Beckhoff CX8050 CX8000 Series Embedded PC with CANopen Master

Beckhoff CX8050 CX8000 Series Embedded PC with CANopen Master

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: CX8050

  • Negara asal:Jerman

  • Jenis Produk: Embedded PCs

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: 64 mm x 100 mm x 73 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

Designed to integrate seamlessly into modular control architectures, the Beckhoff CX8050 serves as a compact, DIN-rail-mountable controller featuring an integrated CANopen master interface. This high-performance device is powered by a 400 MHz ARM9 processor and executes control logic via TwinCAT 2, allowing for highly efficient decentralized processing. Engineered with automatic recognition for both E-bus and K-bus terminal networks, this embedded PC provides a flexible path for interfacing local physical inputs and outputs directly with a CANopen fieldbus trunk. The inclusion of a robust 1-second UPS guarantees the secure storage of critical non-volatile application data onto the 512 MB microSD card in the event of power interruption.

Features

  • Integrated CANopen Master: Dedicated 9-pin D-sub fieldbus interface with galvanic isolation for reliable communication across industrial networks.
  • Dual Bus Auto-Detection: Automatic runtime recognition of connected E-bus (EtherCAT) or K-bus (standard Beckhoff Bus Terminals) interfaces.
  • Non-Volatile Data Protection: Capacitive 1-second UPS preserves up to 1 MB of critical persistent variable data to flash storage during unexpected power loss.
  • Flexible Memory Options: Equipped with a 512 MB microSD flash card, expandable to support larger local visualization files or log databases.
  • Embedded Architecture: Runs Windows Embedded CE 6 for deterministic, low-latency execution of industrial automation logic.

Applications

  • Distributed Fieldbus Control: Serving as a primary gateway or master controller in industrial installations utilizing CANopen-compliant drives, sensors, and remote I/O blocks.
  • Modular Machine Building: Ideal for packaging, assembly, and conveyor systems requiring localized control units that seamlessly bridge distinct communication layers.
  • Hazardous Area Deployments: Rated for demanding physical conditions under ATEX, IECEx, and Class I Division 2 safety standards.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation GmbH & Co. KG
Model CX8050
Processor Type ARM9, 400 MHz (Single Core)
Main Memory 64 MB DDR2 RAM (non-expandable)
Flash Storage 512 MB microSD (optionally expandable)
Persistent Memory 1-second UPS (stores up to 1 MB persistent data)
Operating System Windows Embedded CE 6
Programming Environment TwinCAT 2 PLC (IEC 61131-3 languages)
Integrated Bus Interface 9-pin D-sub (CANopen protocol, galvanically isolated)
I/O Compatibility E-bus (EtherCAT) or K-bus (Bus Terminals) with auto-recognition
E-bus/K-bus Power Supply Limit 2 A
Max. Power Consumption 3 W
Physical Ports 1 x RJ45 (10/100 Mbit/s), 1 x USB interface (behind maintenance flap)
Diagnostics Indicators 1 x TwinCAT Status LED, 2 x Bus Status LEDs
Environmental Operating Temperature 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Relative Humidity Range 95% maximum, non-condensing
Ingress Protection Rating IP20
Physical Weight 180 g
Dimensions (Width x Height x Depth) 64 mm x 100 mm x 73 mm
Shipping Weight (Calculated) 2 kg

Connections and Interfaces

Connector / Terminal Function / Circuit Assignment
RJ45 Port 10/100 Mbit/s Ethernet connection for local programming, parameterization, and network synchronization.
D-sub Port (9-Pin, Male) Dedicated CANopen master physical interface according to CANopen electrical and mechanical standards.
USB Device (Behind Flap) Service and backup deployment interface; accessible behind the lower front protective flap.
I/O Slide Contacts Direct contact slides supporting up to 2 A power injection for E-bus (EtherCAT) or K-bus (Bus Terminals) assemblies.

Empirical Engineering Insights

Alternative Models & Compatibility

The CX8050 belongs strictly to the TwinCAT 2 programming landscape. It does not support TwinCAT 3 runtimes. For newer configurations that demand TwinCAT 3 support or multicore ARM performance, systems should consider migrating toward the Beckhoff CX8190 series, which also incorporates newer operating system configurations such as Windows Embedded Compact 7.

Application Pitfalls & Engineering Notes

The built-in 1-second UPS utilizes internal capacitive storage to safely write persistent variables to the microSD card. If the operating system or system configuration is constantly cycling power, ensure that the controller runs continuously for at least two minutes between power downs. Rapid, back-to-back power cycling will deplete the capacitive backup reservoir, preventing the persistent data block from saving correctly during the second cycle and potentially leading to parameter initialization errors.

Commissioning & Wiring Tips

When establishing a physical connection on the 9-pin D-sub CANopen trunk, remember that terminating resistors are not integrated into the hardware interface. A 120-ohm terminating resistor must be connected externally at both ends of the CAN bus trunk line to minimize signal reflections and ensure operational stability. When mixing or switching terminal types, remember that K-bus and E-bus modules cannot be mixed arbitrarily on the same segment without terminal bus coupling modules.

Installation Guidelines

CRITICAL WARNING:

Always de-energize the entire control panel prior to mounting, dismounting, or routing cable connections to the controller or adjacent terminals. Failure to disconnect primary and auxiliary power systems may result in physical damage to the E-bus/K-bus internal slide contacts and ruin connected input/output modules.

1
Snap the controller housing securely onto a standard 35 mm DIN rail (EN 60715), ensuring the locking mechanism clicks into position.
2
Align and slide the subsequent K-bus or E-bus I/O modules directly onto the right side of the controller until the lateral plug connectors engage properly.
3
Connect the 9-pin CANopen D-sub bus cable to the isolated interface and terminate the physical fieldbus loop using external 120-ohm termination resistance.
4
Apply 24 VDC control power directly to the terminal supply points, allowing the integrated auto-recognition protocol to sequence and detect the I/O configuration.
Loading product navigation…

Can the CX8050 run TwinCAT 3 projects?

No. The CX8050 is designed exclusively for the TwinCAT 2 runtime environment running on Windows Embedded CE 6. If TwinCAT 3 is required, you must migrate to a newer controller family such as the CX8190.

How does the CX8050 handle mixed E-bus and K-bus terminals?

The CX8050 features automated slide contact recognition. It automatically identifies whether E-bus (EtherCAT) or K-bus (standard terminals) are attached at startup. Note that you cannot mix the two terminal families in a single local stack without an appropriate interface coupler.

What happens to the retained control data during a power failure?

The CX8050 features an integrated capacitive 1-second UPS. In the event of a power loss, this energy reservoir provides sufficient runtime to write up to 1 MB of designated persistent variable data securely onto the microSD card.

Are termination resistors integrated into the CANopen interface?

No, the CX8050 does not feature internal software-selectable termination. Standard external 120-ohm terminating resistors must be installed at the two outermost physical ends of your CANopen bus line.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...