separation Routing: Route low-current operational signals in separate wiring ducts isolated from variable speed drives, bulk contactor control blocks, and heavy three-phase power buses by a minimal clear air threshold of 30 cm.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB AI845 3BSE023675R1 S800 I/O Analog Input Module

Does this module supply transmitter loop power directly to 2-wire instruments?

This module acts as a current-sinking input device. Loop voltage for 2-wire transmitters must be supplied through an external 24 V DC distribution block or specialized module termination units containing integrated auxiliary distribution.

What happens to the process variable measurement if one module in a redundant pair fails?

The backplane interface switches the active signal processing path to the standby partner within milliseconds without interrupting the data stream or generating process value spikes.

Can standard 0 to 5 V or 0 to 10 V voltage inputs connect to this card?

No. This module is exclusively designed to evaluate current loop paths within the 0 to 20 mA or 4 to 20 mA operational signal ranges.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Color pattern
Putih
Country of origin
Swedia
Power source
Daya DC

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...