1 dari 1

BECKHOFF BK1120 EtherCAT Bus Coupler

BECKHOFF BK1120 EtherCAT Bus Coupler

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: BK1120

  • Negara asal:Jerman

  • Jenis Produk: EtherCAT Bus Couplers

  • Pembayaran: T/T, Western Union

  • Berat: 150g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed to bridge the gap between high-speed EtherCAT networks and standard K-bus assemblies, the BK1120 serves as an efficient communication interface for modular automation systems. This bus coupler maps the technical signals from standard Beckhoff Bus Terminals directly into the EtherCAT protocol, enabling seamless integration into distributed control architectures without sacrificing legacy terminal compatibility.

The BK1120 establishes a high-performance link between physical I/O points and the controller. It automatically handles the conversion of process data and local bus diagnostic information, presenting it clearly to the EtherCAT master. With dual RJ45 interfaces, this module supports flexible line and daisy-chain topologies, simplifying field wiring and reducing installation costs in complex control environments.

Features

  • Direct integration of standard K-bus terminals into high-speed EtherCAT networks.
  • Supports up to 64 standard Bus Terminals directly, and up to 255 Bus Terminals using K-bus extensions.
  • Equipped with two RJ45 ports for line topology networking up to 100 meters apart.
  • High-density data handling with up to 1024 bytes of input and 1024 bytes of output process data.
  • Integrated diagnostic LEDs for quick monitoring of power status, K-bus run, and network communication.

Applications

  • Industrial machinery and high-speed packaging lines.
  • Distributed I/O architectures in processing and manufacturing systems.
  • Retrofitting existing legacy K-bus terminal configurations to modern EtherCAT masters.
  • Building automation and HVAC control infrastructure requiring high-density point aggregation.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model BK1120
Product Type EtherCAT Bus Coupler for standard Bus Terminals
Number of Bus Terminals 64 (up to 255 with K-bus extension)
Max. Process Data Space 1024 bytes input / 1024 bytes output
Bus Interface 2 x RJ45
Distance Between Stations Max. 100 m (100BASE-TX)
Power Supply 24 V DC (-15 % / +20 %)
Input Current 70 mA + (total K-bus current)/4 (500 mA max.)
Starting Current Approx. 2.5 x continuous current
Current Supply K-Bus 1750 mA
Power Contacts Max. 24 V DC / Max. 10 A
Recommended Fuse <= 10 A
Electrical Isolation 500 V (power contact / functional ground / K-bus)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, no condensation
Weight Approx. 0.15 kg

Connections and Interfaces

Interface Type Function
RJ45 Port 1 (IN) EtherCAT signal input connection from previous station or master
RJ45 Port 2 (OUT) EtherCAT signal output connection to next station in daisy-chain
Spring Force Terminals 24 V DC power supply input and power contact distribution feed

Installation Guidelines

  • Mounting: Install on a standard 35 mm DIN rail (EN 60715). Ensure the mounting slide latches firmly onto the rail.
  • Cabling: Use category 5e (or higher) shielded Ethernet cables to guarantee proper signal integrity and noise immunity.
  • Grounding: Ensure the DIN rail is reliably connected to a low-impedance functional earth grounding point.
  • Power Supply Routing: Keep power lines as short as possible and separate them from high-frequency signal cables to prevent interference.
Loading product navigation…

What is the maximum number of Bus Terminals supported by the BK1120?

The BK1120 directly supports up to 64 standard Bus Terminals. If a K-bus extension is used, this capacity can be expanded up to 255 terminals.

What Ethernet cables should be used with the BK1120?

It is recommended to use Cat5e (or higher) shielded twisted pair (STP) Ethernet cables to ensure reliable high-speed data transmission over EtherCAT.

What is the maximum current capacity supplied to the K-bus by the BK1120?

The BK1120 provides a maximum current supply of 1750 mA to the internal K-bus for attached terminals.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...