1 dari 6

ABB TU810V1 3BSE013230R1 S800 I/O Compact Module Termination Unit

ABB TU810V1 3BSE013230R1 S800 I/O Compact Module Termination Unit

Hanya 5 item tersisa di stok
  • Produsen: ABB

  • Nomor Produk: 3BSE013230R1

  • Negara asal:Swedia

  • Jenis Produk: Compact Module Termination Units

  • Kode batang: 85389091

  • Pembayaran: T/T, Western Union

  • Berat: 200g

  • Dimensi: 165 mm x 45 mm x 72 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

Serving as a robust connection interface within the S800 I/O distributed automation architecture, the ABB TU810V1 (part number 3BSE013230R1) acts as a compact module termination unit designed to route signals reliably between field wiring and active I/O process modules. This unit accommodates up to 16 independent channels, operating at a maximum rating of 50V, making it a critical component for high-density cabinet layouts where footprint optimization is vital.

Features

  • High-Density Compact Footprint: Allows direct horizontal or vertical DIN-rail mounting to minimize cabinet space requirements.
  • 16-Channel Configuration: Routes up to 16 individual I/O channels alongside dual process voltage connections.
  • Mechanical Coding Keys: Prevents mismatched module insertion, safeguarding the active electronics from field configuration errors.
  • Integrated Modulebus Link: Seamlessly transfers signals and power to adjacent units without external jumper cables.
  • Dual Voltage Distribution: Includes 2 isolated groups with commoned terminal distribution points.

Applications

  • Advant OCS and System 800xA distributed control architectures.
  • Petrochemical, power generation, and water treatment field-instrumentation processing.
  • High-density electrical marshaling cabinets and field junction boxes.

Technical Specifications

Parameter Specification Value
Manufacturer ABB
Model Designation TU810V1
Product ID / SKU 3BSE013230R1
Series S800 I/O
Type Compact Module Termination Unit (MTU)
Number of Channels 16 channels
Rated Voltage 50 V DC / AC maximum
Rated Current 3 A per channel maximum
Connection System Single-wire screw clamp terminals
Conductor Size 0.2 to 2.5 mm² (24 to 14 AWG)
Modulebus Load Negligible (passive routing)
Dimensions (H x W x D) 165 mm x 45 mm x 72 mm
Weight 0.20 kg
Commodity Code 85389091

Connections and Interfaces

Terminal / Connector Point Function / Circuit Assignment
Terminals 1 to 16 I/O Channel connections (Signals 1 to 16)
Terminals 17 & 18 Process Voltage Common 1 (distribution bus)
Terminals 19 & 20 Process Voltage Common 2 (distribution bus)

Empirical Engineering Insights

Alternative Models & Compatibility

The TU810V1 serves as a direct, drop-in evolution of the legacy TU810 compact MTU. The V1 variant features improved thermal tolerance and mechanical housing updates, ensuring absolute backward-compatibility with all existing S800 I/O modules that require a 50V connection interface. If upgrading from non-V1 units, no software modifications or engineering changes are required in the System 800xA or Control Builder environments.

Application Pitfalls & Engineering Notes

While rated for 50V operational limits, designers must verify that the total accumulated current across all 16 connected channels does not exceed the capacity of the power distribution source. In highly compact enclosures, field wiring must be routed systematically to prevent localized heating near the screw terminals, which could accelerate degradation of the adjacent active I/O modules.

Commissioning & Wiring Tips

To ensure noise immunity in electromagnetic interference (EMI) heavy environments, signal cables should be shielded up to the cabinet entrance, and shields must be grounded to a designated bar separate from the MTU. Ensure that the plastic coding keys on the MTU base are properly configured to match the corresponding module type before power-up to prevent physical component damage during hot-swapping procedures.

Installation Guidelines

CRITICAL WARNING: Complete physical isolation and de-energization of the field supply and Modulebus backplane are mandatory before mounting, unmounting, or wiring the MTU. Failure to isolate power may cause electrical arcing, module destruction, or hazardous field conditions.
1

Mount the TU810V1 MTU onto a grounded 35mm horizontal DIN rail by latching the top groove and snapping the lower locking tab onto the rail.

2

Slide the unit laterally along the DIN rail to connect its Modulebus port directly to the adjacent MTU/Modulebus optical port, ensuring the connection latches completely.

3

Strip field signal and distribution wires to 6mm, insert them into the screw terminals (terminals 1-20), and torque them uniformly to 0.5 Nm.

4

Configure the physical mechanical coding keys on the MTU surface to correspond with the targeted I/O module type before docking the electronic module.

Loading product navigation…

What is the primary difference between the TU810 and the TU810V1?

The TU810V1 features updated high-temperature resistant polymers and optimized internal routing traces, offering 100% direct drop-in backward compatibility with older legacy TU810 models.

Does this termination unit support live module hot-swapping?

Yes. S800 I/O modules can be plugged in or unplugged under power from the MTU, provided active loop safety processes permit the live intervention.

What is the maximum torque rating for the field wiring terminals?

The field screw clamp terminals on this MTU should be tightened to a maximum torque specification of 0.5 Nm to prevent mechanical stress on the printed circuit board.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Swedia

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...