Designed for high-precision temperature sensing in distributed control architectures, the Beckhoff EJ3202 is a dual-channel EtherCAT plug-in module designed for direct mounting on application-specific signal distribution boards. This space-saving module enables direct connection of Resistance Temperature Detectors (RTD) using 2-wire or 3-wire cabling methods. By supporting a broad range of RTD sensors like Pt100, Pt1000, and Ni100, the module delivers highly accurate temperature measurement capabilities directly into the EtherCAT communication network, making it highly suitable for demanding industrial machinery and automation environments.

Features

  • Two independent channels for RTD input.
  • Supports 2-wire and 3-wire connection configurations (2-wire as default).
  • Compatible with a wide array of temperature sensors: Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, and KTY sensors.
  • Integrated digital filter and configurable limit value monitoring for enhanced process control.
  • Direct installation onto EJ-series signal distribution boards, minimizing wiring complexity and footprint.
  • Provides 500 V electrical isolation between the E-bus and field potential.

Applications

  • Machinery and equipment manufacturing with customized signal boards.
  • Industrial furnace and HVAC control systems.
  • Process manufacturing requiring precise thermal profiling.
  • Food and beverage production lines requiring clean, distributed I/O installations.

Technical Specifications

Manufacturer Beckhoff
Part Number / Model EJ3202
Technology Temperature measurement (RTD)
Number of Inputs 2
Connection Method 2- or 3-wire (default: 2-wire)
Sensor Types Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, resistance measurement (e.g. potentiometer 10 Ohm to 1/4 kOhm), KTY sensors
Measuring Range -200 to +850 degC (Pt sensors); -60 to +250 degC (Ni sensors)
Resolution 0.1 degC per digit
Measurement Error / Uncertainty < +/-0.5 degC for Pt sensors
Input Filter Limit Frequency typ. 1 kHz
Conversion Time approx. 85 ms default setting (2 to 800 ms configurable)
Power Supply via the E-bus
Current Consumption E-bus typ. 165 mA
Electrical Isolation 500 V (E-bus/field potential)
Special Features Integrated digital filter, limit value monitoring, variable connection technology
Weight approx. 30 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, non-condensing
EMC Immunity/Emission Conforms to EN 61000-6-2/EN 61000-6-4
Vibration/Shock Resistance Conforms to EN 60068-2-6/EN 60068-2-27
Protection Rating IP20

Installation Guidelines

  • Mounting: Ensure the module is properly plugged into the matching application-specific signal distribution board. Confirm latching mechanism is secure before powering the system.
  • Wiring: For 3-wire connections, ensure all lead wires have equal resistance to minimize measuring errors. Keep sensor cables separate from high-voltage motor cables to prevent electromagnetic noise coupling.
  • Thermal Management: Maintain standard operating ambient temperature range of -25 to +60 degC. Ensure adequate clearance for convection cooling inside the enclosure.
  • Grounding: Connect shielding of the RTD cables directly to the ground bus at the entry point of the control panel to minimize external interference.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What sensor types are compatible with the Beckhoff EJ3202?

The EJ3202 supports a wide variety of RTD sensors, including Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, KTY sensors, and general resistance measurements (such as potentiometers ranging from 10 Ohm to 1/4 kOhm).

Does the EJ3202 module support 3-wire RTD measurements?

Yes, the EJ3202 supports both 2-wire and 3-wire connection methods. By default, the module is configured for 2-wire connection technology.

What is the typical measurement accuracy of the EJ3202 when using Pt sensors?

The measurement error or uncertainty for the EJ3202 when utilizing standard Pt sensors is less than +/-0.5 degC.

What is the operating temperature range for the Beckhoff EJ3202 plug-in module?

The EJ3202 is rated for an operating temperature range of -25 to +60 degC and a storage temperature range of -40 to +85 degC.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...