1 dari 1

Beckhoff EP1957-0022 TwinSAFE EtherCAT Box Module

Beckhoff EP1957-0022 TwinSAFE EtherCAT Box Module

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: EP1957-0022

  • Negara asal:Jerman

  • Jenis Produk: TwinSAFE Safety Modules

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Serving as a direct, rugged link between safe input and output field signals, the Beckhoff EP1957-0022 enables decentralized safety logic execution within automated machinery. This IP67-rated TwinSAFE EtherCAT Box integrates safety inputs, safety outputs, and a local programmable safety controller into a single, compact field device. By mounting directly on the machine outside of control cabinets, the Beckhoff EP1957-0022 minimizes field-wiring complexity while maintaining compliance with strict global machine safety directives.

Features

  • Integrated Safety Logic: Supports localized safety PLC program execution via Safety over EtherCAT (FSoE).
  • IP67 Protection: Dust-tight and water-resistant enclosure engineered for direct machine mounting without an enclosure.
  • Flexible Signal Count: Equipped with 8 safe inputs and 4 safe outputs to manage local safety loops.
  • M12 Connection Technology: Uses standardized M12 5-pin, A-coded connection terminals for secure sensor/actuator integration.
  • Optimized Form Factor: Dual M8 shielded interfaces for deterministic, high-speed EtherCAT communication.

Applications

  • Decentralized safety monitoring in packaging machinery and material handling systems.
  • Robotic work cells requiring localized emergency stop, light curtain, and safety gate integration.
  • Harsh industrial environments subject to washdown procedures, oil exposure, or fine particulate accumulation.
  • Modular machine configurations where safety zones must operate independently or exchange safe status via FSoE.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model Number EP1957-0022
Protocol TwinSAFE / Safety over EtherCAT (FSoE)
Bus Interface 2 x M8 socket, shielded, screw type
Connection Technology M12 x 1, 5-pin, A-coded
Number of Safe Inputs 8
Number of Safe Outputs 4
Max. Output Current 0.5 A per channel
Cycle Time 1 ms nominal (dependent on safety project size)
Fault Response Time <= parameterized watchdog time
Current Consumption (US) Max. 120 mA
Current Consumption (UP) Max. 60 mA
Protection Rating IP67 (conforms to EN 60529)
Safety Standards EN ISO 13849-1:2015 (Cat. 4, PL e), EN 61508:2010 (SIL 3)
Installation Position Variable / Multi-directional mounting
Unit Weight 315 g
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Connector Type Terminal Definition Functional Assignment
2 x M8 Sockets EtherCAT In / Out Shielded, deterministic industrial communication path
M12 5-Pin (A-coded) Safe Inputs 1 to 8 Dual-channel or single-channel sensor input connections
M12 5-Pin (A-coded) Safe Outputs 1 to 4 0.5 A safe switching signals to actuators/contactors

Empirical Engineering Insights

Alternative Models & Compatibility

The EP1957-0022 operates as a decentralized safety controller. If your architecture relies purely on centralized logic and only requires safety input expansions, consider the EP1908-0002. This module is compatible with TwinCAT 3.1 environments. Be aware that safety checksum modifications require a full download of the safety project via the EtherCAT master; on-the-fly logical modifications are restricted by safety standard requirements.

Application Pitfalls & Engineering Notes

While the safe outputs are rated for 0.5 A, inductive load switching requires external free-wheeling diodes if the internal suppression limits are exceeded during rapid cycles. Additionally, ensure the total current draw of the sensor supply (US) does not exceed 120 mA to prevent local overcurrent trips. When designing the physical layout, avoid mounting the device in direct proximity to high-vibration sources or extreme heat emitters without dynamic heat-sink spacing, as thermal buildup can reduce the operational life of the internal safety relays.

Commissioning & Wiring Tips

Always use high-quality, double-shielded M8 cabling for the EtherCAT network to avoid EMC-induced watchdog timeout errors, which automatically put the safety logic into a safe state. Ensure the metallic mounting brackets of the module are directly grounded to the machine frame to establish a low-impedance path for high-frequency noise. Verify that the US (sensor/control power) and UP (actuator peripheral power) circuits are fed from independent, certified Class 2 power supplies to maintain proper safety isolation.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL SAFETY PROTOCOL

De-energize all primary, auxiliary, and safety-loop power distribution systems before physical installation or cable connection. Verify the complete absence of voltage across all terminals using a calibrated multimeter. Failure to isolate power can result in permanent damage to internal safety components, unexpected machine motion, or severe physical injury.

1

Securely mount the EtherCAT Box to a flat, vibration-damped surface using M4 screws, tightening them to a maximum torque of 1.2 Nm.

2

Attach the shielded M8 EtherCAT communication cables. Hand-tighten the connectors to ensure the IP67 sealing ring is properly compressed.

3

Connect the A-coded M12 cables for the safety inputs and safety outputs according to the safety loop schematic.

4

Verify that all unused M8 and M12 ports are sealed with approved IP67 protective caps to prevent dust and fluid ingress.

5

Apply power to the system, verify network connection status via the LED indicators, and execute a functional safety test of the logic project.

Loading product navigation…

Can the safety logic on this module be programmed independently of the master PLC?

Yes, the module features an integrated TwinSAFE logic processor. While it depends on the EtherCAT network for process image transmission, the safety program execution occurs directly within the local safety processor.

What is the maximum output current limit per channel?

The maximum output current is 0.5 A per safe output channel. If switching inductive loads, ensure proper external suppression is implemented.

How are the dual power feeds (US and UP) isolated within the system?

The US supply powers the internal control electronics and safe inputs, while the UP supply powers the safe output channels. This physical separation prevents short-circuit faults on the output actuators from disabling the module control logic.

What happens if a communication error occurs on the EtherCAT line?

In the event of an EtherCAT or FSoE communication timeout, the module initiates its safety shutdown protocol, forcing all safe outputs to their defined safe de-energized state within the watchdog time limit.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...