Beckhoff EL2124 EtherCAT Terminal 4-channel Digital Output Module

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: EL2124

  • Negara asal:Jerman

  • Jenis Produk: EtherCAT Terminal Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 150 mm x 120 mm x 40 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Integrating directly into high-speed automation architectures, the Beckhoff EL2124 provides fast, precise digital control over four independent 5 V DC channels. Engineered for rapid switching dynamics, this EtherCAT Terminal utilizes a CMOS push-pull output design capable of actively sourcing and sinking up to 20 mA per channel. Ideal for interfacing with low-voltage logic levels, optocouplers, and high-frequency digital receivers, the module features sub-microsecond propagation delays to ensure real-time response times within critical control loops.

Key Features

  • High-Speed Signal Processing: Sub-microsecond switching times (typically under 1 us for both turn-on and turn-off phases) designed for time-critical motion and gating control.
  • Four CMOS Push-Pull Outputs: Supports active high and active low signaling, providing a robust 5 V DC logic driving capacity.
  • Integrated Short-Circuit Protection: Ruggedized engineering design protects the module against wiring faults and overcurrent conditions on all output channels.
  • Comprehensive Galvanic Isolation: 500 V electrical isolation between the E-bus and the field potential safeguards upstream backplane communications.

Industrial Applications

  • High-frequency optocoupler and pulse receiver interfacing
  • Low-voltage logic level shifting and micro-controller integration
  • High-speed material sorting, triggering, and gating systems
  • Testbench automation and electronic hardware-in-the-loop (HIL) simulations

Technical Specifications

Specification Parameter Technical Value
Manufacturer Beckhoff
Model Series EtherCAT Terminal (EL Series)
Number of Outputs 4 channels
Nominal Output Voltage 5 V DC
Output Driver Type CMOS push-pull (source/sink)
Maximum Output Current +/- 20 mA per channel (short-circuit proof)
Switching Propagation Delay TON < 1 us, TOFF < 1 us
Current Consumption (E-bus) Typically 130 mA
Current Consumption (Power Contacts) Typically 12 mA + load
Electrical Isolation 500 V (E-bus to field potential)
Load Type Compatibility Ohmic, lamp load
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC
Relative Humidity 95%, non-condensing
Connection Technology 2-wire or 3-wire direct connection
Connection Cross-Section (Solid/Stranded) 0.08 mm2 to 2.5 mm2 (AWG 28 to 14)
Connection Cross-Section (Ferrule) 0.14 mm2 to 1.5 mm2 (AWG 26 to 16)
Ingress Protection Rating IP20 (conforms to EN 60529)
Ex Marking / Hazardous Location II 3 G Ex nA IIC T4 Gc
Country of Origin Germany
Physical Dimensions Width: 12 mm
Height: 100 mm
Depth: 68 mm
Shipping Weight (Calculated) 0.15 kg
Package Dimensions (Calculated) 150 mm x 120 mm x 40 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The terminal integrates directly into standard TwinCAT 2.x and 3.x system structures. While utilizing the same physical footprint as typical 24 V DC terminals, the unit requires dedicated 5 V DC logic-side distribution. Ensure that any downstream configurations do not inadvertently route field voltages above the rated 5 V threshold to this module.

Application Pitfalls & Engineering Notes

Because this module utilizes standard CMOS push-pull outputs, it actively drives the signaling line both high and low. Avoid connecting multiple output channels in parallel to boost current driving capabilities, as minor switching delays between channels can induce transient short circuits. Additionally, verify the E-bus power supply margins of your coupler segment; a single terminal consumes 130 mA typical E-bus current.

Commissioning & Wiring Tips

For signal transmission distances exceeding 3 meters, shielded twisted-pair cabling is strongly recommended to minimize environmental electromagnetic interference. Ground the cable shield securely at the control panel boundary plate to isolate high-speed CMOS switching channels from structural floor noise.

Installation Guidelines

CRITICAL WARNING:

De-energize the entire control system and disconnect all field power contacts before installing, servicing, or extracting any EtherCAT terminal. Failure to do so can result in electrical arcing, destruction of sensitive CMOS drivers, or transmission faults across the adjacent E-bus.

1
Mount the terminal onto a standard 35 mm DIN rail (conforming to EN 60715) and verify that the locking mechanism engages securely with the rail profile.
2
Align adjacent terminals using the side-by-side double slot and key connection, checking that the internal gold E-bus contact pins connect smoothly without mechanical force.
3
Strip wiring insulation to exactly 8-9 mm. Actuate the internal spring clamp using a flat-head screwdriver, insert the solid or ferruled conductor, and release the tool to clamp.
4
Power up the segment and initiate terminal detection and routing parameters using the TwinCAT System Manager software tree.
Loading product navigation…

Can this terminal drive 24 V DC actuators directly?

No. The terminal provides active 5 V DC CMOS push-pull signals up to 20 mA. Connecting this module directly to 24 V DC systems will permanently damage the internal output drivers.

What is the primary benefit of the CMOS push-pull output design on this module?

The push-pull design actively sources and sinks current, facilitating sub-microsecond transition times (under 1 microsecond). This eliminates signal float and ensures sharp voltage edges suitable for fast logic and optocouplers.

How are wiring terminations made on this terminal block?

The terminal utilizes a spring clamp mechanism. Depress the spring actuator using a standard flat-head screwdriver, insert a stripped wire (8 to 9 mm stripping length), and release the tool to establish a vibration-resistant connection.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...